Development of a prototype gantry system for preclinical x-ray phase-contrast computed tomography

被引:41
|
作者
Tapfer, Arne [1 ,2 ]
Bech, Martin [1 ,2 ]
Pauwels, Bart [3 ]
Liu, Xuan [3 ]
Bruyndonckx, Peter [3 ]
Sasov, Alexander [3 ]
Kenntner, Johannes [4 ]
Mohr, Juergen [4 ]
Walter, Marco [5 ]
Schulz, Joachim [5 ]
Pfeiffer, Franz [1 ,2 ]
机构
[1] Tech Univ Munich, Dept Phys, D-85748 Garching, Germany
[2] Tech Univ Munich, Inst Med Engn IMETUM, D-85748 Garching, Germany
[3] SkyScan, B-2550 Kontich, Belgium
[4] Karlsruhe Inst Technol, Inst Microstruct Technol, D-76344 Karlsruhe, Germany
[5] Microworks, D-76137 Karlsruhe, Germany
基金
欧洲研究理事会;
关键词
x-ray imaging; phase contrast; computed tomography; micro-computed tomography;
D O I
10.1118/1.3644844
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To explore the potential of grating-based x-ray phase-contrast imaging for clinical applications, a first compact gantry system was developed. It is designed such that it can be implemented into an in-vivo small-animal phase-contrast computed tomography (PC-CT) scanner. The purpose of the present study is to assess the accuracy and quantitativeness of the described gantry in both absorption and phase-contrast. Methods: A phantom, containing six chemically well-defined liquids, was constructed. A tomography scan with cone-beam reconstruction of this phantom was performed yielding the spatial distribution of the linear attenuation coefficient mu and decrement delta of the complex refractive index. Theoretical values of mu and delta were calculated for each liquid from tabulated data and compared with the experimentally measured values. Additionally, a color-fused image representation is proposed to display the complementary absorption and phase-contrast information in a single image. Results: Experimental and calculated data of the phantom agree well confirming the quantitativeness and accuracy of the reconstructed spatial distributions of mu and delta. The proposed color-fused image representation, which combines the complementary absorption and phase information, considerably helps in distinguishing the individual substances. Conclusions: The concept of grating-based phase-contrast computed tomography (CT) can be implemented into a compact, cone-beam geometry gantry setup. The authors believe that this work represents an important milestone in translating phase-contrast x-ray imaging from previous proof-of-principle experiments to first preclinical biomedical imaging applications on small-animal models. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3644844]
引用
收藏
页码:5910 / 5915
页数:6
相关论文
共 50 条
  • [31] Evaluation of X-ray phase-contrast imaging with the Medipix
    Bartl, P.
    Michel, T.
    Nachtrab, F.
    Uhlmann, N.
    Anton, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 : S143 - S147
  • [32] Development of phase-contrast X-ray imaging techniques and potential medical applications
    Zhou, Shu-Ang
    Brahme, Anders
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2008, 24 (03): : 129 - 148
  • [33] The characterization of a phase contrast x-ray imaging prototype
    Donovan, Molly
    Zhang, Da
    Chen, Wei R.
    Liu, Hong
    COMPLEX DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS IV, 2007, 6436
  • [34] Development of an X-ray interferometer for high-resolution phase-contrast X-Ray imaging
    Hirano, K
    Momose, A
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1999, 38 (12B): : L1556 - L1558
  • [35] Potential of propagation-based synchrotron X-ray phase-contrast computed tomography for cardiac tissue engineering
    Izadifar, Mohammad
    Babyn, Paul
    Chapman, Dean
    Kelly, Michael E.
    Chen, Xiongbiao
    JOURNAL OF SYNCHROTRON RADIATION, 2017, 24 : 842 - 853
  • [36] Registration of phase-contrast images in propagation-based X-ray phase tomography
    Weber, L.
    Haensch, A.
    Wolfram, U.
    Pacureanu, A.
    Cloetens, P.
    Peyrin, F.
    Rit, S.
    Langer, M.
    JOURNAL OF MICROSCOPY, 2018, 269 (01) : 36 - 47
  • [37] Phase-contrast X-ray imaging of breast
    Keyrilainen, Jani
    Bravin, Alberto
    Fernandez, Manuel
    Tenhunen, Mikko
    Virkkunen, Pekka
    Suortti, Pekka
    ACTA RADIOLOGICA, 2010, 51 (08) : 866 - 884
  • [38] Hard X-ray phase-contrast imaging
    Gao, DC
    Pogany, A
    Stevenson, AW
    Gureyev, T
    Wilkins, SW
    Mai, ZH
    ACTA PHYSICA SINICA, 2000, 49 (12) : 2357 - 2368
  • [39] Truncation Correction for X-ray Phase-Contrast Region-of-Interest Tomography
    Felsner, Lina
    Kaeppler, Sebastian
    Maier, Andreas
    Riess, Christian
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2020, 6 : 625 - 639
  • [40] X-Ray Phase-Contrast Tomography of Renal Ischemia-Reperfusion Damage
    Velroyen, Astrid
    Bech, Martin
    Zanette, Irene
    Schwarz, Jolanda
    Rack, Alexander
    Tympner, Christiane
    Herrler, Tanja
    Staab-Weijnitz, Claudia
    Braunagel, Margarita
    Reiser, Maximilian
    Bamberg, Fabian
    Pfeiffer, Franz
    Notohamiprodjo, Mike
    PLOS ONE, 2014, 9 (10):