Micro-needle implantable electrochemical oxygen sensor: ex-vivo and in-vivo studies

被引:45
|
作者
Rivas, Lourdes [2 ]
Dulay, Samuel [2 ]
Miserere, Sandrine [2 ]
Pla, Laura [4 ,5 ]
Marin, Sergio Berdun [4 ,5 ]
Parra, Johanna [4 ,5 ]
Eixarch, Elisenda [4 ,5 ,6 ]
Gratacos, Eduard [4 ,5 ,6 ]
Illa, Miriam [4 ,5 ]
Mir, Monica [1 ,2 ,3 ]
Samitier, Josep [1 ,2 ,3 ]
机构
[1] CIBER BBN, Monforte de Lemos 3-5,Pabellon 11, Madrid 28029, Spain
[2] BIST, Nanobioengn Grp, Inst Bioengn Catalonia IBEC, 12 Baldiri Reixac 15-21, Barcelona 08028, Spain
[3] Univ Barcelona, Dept Elect & Biomed Engn, Marti I Franques 1, Barcelona 08028, Spain
[4] Univ Barcelona, Fetal Med Res Ctr, BCNatal, Hosp Clin, Bldg Helios 2,Sabino Arana St 1, E-08028 Barcelona, Spain
[5] Univ Barcelona, Hosp St Joan Deu, Bldg Helios 2,Sabino Arana St 1, E-08028 Barcelona, Spain
[6] IDIBAPS, Barcelona, Spain
来源
基金
欧盟地平线“2020”;
关键词
Oxygen sensor; Implantable sensor; In-vivo test; Hypoxia; Ischemin; Naflon; REDUCTION; RABBIT;
D O I
10.1016/j.bios.2020.112028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Oxygen is vital for energy metabolism in mammals and the variability of the concentration is considered a clinical alert for a wide range of metabolic malfunctions in medicine. In this article, we describe the development and application of a micro-needle implantable platinum-based electrochemical sensor for measuring partial pressure of oxygen in intramuscular tissue (in-vivo) and vascular blood (ex-vivo). The Pt-Nafion (R) sensor was characterized morphological and electrochemically showing a higher sensitivity of -2.496 nA/mmHg (-1.495 nA/mu M) when comparing with its bare counterpart. Our sensor was able to discriminate states with different oxygen partial pressures (pO(2)) for ex-vivo (blood) following the same trend of the commercial gas analyzer used as standard. For in-vivo (intramuscular) experiments, since there is not a gold standard for measuring pO(2) in tissue, it was not possible to correlate the obtained currents with the pO(2) in tissue. However, our sensor was able to detect clear statistical differences of O-2 between hyperoxia and hypoxia states in tissue.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Implantable Fiber Bragg Grating Sensor for Continuous Heart Activity Monitoring: Ex-Vivo and In-Vivo Validation
    Ferraro, Davide
    D'Alesio, Giacomo
    Camboni, Domenico
    Zinno, Ciro
    Costi, Leone
    Haberbusch, Max
    Aigner, Philipp
    Maw, Martin
    Schloglhofer, Thomas
    Unger, Ewald
    Aliperta, Andrea
    Bernini, Fabio
    Casieri, Valentina
    Terlizzi, Domiziana
    Giudetti, Guido
    Carpaneto, Jacopo
    Pedrizzetti, Gianni
    Micera, Silvestro
    Lionetti, Vincenzo
    Moscato, Francesco
    Massari, Luca
    Oddo, Calogero Maria
    IEEE SENSORS JOURNAL, 2021, 21 (13) : 14051 - 14059
  • [2] A Minimally Invasive Flexible Micro-Needle Array as Continuous in vivo Electrochemical Glucose Sensor
    Mou, Qun
    Li, Junshi
    Zheng, Fengyi
    Cui, Yue
    Jin, Yufeng
    Li, Zhihong
    2019 13TH IEEE INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE & ENGINEERING (IEEE-NANOMED 2019), 2019, : 258 - 261
  • [3] A Minimally Invasive Flexible Micro-Needle Array as Continuous in vivo Electrochemical Glucose Sensor
    Mou, Qun
    Li, Junshi
    Zheng, Fengyi
    Cui, Yue
    Jin, Yufeng
    Li, Zhihong
    2019 13TH IEEE INTERNATIONAL CONFERENCE ON NANO/MOLECULAR MEDICINE & ENGINEERING (IEEE-NANOMED 2019), 2019, : 98 - 98
  • [4] COMPARISON OF FUNCTION OF EX-VIVO AND IN-VIVO LIVERS
    CUSCHIERI, A
    BAKER, PR
    SHIELDS, R
    BRITISH JOURNAL OF SURGERY, 1972, 59 (11) : 901 - +
  • [5] Ex-vivo systems for neuromodulation: A comparison of ex-vivo and in-vivo large animal nerve electrophysiology
    Ribeiro, Mafalda
    Andreis, Felipe R.
    Jabban, Leen
    Nielsen, Thomas G. N. dS.
    Smirnov, Sergey, V
    Lutteroth, Christof
    Proulx, Michael J.
    Rocha, Paulo R. F.
    Metcalfe, Benjamin
    JOURNAL OF NEUROSCIENCE METHODS, 2024, 406
  • [6] THE SEROTONERGIC ANTIDEPRESSANT NEFAZODONE INHIBITS THE SEROTONIN TRANSPORTER - IN-VIVO AND EX-VIVO STUDIES
    OWENS, MJ
    IENI, JR
    KNIGHT, DL
    WINDERS, K
    NEMEROFF, CB
    LIFE SCIENCES, 1995, 57 (24) : PL373 - PL380
  • [7] ASSESSMENT OF HEPATOBILIARY FUNCTION IN-VIVO AND EX-VIVO IN THE RAT
    HANDLER, JA
    KOSSOR, DC
    GOLDSTEIN, RS
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 1994, 31 (01) : 11 - 19
  • [8] Atypical fibroxanthoma: in-vivo and ex-vivo confocal features
    Pampena, Riccardo
    Peccerillo, Francesca
    Piana, Simonetta
    Paolino, Giovanni
    Mercuri, Santo R.
    Pellacani, Giovanni
    Longo, Caterina
    ITALIAN JOURNAL OF DERMATOLOGY AND VENEREOLOGY, 2021, 156 (06) : 41 - 42
  • [9] STUDIES ON THE THROMBOGENIC EFFECTS OF RECOMBINANT TISSUE FACTOR - IN-VIVO VERSUS EX-VIVO FINDINGS
    CALLAS, DD
    BACHER, P
    FAREED, J
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 1995, 21 (02): : 166 - 176
  • [10] In-vitro, in-vivo and ex-vivo studies with oral β-lactams against Streptococcus pneumoniae
    Pérez-Trallero, E
    Alkorta, M
    García-Arenzana, JM
    Iturzaeta, A
    Gomariz, M
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1998, 41 (06) : 629 - 634