A computational approach for the lifetime prediction of cardiovascular balloon-expandable stents

被引:25
作者
Auricchio, F. [1 ]
Constantinescu, A. [2 ]
Conti, M. [1 ]
Scalet, G. [1 ]
机构
[1] Univ Pavia, Dipartimento Ingn Civile & Architettura, I-27100 Pavia, Italy
[2] CNRS, Ecole Polytech, Lab Mecan Solides, UMR 7649, F-91128 Palaiseau, France
基金
欧洲研究理事会;
关键词
Cardiovascular stents; 316L stainless steel; Dang Van fatigue criterion; Fatigue-life assessment; HIGH-CYCLE FATIGUE; CRYSTAL PLASTICITY; CORONARY-ARTERY; FRACTURE; DESIGN; SIZE; DEFORMATION; IMPACT; SCALE;
D O I
10.1016/j.ijfatigue.2015.02.002
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper presents a methodology for the numerical fatigue-life assessment of cardiovascular balloon-expandable stents. The methodology is based on a global computational approach composed of a mechanical finite element analysis, followed by a fatigue analysis. The method is applied to a classical 316L stainless steel coronary stent design (i.e., the Medinol/Boston Scientific NIR (TM) stent). Fatigue criteria based on elastic and plastic shakedown concepts for finite and infinite lifetime are used to predict fatigue crack initiation and are calibrated on experimental data related to 316L stainless steel mu m-size components, manufactured as stents. The results from the fatigue analysis allow to discuss several aspects affecting stent lifetime, such as the applied cyclic loading including systolic diastolic pressurization and bending. The generality of the proposed methodology encourages further investigations of such an approach for its application to other materials or small-scale components. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:69 / 79
页数:11
相关论文
共 50 条
  • [41] Risk factors for permanent pacemaker implantation in patients receiving a balloon-expandable transcatheter aortic valve prosthesis
    Droppa, Michal
    Rudolph, Tanja K.
    Baan, Jan
    Nielsen, Niels-Erik
    Baumgartner, Helmut
    Vendrik, Jeroen
    Froehlich, Maren
    Borst, Oliver
    Woehrle, Jochen
    Gawaz, Meinrad
    Potratz, Paul
    Hack, Luis P.
    Mauri, Victor
    Baranowski, Jacek
    Bramlage, Peter
    Kurucova, Jana
    Thoenes, Martin
    Rottbauer, Wolfgang
    Geisler, Tobias
    HEART AND VESSELS, 2020, 35 (12) : 1735 - 1745
  • [42] Three-Year Outcomes of Balloon-Expandable Transcatheter Aortic Valve Implantation According to Annular Size
    Abushouk, Abdelrahman I.
    Spilias, Nikolaos
    Isogai, Toshiaki
    Kansara, Tikal
    Agrawal, Ankit
    Hariri, Essa
    Abdelfattah, Omar
    Krishnaswamy, Amar
    Reed, Grant W.
    Puri, Rishi
    Yun, James
    Kapadia, Samir
    AMERICAN JOURNAL OF CARDIOLOGY, 2023, 194 : 9 - 16
  • [43] Commissural Alignment After Balloon-Expandable Transcatheter Aortic Valve Replacement Is Associated With Improved Hemodynamic Outcomes
    Raschpichler, Matthias
    Flint, Nir
    Yoon, Sung-Han
    Kaewkes, Danon
    Patel, Chinar
    Singh, Chetana
    Patel, Vivek
    Kashif, Mohammad
    Borger, Michael A.
    Chakravarty, Tarun
    Makkar, Raj
    JACC-CARDIOVASCULAR INTERVENTIONS, 2022, 15 (11) : 1126 - 1136
  • [44] Undersizing but overfilling eliminates the gray zones of sizing for transcatheter aortic valve replacement with the balloon-expandable bioprosthesis
    Patsalis, Polykarpos C.
    Kloppe, Axel
    Plicht, Bjoern
    Schoene, Dominik
    Schiedat, Fabian
    Aweimer, Assem
    Kara, Kaffer
    Haldenwang, Peter Lukas
    Strauch, Justus Thomas
    Buck, Thomas
    Muegge, Andreas
    IJC HEART & VASCULATURE, 2020, 30
  • [45] Asymmetrical Expansion of Balloon-Expandable Transcatheter Aortic Valve Prostheses Implications for Valve Hemodynamic and Clinical Outcomes
    Maznyczka, Annette
    Heg, Dierik
    Tomii, Daijiro
    Nakase, Masaaki
    Baekke, Pernille Steen
    Lanz, Jonas
    Stortecky, Stefan
    Reineke, David
    Windecker, Stephan
    Pilgrim, Thomas
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (17) : 2011 - 2022
  • [46] Efficacy and Safety of Postdilatation to Reduce Paravalvular Regurgitation During Balloon-Expandable Transcatheter Aortic Valve Replacement
    Daneault, Benoit
    Koss, Elana
    Hahn, Rebecca T.
    Kodali, Susheel
    Williams, Mathew R.
    Genereux, Philippe
    Paradis, Jean-Michel
    George, Isaac
    Reiss, George R.
    Moses, Jeffrey W.
    Smith, Craig R.
    Leon, Martin B.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (01) : 85 - 91
  • [47] Neosinus and Sinus Flow After Self-Expanding and Balloon-Expandable Transcatheter Aortic Valve Replacement
    Hatoum, Hoda
    Gooden, Shelley C. M.
    Sathananthan, Janarthanan
    Sellers, Stephanie
    Kutting, Maximilian
    Marx, Philipp
    Lilly, Scott M.
    Ihdayhid, Abdul R.
    Thourani, Vinod H.
    Dasi, Lakshmi Prasad
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (24) : 2657 - 2666
  • [48] Balloon-Expandable versus Self-Expandable Valves in Transcatheter Aortic Valve Implantation: Complications and Outcomes from a Large International Patient Cohort
    van Nieuwkerk, Astrid C.
    Santos, Raquel B.
    Andraka, Leire
    Tchetche, Didier
    de Brito, Fabio S.
    Barbanti, Marco
    Kornowski, Ran
    Latib, Azeem
    D'Onofrio, Augusto
    Ribichini, Flavio
    Ten, Francisco
    Dumonteil, Nicolas
    Baan, Jan
    Piek, Jan J.
    Abizaid, Alexandre
    Sartori, Samantha
    D'Errigo, Paola
    Tarantini, Giuseppe
    Lunardi, Mattia
    Orvin, Katia
    Pagnesi, Matteo
    Manuel Nogales-Asensio, Juan
    Ghattas, Angie
    Dangas, George
    Mehran, Roxana
    Delewi, Ronak
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (17)
  • [49] Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Implantation in Patients With Small Aortic Annulus: A Meta-Analysis
    Hosseinpour, Alireza
    Gupta, Rahul
    Kamalpour, Jahangir
    Hosseinpour, Hamidreza
    Chaturvedi, Abhishek
    Agrawal, Ankit
    Patel, Nainesh C.
    Patel, Chirdeep
    AMERICAN JOURNAL OF CARDIOLOGY, 2023, 204 : 257 - 267
  • [50] Anatomical risk models for paravalvular leak and landing zone complications for balloon-expandable transcatheter aortic valve replacement
    Condado, Jose F.
    Corrigan, Frank E., III
    Lerakis, Stamatios
    Parastatidis, Ioannis
    Stillman, Arthur E.
    Binongo, Jose N.
    Stewart, James
    Mavromatis, Kreton
    Devireddy, Chandan
    Leshnower, Bradley
    Guyton, Robert
    Forcillo, Jessica
    Patel, Ateet
    Thourani, Vinod H.
    Block, Peter C.
    Babaliaros, Vasilis
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (04) : 690 - 700