Micro-needle implantable electrochemical oxygen sensor: ex-vivo and in-vivo studies

被引:45
|
作者
Rivas, Lourdes [2 ]
Dulay, Samuel [2 ]
Miserere, Sandrine [2 ]
Pla, Laura [4 ,5 ]
Marin, Sergio Berdun [4 ,5 ]
Parra, Johanna [4 ,5 ]
Eixarch, Elisenda [4 ,5 ,6 ]
Gratacos, Eduard [4 ,5 ,6 ]
Illa, Miriam [4 ,5 ]
Mir, Monica [1 ,2 ,3 ]
Samitier, Josep [1 ,2 ,3 ]
机构
[1] CIBER BBN, Monforte de Lemos 3-5,Pabellon 11, Madrid 28029, Spain
[2] BIST, Nanobioengn Grp, Inst Bioengn Catalonia IBEC, 12 Baldiri Reixac 15-21, Barcelona 08028, Spain
[3] Univ Barcelona, Dept Elect & Biomed Engn, Marti I Franques 1, Barcelona 08028, Spain
[4] Univ Barcelona, Fetal Med Res Ctr, BCNatal, Hosp Clin, Bldg Helios 2,Sabino Arana St 1, E-08028 Barcelona, Spain
[5] Univ Barcelona, Hosp St Joan Deu, Bldg Helios 2,Sabino Arana St 1, E-08028 Barcelona, Spain
[6] IDIBAPS, Barcelona, Spain
来源
基金
欧盟地平线“2020”;
关键词
Oxygen sensor; Implantable sensor; In-vivo test; Hypoxia; Ischemin; Naflon; REDUCTION; RABBIT;
D O I
10.1016/j.bios.2020.112028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Oxygen is vital for energy metabolism in mammals and the variability of the concentration is considered a clinical alert for a wide range of metabolic malfunctions in medicine. In this article, we describe the development and application of a micro-needle implantable platinum-based electrochemical sensor for measuring partial pressure of oxygen in intramuscular tissue (in-vivo) and vascular blood (ex-vivo). The Pt-Nafion (R) sensor was characterized morphological and electrochemically showing a higher sensitivity of -2.496 nA/mmHg (-1.495 nA/mu M) when comparing with its bare counterpart. Our sensor was able to discriminate states with different oxygen partial pressures (pO(2)) for ex-vivo (blood) following the same trend of the commercial gas analyzer used as standard. For in-vivo (intramuscular) experiments, since there is not a gold standard for measuring pO(2) in tissue, it was not possible to correlate the obtained currents with the pO(2) in tissue. However, our sensor was able to detect clear statistical differences of O-2 between hyperoxia and hypoxia states in tissue.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Fetoscopic Panorama Reconstruction: Moving from Ex-vivo to In-vivo
    Gaisser, Floris
    Peeters, Suzanne H. P.
    Lenseigne, Boris
    Jonker, Pieter P.
    Oepkes, Dick
    MEDICAL IMAGE UNDERSTANDING AND ANALYSIS (MIUA 2017), 2017, 723 : 581 - 593
  • [12] INFRARED SPECTROSCOPIC INVESTIGATION OF IN-VIVO AND EX-VIVO HUMAN NAILS
    SOWA, MG
    WANG, J
    SCHULTZ, CP
    AHMED, MK
    MANTSCH, HH
    VIBRATIONAL SPECTROSCOPY, 1995, 10 (01) : 49 - 56
  • [13] Comparison of in-vivo and ex-vivo Dielectric Properties of Biological Tissues
    Salahuddin, Saqib
    La Gioia, Alessandra
    Elahi, Muhammad Adnan
    Porter, Emily
    O'Halloran, Martin
    Shahzad, Atif
    2017 INTERNATIONAL CONFERENCE ON ELECTROMAGNETICS IN ADVANCED APPLICATIONS (ICEAA), 2017, : 582 - 585
  • [14] TRACHEO-BRONCHIAL COLLAPSIBILITY AN IN-VIVO AND EX-VIVO STUDY
    BRYANT, LR
    HOUCK, GR
    LOUGHRIN, JR
    LIEBER
    RESPIRATION, 1970, 27 (01) : 74 - &
  • [15] In-vivo and Ex-vivo HRV Discrimination by Complex Correlation Measure
    Janousek, Oto
    Francisco, Sara
    Ronzhina, Marina
    Vesely, Petr
    Kolarova, Jana
    Provaznik, Ivo
    Novakova, Marie
    Scheer, Peter
    2013 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2013, 40 : 441 - 444
  • [16] Registration of in-vivo to ex-vivo MRI of surgically resected specimens: A pipeline for histology to in-vivo registration
    Goubran, Maged
    de Ribaupierre, Sandrine
    Hammond, Robert R.
    Currie, Catherine
    Burneo, Jorge G.
    Parrent, Andrew G.
    Peters, Terry M.
    Khan, Ali R.
    JOURNAL OF NEUROSCIENCE METHODS, 2015, 241 : 53 - 65
  • [17] In-Vivo and Ex-Vivo Brain Uptake Studies of Peptidomimetic Neurolysin Activators in Healthy and Stroke Animals
    Saeideh Nozohouri
    Shiva Hadi Esfahani
    Behnam Noorani
    Dhaval Patel
    Heidi Villalba
    Yashwardhan Ghanwatkar
    Md. Shafikur Rahman
    Yong Zhang
    Ulrich Bickel
    Paul C. Trippier
    Vardan T. Karamyan
    Thomas J. Abbruscato
    Pharmaceutical Research, 2022, 39 : 1587 - 1598
  • [18] Needle-in-needle electrochemical sensor for in-vivo monitoring of anticancer drug etoposide
    Liu, Weilu
    Li, Qiuyun
    Han, Qiushuo
    BIOSENSORS & BIOELECTRONICS, 2024, 258
  • [19] In-Vivo and Ex-Vivo Brain Uptake Studies of Peptidomimetic Neurolysin Activators in Healthy and Stroke Animals
    Nozohouri, Saeideh
    Esfahani, Shiva Hadi
    Noorani, Behnam
    Patel, Dhaval
    Villalba, Heidi
    Ghanwatkar, Yashwardhan
    Rahman, Md Shafikur
    Zhang, Yong
    Bickel, Ulrich
    Trippier, Paul C.
    Karamyan, Vardan T.
    Abbruscato, Thomas J.
    PHARMACEUTICAL RESEARCH, 2022, 39 (07) : 1587 - 1598
  • [20] Heterogeneous Breast Phantoms based in Real in-vivo and ex-vivo measurements
    Minano-Saravia, Ivana
    Fernandez-Aranzamendi, E.
    Condori-Huayna, Manuel
    Castillo-Aranibar, P.
    San-Roman, E.
    Gonzalez-Posadas, Vicente
    Segovia-Vargas, Daniel
    2023 17TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION, EUCAP, 2023,