Reliability of surface EMG matrix in locating the innervation zone of upper trapezius muscle

被引:26
作者
Barbero, Marco [1 ,2 ]
Gatti, Roberto [3 ]
Lo Conte, Loredana [4 ]
Macmillan, Fiona [2 ]
Coutts, Fiona [2 ]
Merletti, Roberto [4 ]
机构
[1] Univ Appl Sci So Switzerland, SUPSI, Dept Hlth Sci, Manno, Switzerland
[2] Queen Margaret Univ, Sch Hlth Sci, Edinburgh, Midlothian, Scotland
[3] Univ Vita Salute San Raffaele, Sch Physiotherapy, Milan, Italy
[4] Politecn Torino, Dept Elect, Lab Engn Neuromuscular Syst, I-10129 Turin, Italy
关键词
Electromyography; sEMG; Electrode arrays; Innervation zone; Trapezius; Inter-rater reliability; Intra-rater reliability; MEAN POWER FREQUENCY; ISOMETRIC TORQUE RELATIONSHIPS; VASTUS LATERALIS MUSCLE; EXTERNAL ANAL-SPHINCTER; ELECTROMYOGRAPHIC AMPLITUDE; ELECTRODE PLACEMENT; BICEPS; SHIFT; NORMALIZATION; MEDIALIS;
D O I
10.1016/j.jelekin.2011.05.013
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The identification of the motor unit (MU) innervation zone (IZ) using surface electromyographic (sEMG) signals detected on the skin with a linear array or a matrix of electrodes has been recently proposed in the literature. However, an analysis of the reliability of this procedure and, therefore, of the suitability of the sEMG signals for this purpose has not been reported. The purpose of this work is to describe the intra and inter-rater reliability and the suitability of surface EMG in locating the innervation zone of the upper trapezius muscle. Two operators were trained on electrode matrix positioning and sEMG signal analysis. Ten healthy subjects, instructed to perform a series of isometric contractions of the upper trapezius muscle participated in the study. The two operators collected sEMG signals and then independently estimated the IZ location through visual analysis. Results showed an almost perfect agreement for intra-rater and inter-rater reliability. The constancy of IZ location could be affected by the factors reflecting the population of active MUs and their IZs, including: the contraction intensity, the acquisition period analyzed, the contraction repetition. In almost all cases the IZ location shift due to these factors did not exceed 4 mm. Results generalization to other muscles should be made with caution. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:827 / 833
页数:7
相关论文
共 33 条
  • [31] Muscle fiber conduction velocity and EMG amplitude of the upper trapezius muscle in healthy subjects after low-level laser irradiation: a randomized, double-blind, placebo-controlled, crossover study
    Fabiana Sarilho de Mendonça
    Paulo de Tarso Camillo de Carvalho
    Daniela Aparecida Biasotto-Gonzalez
    Simone Aparecida Penimpedo Calamita
    Cid André Fidelis de Paula Gomes
    César Ferreira Amorim
    Marco Antônio Fumagalli
    Fabiano Politti
    Lasers in Medical Science, 2018, 33 : 737 - 744
  • [32] MICROCIRCULATION IN THE UPPER TRAPEZIUS MUSCLE DURING SUSTAINED SHOULDER LOAD IN HEALTHY WOMEN - AN ENDURANCE STUDY USING PERCUTANEOUS LASER-DOPPLER FLOWMETRY AND SURFACE ELECTROMYOGRAPHY
    LARSSON, SE
    CAI, HM
    ZHANG, QX
    LARSSON, R
    OBERG, PA
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1995, 70 (05) : 451 - 456
  • [33] MICROCIRCULATION IN THE UPPER TRAPEZIUS MUSCLE DURING VARYING LEVELS OF STATIC CONTRACTION, FATIGUE AND RECOVERY IN HEALTHY WOMEN - A STUDY USING PERCUTANEOUS LASER-DOPPLER FLOWMETRY AND SURFACE ELECTROMYOGRAPHY
    LARSSON, SE
    CAI, HM
    OBERG, PA
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1993, 66 (06) : 483 - 488