Effects of gravity on flow rate estimations of a centrifugal blood pump using the eccentric position of a levitated impeller

被引:6
作者
Shida, Shuya [1 ]
Masuzawa, Toru [1 ]
Osa, Masahiro [1 ]
机构
[1] Ibaraki Univ, Grad Sch Sci & Engn, Hitachi, Ibaraki, Japan
关键词
Flow rate estimation; ventricular assist device; magnetic suspension; gravity effects; centrifugal blood pump; DEVICE;
D O I
10.1177/0391398820917149
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Implantable ventricular assist devices are a type of mechanical circulatory support for assisting the pumping of the heart. Accurate estimation of the flow rate through such devices is critical to ensure effective performance. A novel method for estimating the flow rate using the passively stabilized position of a magnetically levitated impeller was developed by our group. However, the performance of the method is affected by the gravity vector, which depends on the patient's posture. In this study, the effects of gravity on the flow estimation method are analyzed, and a compensation method is proposed. The magnetically levitated impeller is axially suspended and radially restricted by passive stability in a centrifugal blood pump developed by our group. The gravity effects were evaluated by analyzing the relationships between the radial position of the magnetically levitated impeller and the flow rate with respect to the gravity direction. Accurate estimation of the flow rate could not be achieved when the direction of gravity with respect to impeller was unknown. A mean absolute error of up to 4.89 L/min was obtained for flow rate measurement range of 0-5 L/min. However, analysis of the equilibrium of forces on the passively stabilized impeller indicated that the effects of gravity on the flow estimation could be compensated by performing additional measurements of the gravity direction with respect to impeller. The method for compensating the effects of gravity on the flow estimation should improve the performance of therapy with the implantable ventricular assist devices.
引用
收藏
页码:774 / 781
页数:8
相关论文
共 21 条
[1]  
ANSYS, 2017, ANSYSCFX SOLV MOD GU
[2]   Alternation of left ventricular load by a continuous-flow left ventricular assist device with a native heart load control system in a chronic heart failure model [J].
Arakawa, Mamoru ;
Nishimura, Takashi ;
Takewa, Yoshiaki ;
Umeki, Akihide ;
Ando, Masahiko ;
Adachi, Hideo ;
Tatsumi, Eisuke .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 148 (02) :698-704
[3]   Measurement for implantable rotary blood pumps [J].
Bertram, CD .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (04) :R99-R117
[4]   Control of the Fluid Viscosity in a Mock Circulation [J].
Boes, Stefan ;
Ochsner, Gregor ;
Amacher, Raffael ;
Petrou, Anastasios ;
Meboldt, Mirko ;
Daners, Marianne Schmid .
ARTIFICIAL ORGANS, 2018, 42 (01) :68-77
[5]  
Brennen CE., 1994, HYDRODYNAMICS PUMPS
[6]   EXPERIMENTAL MEASUREMENTS OF HYDRODYNAMIC RADIAL FORCES AND STIFFNESS MATRICES FOR A CENTRIFUGAL PUMP-IMPELLER [J].
CHAMIEH, DS ;
ACOSTA, AJ ;
BRENNEN, CE ;
CAUGHEY, TK .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1985, 107 (03) :307-315
[7]   Investigation of the Influence of Volute Design on Journal Bearing Bias Force Using Computational Fluid Dynamics [J].
Graefe, Roland ;
Timms, Daniel ;
Boehning, Fiete ;
Schmitz-Rode, Thomas ;
Steinseifer, Ulrich .
ARTIFICIAL ORGANS, 2010, 34 (09) :760-765
[8]   Development of a Pump Flow Estimator for Rotary Blood Pumps to Enhance Monitoring of Ventricular Function [J].
Granegger, Marcus ;
Moscato, Francesco ;
Casas, Fernando ;
Wieselthaler, Georg ;
Schima, Heinrich .
ARTIFICIAL ORGANS, 2012, 36 (08) :691-699
[9]   Sensorless Viscosity Measurement in a Magnetically-Levitated Rotary Blood Pump [J].
Hijikata, Wataru ;
Rao, Jun ;
Abe, Shodai ;
Takatani, Setsuo ;
Shinshi, Tadahiko .
ARTIFICIAL ORGANS, 2015, 39 (07) :559-568
[10]   Detection of left ventricle function from a magnetically levitated impeller behavior [J].
Hoshi, H ;
Asama, J ;
Hara, C ;
Hijikata, W ;
Shinshi, T ;
Shimokohbe, A ;
Takatani, S .
ARTIFICIAL ORGANS, 2006, 30 (05) :377-383