Renal cortical volume: High correlation with pre- and post-operative renal function in living kidney donors

被引:23
作者
Gardan, Edouard [1 ]
Jacquemont, Lola [2 ,3 ,4 ]
Perret, Christophe [1 ]
Heudes, Pierre-Marie [1 ]
Gourraud, Pierre-Antoine [2 ,3 ,4 ]
Hourmant, Maryvonne [2 ]
Frampas, Eric [1 ]
Limou, Sophie [3 ,4 ,5 ]
机构
[1] CHU, Radiol Dept, Hotel Dieu 1 Pl Alexis Ricordeau, F-44093 Nantes 1, France
[2] CHU, Nephrol Dept, Nantes, France
[3] Univ Nantes, INSERM, CRTI, UMR 1064, Nantes, France
[4] CHU, ITUN, Nantes, France
[5] Ecole Centrale Nantes, Nantes, France
关键词
Living kidney donor; Computed tomography scan; Renal cortical volume; Kidney function; Isotopic measures; Prediction; COMPUTED-TOMOGRAPHY; NUCLEAR-RENOGRAPHY; TRANSPLANTATION; PREDICTION; AGE;
D O I
10.1016/j.ejrad.2017.12.013
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: CT volumetry has previously been proposed as an alternative to scintigraphy for the evaluation of pre-donation split renal function and the prediction of post-donation renal function in living kidney donors. The aim of our study was to retrospectively assess the relevance of three CT volumetry techniques for estimating pre-donation kidney function and predicting the risk for chronic kidney disease (CKD) at 1-year post-nephrectomy in a French cohort of living donors using isotopic measures of kidney function. Methods: Kidney volume was quantified pre-donation for 105 donors using three methods total parenchymal three-dimensional renal volume (3DRV), total parenchymal renal volume contouring (RVCt), and renal cortical volume (RCoV). Subjects also had a 51Cr-EDTA scintigraphy to measure glomerular filtration rate (mGFR) pre-donation and 1-year after donation. For each volume, we tested for association with mGFR using univariate regression models, and computed receiver operating characteristics analyses to assess their predictive potential of post-donation CKD. Results: Our population was composed of healthy subjects, who were predominantly female (69%) with a median age at donation of 51yo. Median mGFR was 102 mL/min/1.73 m(2) at pre-donation and 66 mL/min/1.73 m(2) 1-year after nephrectomy. The pre-donation median volume of the preserved kidney was 156 cm(3), 163 cm(3) and 99 cm(3) for the 3DRV, RVCt and RCoV methods respectively, with a high correlation observed between each technique (R > 0.84). For all methods, total kidney volume was significantly associated with pre-donation mGFR (P < 0.001). Preserved kidney volume was also strongly correlated with post-donation mGFR (P < 0.0001), with the strongest correlation observed for RCoV (R = 0.60 vs. R = 0.39 and R = 0.51 for 3DRV and RVCt, respectively). Finally, the RCoV method yielded the best predictive value of 1-year post-donation CKD (AUC = 0.80 vs. AUC = 0.76 and 0.70 for RVCt and 3DRV, respectively). Conclusions: In our cohort of healthy donors with measured kidney function, cortical volumetry (RCoV) appears as the best volumetric technique to use as a surrogate to scintigraphy for estimating pre-donation split renal function and predicting post-donation renal outcomes.
引用
收藏
页码:118 / 123
页数:6
相关论文
共 25 条
  • [1] CT volumetry is superior to nuclear renography for prediction of residual kidney function in living donors
    Barbas, Andrew S.
    Li, Yanhong
    Zair, Murtuza
    Van, Julie A.
    Famure, Olusegun
    Dib, Martin J.
    Laurence, Jerome M.
    Kim, S. Joseph
    Ghanekar, Anand
    [J]. CLINICAL TRANSPLANTATION, 2016, 30 (09) : 1028 - 1035
  • [2] A simple method to estimate renal volume from computed tomography
    Breau, Rodney H.
    Clark, Edward
    Bruner, Bryan
    Cervini, Patrick
    Atwell, Thomas
    Knoll, Greg
    Leibovich, Bradley C.
    [J]. CUAJ-CANADIAN UROLOGICAL ASSOCIATION JOURNAL, 2013, 7 (5-6): : 189 - 192
  • [3] Correlation between CT-based measured renal volumes and nuclear-renography-based split renal function in living kidney donors. Clinical diagnostic utility and practice patterns
    Diez, Alejandro
    Powelson, John
    Sundaram, Chandru P.
    Taber, Tim E.
    Mujtaba, Muhammad A.
    Yaqub, Muhammad S.
    Mishler, Dennis P.
    Goggins, William C.
    Sharfuddin, Asif A.
    [J]. CLINICAL TRANSPLANTATION, 2014, 28 (06) : 675 - 682
  • [4] Use of computed tomography assessed kidney length to predict split renal GFR in living kidney donors
    Gaillard, Francois
    Pavlov, Patrik
    Tissier, Anne-Marie
    Harache, Benoit
    Eladari, Dominique
    Timsit, Marc-Olivier
    Fournier, Catherine
    Leon, Carine
    Hignette, Chantal
    Friedlander, Gerard
    Correas, Jean-Michel
    Weinmann, Pierre
    Mejean, Arnaud
    Houillier, Pascal
    Legendre, Christophe
    Courbebaisse, Marie
    [J]. EUROPEAN RADIOLOGY, 2017, 27 (02) : 651 - 659
  • [5] Kidney-Failure Risk Projection for the Living Kidney-Donor Candidate
    Grams, Morgan E.
    Sang, Yingying
    Levey, Andrew S.
    Matsushita, Kunihiro
    Ballew, Shoshana
    Chang, Alex R.
    Chow, Eric K. H.
    Kasiske, Bertram L.
    Kovesdy, Csaba P.
    Nadkarni, Girish N.
    Shalev, Varda
    Segev, Dorry L.
    Coresh, Josef
    Lentine, Krista L.
    Garg, Amit X.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2016, 374 (05) : 411 - 421
  • [6] Volume matters: CT-based renal cortex volume measurement in the evaluation of living kidney donors
    Halleck, Fabian
    Diederichs, Gerd
    Koehlitz, Torsten
    Slowinski, Torsten
    Engelken, Florian
    Liefeldt, Lutz
    Friedersdorff, Frank
    Fuller, T. Florian
    Magheli, Ahmed
    Neumayer, Hans-H.
    Budde, Klemens
    Waiser, Johannes
    [J]. TRANSPLANT INTERNATIONAL, 2013, 26 (12) : 1208 - 1216
  • [7] Rapid estimation of split renal function in kidney donors using software developed for computed tomographic renal volumetry
    Kato, Fumi
    Kamishima, Tamotsu
    Morita, Ken
    Muto, Natalia S.
    Okamoto, Syozou
    Omatsu, Tokuhiko
    Oyama, Noriko
    Terae, Satoshi
    Kanegae, Kakuko
    Nonomura, Katsuya
    Shirato, Hiroki
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (01) : 15 - 20
  • [8] Usefulness of Multi-Detector Computed Tomography Scanning as a Replacement for Diethylenetriamine Pentaacetic Acid
    Lee, H. H.
    Han, W. K.
    Kang, S. K.
    Huh, K. H.
    Kim, M. S.
    Kim, S. I.
    Kim, Y. S.
    Yoon, Y. E.
    [J]. TRANSPLANTATION PROCEEDINGS, 2017, 49 (05) : 1023 - 1026
  • [9] Mitsui Y, 2017, CLIN EXP NEPHROL
  • [10] 99mTc-DTPA dynamic SPECT and CT volumetry for measuring split renal function in live kidney donors
    Miyazaki, Chihoko
    Harada, Hiroshi
    Shuke, Noriyuki
    Okizaki, Atsutaka
    Miura, Masayoshi
    Hirano, Tetsuo
    [J]. ANNALS OF NUCLEAR MEDICINE, 2010, 24 (03) : 189 - 195