Effectiveness of core-needle US-guided biopsy as a primary tool for diagnosis of thyroid nodules

被引:0
|
作者
Ali, Reda F. [1 ]
Eldwowik, Yasser M. [2 ]
Aouf, Ahmed [1 ]
Hegab, Sherif [3 ]
Abouelnagah, Galal M. [4 ]
机构
[1] Kafrelsheikh Univ, Fac Med, Dept Gen Surg, Kafrelsheikh, Egypt
[2] Al Azhar Univ, Fac Med, Dept Pathol, Assuit Branch, Assiut, Egypt
[3] Alexandria Univ, Fac Med, Dept Intervent Radiol, Alexandria, Egypt
[4] Alexandria Univ, Fac Med, Dept Gen Surg, Alexandria, Egypt
关键词
core-needle biopsy; fine-needle biopsy; thyroid malignancy; thyroid nodules; total thyroidectomy; ASPIRATION; ULTRASOUND; SYSTEM;
D O I
10.4103/ejs.ejs_93_21
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background In many nodular thyroid cases, fine-needle biopsy (FNB) under the guidance of ultrasound (US) has been a primary diagnostic test as it is a safe, minimally invasive method with a low cost. However, it may have "nondiagnostic" aspirates because of the sampling difficulties. On the other hand, a bigger tissue sample is obtained by core-needle biopsy (CNB), which can promote more precise diagnostic results with a reduction of the need for repeated aspiration. Methods In a case-series study, adult patients with suspicious thyroid nodules were assigned to a preoperative diagnosis by both US-guided FNB and CNB with correlation to the final postoperative pathology diagnosis. Results CNB had more accuracy in thyroid malignancy diagnosis (95.8%) than FNB (75%). Nondiagnostic results could be lessened by CNB more than FNB with calculated sensitivities of 70% and 90% and specificities of 80% and 100% for FNB and CNB, respectively. No significant complications resulted while acquiring the samples for both modalities. Conclusion US-guided CNB was more specific than FNB in the diagnosis of thyroid malignancy. A combination of FNB/CNB would be more precise than performing CNB only or FNB in nodular thyroid disease.
引用
收藏
页码:795 / 799
页数:5
相关论文
共 50 条
  • [1] US-guided core-needle biopsy of the thyroid gland
    Screaton, NJ
    Berman, LH
    Grant, JW
    RADIOLOGY, 2003, 226 (03) : 827 - 832
  • [2] Malignant pleural mesothelioma: US-guided histologic core-needle biopsy
    Heilo, A
    Stenwig, AE
    Solheim, OP
    RADIOLOGY, 1999, 211 (03) : 657 - 659
  • [3] Evaluation of Modified Core-Needle Biopsy in the Diagnosis of Thyroid Nodules
    Ahn, Soomin
    Jung, Sejin
    Kim, Ji-Ye
    Shin, Jung Hee
    Hahn, Soo Yeon
    Oh, Young Lyun
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (04) : 656 - 664
  • [4] Complications following US-guided core-needle biopsy for thyroid lesions: a retrospective study of 6,169 consecutive patients with 6,687 thyroid nodules
    Eun Ju Ha
    Jung Hwan Baek
    Jeong Hyun Lee
    Jae Kyun Kim
    Young Jun Choi
    Tae Yon Sung
    Tae Yong Kim
    European Radiology, 2017, 27 : 1186 - 1194
  • [5] Complications following US-guided core-needle biopsy for thyroid lesions: a retrospective study of 6,169 consecutive patients with 6,687 thyroid nodules
    Ha, Eun Ju
    Baek, Jung Hwan
    Lee, Jeong Hyun
    Kim, Jae Kyun
    Choi, Young Jun
    Sung, Tae Yon
    Kim, Tae Yong
    EUROPEAN RADIOLOGY, 2017, 27 (03) : 1186 - 1194
  • [6] Thyroid nodules: Evaluation with US-guided core biopsy with an automated biopsy gun
    Taki, S
    Kakuda, K
    Kakuma, K
    Annen, Y
    Katada, S
    Yamashita, R
    Kosugi, M
    Michigishi, T
    Tonami, N
    RADIOLOGY, 1997, 202 (03) : 874 - 877
  • [7] Core-needle biopsy in thyroid nodules: performance, accuracy, and complications
    Paja, Miguel
    Luis del Cura, Jose
    Zabala, Rosa
    Korta, Igone
    Ugalde, Aitziber
    Lopez, Jose, I
    EUROPEAN RADIOLOGY, 2019, 29 (09) : 4889 - 4896
  • [8] Core-needle biopsy in thyroid nodules: performance, accuracy, and complications
    Miguel Paja
    Jose Luis del Cura
    Rosa Zabala
    Igone Korta
    Aitziber Ugalde
    José I. López
    European Radiology, 2019, 29 : 4889 - 4896
  • [9] Core Needle Biopsy in the Diagnosis of Thyroid Nodules
    Aysan, Erhan
    Guler, Beril
    Kiran, Tugce
    Idiz, Ufuk O.
    AMERICAN SURGEON, 2023, 89 (12) : 5170 - 5174
  • [10] US-guided core needle biopsy of the breast: Technique and pitfalls
    Harvey, JA
    Moran, RE
    RADIOGRAPHICS, 1998, 18 (04) : 867 - 877