SCREEN-PRINTED ELECTRODE MODIFIED WITH SILVER HEXACYANOFERRATE-NAFION® FOR ASCORBIC ACID DETERMINATION

被引:1
作者
Mattos, I. L. [1 ]
Padilla, F. [1 ]
Zagal, J. H. [1 ]
Falcao, E. H. L. [2 ]
Segura, R. [1 ]
机构
[1] Univ Santiago Chile, Fac Quim & Biol, Dept Quim Mat, Sucursal Matucana, Santiago 9170022, Chile
[2] Univ Fed Pernambuco, Dept Quim Fundamental, Recife, PE, Brazil
关键词
Silver hexacyanoferrate; Ascorbic acid; Food and pharmaceutical sample; Re-used screen printed electrodes; Flow amperometry; INJECTION SPECTROPHOTOMETRIC DETERMINATION; LIQUID-CHROMATOGRAPHIC METHOD; PRUSSIAN-BLUE; URIC-ACID; PHARMACEUTICAL FORMULATIONS; CARBON ELECTRODES; NANOTUBES; DOPAMINE; REAGENT; BULK;
D O I
10.4067/S0717-97072011000300018
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A flow injection system using a new and/or re-used graphite screen-printed electrode modified with silver hexacyanoferrate and a Nafion (R) polymer layer (AgHCF/GSPE) was employed for the determination of ascorbic acid in orange juice and drugs samples. Both modified electrodes showed an initial sensitivity of 0.015 A.cm(-2).M-1, with a linear response over the range from 50 to 300 mu L-1, relative standard deviations smaller than 2%, detection and quantification limits of e.a. 5.0 and 25.0 mg.L-1. The response of the electrodes was stable, with no variation of base line after 6-8 hours of continuous operation. With this system it is possible to measure 65-70 samples (20 mu L) per hour. By using 1.06 mg of AgNO3, 4.12 mg of K3Fe(CN)(6), 50.5 meal KNO3, and 800 mu L of HNO3, it is possible to obtain between 25 and 30 modified electrodes. The proposed system showed to be inexpensive, versatile, robust and suitable. for industrial application. The surface morphology of the bare and/or modified graphite screen-printed electrode was characterized by scanning electron microscopy.
引用
收藏
页码:803 / 807
页数:5
相关论文
共 40 条
[1]  
Azevedo W.M., 2008, APPL SURF SCI, V255, P770
[2]  
Bard AJ., 1980, ELECTROCHEMICAL METH
[3]   Flow injection amperometric detection of ascorbic acid using a Prussian Blue film-modified electrode [J].
Castro, SSL ;
Balbo, VR ;
Barbeira, PJS ;
Stradiotto, NR .
TALANTA, 2001, 55 (02) :249-254
[4]  
Cheng Y., 2001, ANAL CHIM ACTA, V435, P351
[5]   Automated determination of glucose in soluble coffee using Prussian blue-glucose oxidase-Nafion® modified electrode [J].
de Mattos, IL ;
Areias, MCD .
TALANTA, 2005, 66 (05) :1281-1286
[6]   Sensor and biosensor based on Prussian Blue modified gold and platinum screen printed electrodes [J].
de Mattos, IL ;
Gorton, L ;
Ruzgas, T .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (2-3) :193-200
[8]   Vitamin C deficiency [J].
Fain, O .
REVUE DE MEDECINE INTERNE, 2004, 25 (12) :872-880
[9]   L-ascorbic acid determination in pharmaceutical formulations using a biosensor based on carbon paste modified with crude extract of zucchini (Cucurbita pepo) [J].
Fatibello, O ;
Vieira, IC .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2000, 11 (04) :412-418
[10]   Development and validation of a liquid chromatographic method for the determination of ascorbic acid, dehydroascorbic acid and acetaminophen in pharmaceuticals [J].
Gioia, M. G. ;
Andreatta, P. ;
Boschetti, S. ;
Gatti, R. .