Uterine Tumors: Comparison of 3D versus 2D T2-weighted Turbo Spin-Echo MR Imaging at 3.0 T-Initial Experience

被引:53
作者
Hori, Masatoshi [1 ]
Kim, Tonsok [1 ]
Onishi, Hiromitsu [1 ]
Ueguchi, Takashi [2 ]
Tatsumi, Mitsuaki [2 ]
Nakamoto, Atsushi [1 ]
Tsuboyama, Takahiro [1 ]
Tomoda, Kaname [2 ]
Tomiyama, Noriyuki [1 ]
机构
[1] Osaka Univ, Dept Radiol, Grad Sch Med, Suita, Osaka 5650871, Japan
[2] Osaka Univ Hosp, Dept Radiol, Osaka 553, Japan
关键词
CERVICAL-CARCINOMA; ENDOMETRIAL CANCER; SINGLE-SLAB; QUALITY; DIAGNOSIS;
D O I
10.1148/radiol.10100866
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare a three-dimensional (3D) T2-weighted turbo spin-echo (TSE) magnetic resonance (MR) sequence (VISTA; Philips Medical Systems, Best, the Netherlands) with a two-dimensional (2D) T2-weighted TSE sequence in terms of image quality, signal intensity (SI) difference ratios, conspicuity, and staging of uterine tumors. Materials and Methods: This retrospective study was approved by the institutional review board, and informed consent was waived. Sixty-one women (mean age, 53.0 years +/- 13.7 [standard deviation]; range, 30-87 years) with cervical carcinoma (n = 28), endometrial carcinoma (n = 21), or leiomyoma (n = 30) of the uterus were included. Patients underwent T2-weighted MR imaging at 3 T with both 1-mm-thick 3D and 5-mm-thick 2D T2-weighted TSE sequences. Three-dimensional T2-weighted TSE images were reconstructed at 5-mm thickness with the aid of a workstation. Quantitative analyses of signal-to-noise ratio (SNR) and SI difference ratios between tumors and other tissues and qualitative analyses of image quality and tissue conspicuity were performed. Two radiologists independently assessed local-regional staging for carcinomas. Quantitative values, qualitative scores, and tumor staging were analyzed by using the paired t test, Wilcoxon signed rank test, and McNemar test, respectively. Results: Mean myometrial SNR was higher on 3D than 2D images (14.3 vs 9.8; P < .0001). Mean SI difference ratios between cervical (0.45 vs 0.34; P < .0001) or endometrial (0.46 vs 0.40; P = .044) carcinomas and gluteal muscle were higher on 3D images, but those between leiomyoma and myometrium (0.33 vs 0.43; P < .0001) were lower than those on 2D images. Image quality (P = .0004) and carcinoma conspicuity (P < .0005) were superior with the 3D T2-weighted TSE sequence. Although multiplanar reconstruction of 3D T2-weighted TSE images was useful for staging in one case, there were no significant differences between 3D and 2D T2-weighted TSE imaging in accuracy of staging for the two readers for cervical or endometrial carcinoma. Conclusion: The 3D T2-weighted TSE sequence showed certain advantages over the 2D T2-weighted TSE sequence, and it has the potential to improve the performance of MR imaging for the evaluation of uterine carcinoma. (C) RSNA, 2010
引用
收藏
页码:154 / 163
页数:10
相关论文
共 29 条
[1]   Evaluation of Uterine Anomalies: 3D FRFSE Cube Versus Standard 2D FRFSE [J].
Agrawal, Garima ;
Riherd, Jody M. ;
Busse, Reed F. ;
Hinshaw, J. Louis ;
Sadowski, Elizabeth A. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 193 (06) :W558-W562
[2]  
*AM CANC SOC, 2009, CANC FACTS FIG 2009, V4
[3]  
[Anonymous], NCCN CLIN PRACT GUID
[4]   Computed tomography and magnetic resonance imaging in staging of uterine cervical carcinoma: a systematic review [J].
Bipat, S ;
Glas, AS ;
van der Velden, J ;
Zwinderman, AH ;
Bossuyt, PMM ;
Stoker, J .
GYNECOLOGIC ONCOLOGY, 2003, 91 (01) :59-66
[5]   Pelvic imaging using a T1W fat-suppressed three-dimensional dual echo dixon technique at 3T [J].
Cornfeld, Daniel M. ;
Israel, Gary ;
McCarthy, Shirley M. ;
Weinreb, Jeffery C. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (01) :121-127
[6]  
CREASMAN WT, 1987, CANCER, V60, P2035, DOI 10.1002/1097-0142(19901015)60:8+<2035::AID-CNCR2820601515>3.0.CO
[7]  
2-8
[8]  
Evans P, 2007, AM FAM PHYSICIAN, V75, P1503
[9]   CLINICAL STAGE-I ENDOMETRIAL CANCER - PROGNOSTIC FACTORS FOR LOCAL-CONTROL AND DISTANT METASTASIS AND IMPLICATIONS OF THE NEW FIGO SURGICAL STAGING SYSTEM [J].
GRIGSBY, PW ;
PEREZ, CA ;
KUTEN, A ;
SIMPSON, JR ;
GARCIA, DM ;
CAMEL, HM ;
KAO, MS ;
GALAKATOS, AE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 22 (05) :905-911
[10]   Noise measurement and estimation in MR imaging experiments [J].
Heverhagen, Johannes T. .
RADIOLOGY, 2007, 245 (03) :638-639