Development and validation of analytical methodology for near-infrared conformance testing of pharmaceutical intermediates

被引:13
作者
Forbes, RA
Persinger, ML
Smith, DR
机构
[1] Analytical Development, Lilly Research Laboratories, A Division of Eli Lilly and Company, Clinton
关键词
pharmaceutical analysis; near-infrared spectroscopy; method validation; loracarbef; conformity index; conformance testing; wavelength distance method;
D O I
10.1016/S0731-7085(96)01875-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An approach was developed to create and validate analytical methods to perform near-infrared (NIR) conformance testing on two isolated intermediates used in the manufacture of loracarbef monohydrate bulk drug substance. Method calibration sets were developed from second-derivative NIR reflectance spectra for 30 representative batches of each intermediate. In conformance testing, second-derivative NIR spectra for samples from newly manufactured batches are compared with the calibration set. If the new spectrum is not statistically different to the average of the calibration set, the sample passes the conformance test. Using authentic batch samples of typical and low-potency lots, the methods were validated for accuracy, selectivity, ruggedness and repeatability of the methods.
引用
收藏
页码:315 / 327
页数:13
相关论文
共 10 条
[1]  
Ciurczak E.W., 1986, Spectroscopy, V1, P36
[2]   USES OF NEAR-INFRARED SPECTROSCOPY IN PHARMACEUTICAL ANALYSIS [J].
CIURCZAK, EW .
APPLIED SPECTROSCOPY REVIEWS, 1987, 23 (1-2) :147-163
[3]  
CIURCZAK EW, 1992, HDB NEAR INFRARED AN, pCH20
[4]   CLASSIFICATION OF NEAR-INFRARED SPECTRA USING WAVELENGTH DISTANCES - COMPARISON TO THE MAHALANOBIS DISTANCE AND RESIDUAL VARIANCE METHODS [J].
GEMPERLINE, PJ ;
BOYER, NR .
ANALYTICAL CHEMISTRY, 1995, 67 (01) :160-166
[5]  
HILAEY PA, 1994, NIR MEWS, V5, P10
[6]  
KOHN WH, 1992, J FORENSIC SCI, V37, P35
[7]   SOME APPLICATIONS OF NEAR-INFRARED REFLECTANCE ANALYSIS IN THE PHARMACEUTICAL-INDUSTRY [J].
MACDONALD, BF ;
PREBBLE, KA .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (11-12) :1077-1085
[8]  
PAULSON W, 1994, QUALITY CONTROL REPO, V28, P1
[9]   THE USE OF NEAR-INFRARED SPECTROSCOPY IN THE QUALITY-CONTROL LABORATORY OF THE PHARMACEUTICAL-INDUSTRY [J].
PLUGGE, W ;
VANDERVLIES, C .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1992, 10 (10-12) :797-803
[10]   NEAR-INFRARED SPECTROSCOPY AS AN ALTERNATIVE TO ASSESS COMPLIANCE OF AMPICILLIN-TRIHYDRATE WITH COMPENDIAL SPECIFICATIONS [J].
PLUGGE, W ;
VANDERVLIES, C .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1993, 11 (06) :435-442