Versatile 3-channel high-voltage power supply for microchip capillary electrophoresis

被引:56
作者
García, CD [1 ]
Liu, Y [1 ]
Anderson, P [1 ]
Henry, CS [1 ]
机构
[1] Colorado State Univ, Dept Chem, Ft Collins, CO 80523 USA
关键词
D O I
10.1039/b309339e
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The fabrication of a battery operated 3-channel high voltage power supply for microchip capillary electrophoresis is described. The power supply consists of two positive and one negative DC-DC converters, a microprocessor controlled timer, a battery and a transformer to recharge the battery and feed the high voltage relays. This arrangement allows the possibility to control the potentials applied in the 0 to +/-4000 V range to a variety of microchip setups. It can also be easily adapted to perform either gated or pinched injection. The inclusion of a rechargeable battery was adopted to feed the DC-DC converters to reduce noise levels and achieve portability.
引用
收藏
页码:324 / 328
页数:5
相关论文
共 18 条
[1]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[2]   Finite element simulation of pinched pressure-driven flow injection in microchannels [J].
Bai, XX ;
Josserand, J ;
Jensen, H ;
Rossier, JS ;
Girault, HH .
ANALYTICAL CHEMISTRY, 2002, 74 (24) :6205-6215
[3]   Direct determination of carbohydrates, amino acids, and antibiotics by microchip electrophoresis with pulsed amperometric detection [J].
García, CD ;
Henry, CS .
ANALYTICAL CHEMISTRY, 2003, 75 (18) :4778-4783
[4]   Sample manipulation in micro total analytical systems [J].
Greenwood, PA ;
Greenway, GM .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (11) :726-740
[5]   Portable high-voltage power supply and electrochemical detection circuits for microchip capillary electrophoresis [J].
Jackson, DJ ;
Naber, JF ;
Roussel, TJ ;
Crain, MM ;
Walsh, KM ;
Keynton, RS ;
Baldwin, RP .
ANALYTICAL CHEMISTRY, 2003, 75 (14) :3643-3649
[6]   Portable capillary electrophoresis instrument with potentiometric detection [J].
Kappes, T ;
Hauser, PC .
ANALYTICAL COMMUNICATIONS, 1998, 35 (10) :325-329
[7]   Portable capillary electrophoresis instrument with amperometric, potentiometric and conductometric detection [J].
Kappes, T ;
Galliker, B ;
Schwarz, MA ;
Hauser, PC .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (03) :133-139
[8]  
LI FY, 2001, P SOC PHOTO-OPT INS, V4199, P51
[9]   In-channel electrochemical detection for microchip capillary electrophoresis using an electrically isolated potentiostat [J].
Martin, RS ;
Ratzlaff, KL ;
Huynh, BH ;
Lunte, SM .
ANALYTICAL CHEMISTRY, 2002, 74 (05) :1136-+
[10]  
Ng JMK, 2002, ELECTROPHORESIS, V23, P3461, DOI 10.1002/1522-2683(200210)23:20<3461::AID-ELPS3461>3.0.CO