Artificial Intelligence for the Measurement of the Aortic Valve Annulus

被引:26
|
作者
Thalappillil, Richard [1 ]
Datta, Pranav [1 ]
Datta, Saurabh [1 ]
Zhan, Yong [2 ]
Wells, Sophie [3 ]
Mahmood, Feroze [4 ]
Cobey, Frederick C. [1 ]
机构
[1] Tufts Med Ctr, Dept Anesthesiol & Perioperat Med, Div Cardiac Anesthesiol, Boston, MA 02111 USA
[2] Tufts Med Ctr, Dept Surg, Div Cardiac Surg, Boston, MA 02111 USA
[3] Tufts Med Ctr, Dept Med, Div Cardiol, Boston, MA 02111 USA
[4] Beth Israel Deaconess Med Ctr, Div Cardiac Anesthesiol, Boston, MA 02215 USA
关键词
artificial intelligence; automated software; machine learning; aortic valve three-dimensional modeling; CT;
D O I
10.1053/j.jvca.2019.06.017
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: The authors aim to evaluate an automated echocardiography software as compared with computed tomography in measurement of the aortic valve annulus in patients with aortic stenosis. The authors hypothesize that aortic annular measurements by this software and computed tomography will show acceptable correlation. Design: This study is an Institutional Review Board-approved, retrospective data collection of patients with aortic stenosis who underwent implantation of a transcatheter heart valve with intraprocedural transesophageal echocardiography, multidetector computed tomography, and use of the Siemens eSie Valves automated aortic valve software. Setting: Intraprocedural in a single hospital institution. Participants: The participants are 47 patients who underwent implantation of an Edwards SAPIEN 3 transcatheter heart valve. Interventions: The authors compared aortic valve annulus measurements by two-dimensional transesophageal echocardiography, computed tomography, and the automated software. Measurements and Main Results: Aortic annulus measurements by the software correlated more closely to the computed tomography measurements than two-dimensional measurements. Bland-Altman analysis showed qualitative comparability of measurements performed by the automated software to computed tomography (95% limits of agreement between -4.62 mm and 1.26 mm for area-derived and -4.51 mm and 1.45 mm for perimeter-derived methods). Similarly, there was significant linear correlation with automated software use (r = 0.84, p < 0.0001 and r = 0.85, p<0.0001). Conclusions: Periprocedural aortic valve measurement by automated echocardiographic software correlates with computed tomography in patients with severe aortic stenosis. This technology is helpful and accurate, but has limitations. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:65 / 71
页数:7
相关论文
共 50 条
  • [41] Application of Artificial Intelligence in Lung Cancer
    Chiu, Hwa-Yen
    Chao, Heng-Sheng
    Chen, Yuh-Min
    CANCERS, 2022, 14 (06)
  • [42] Lung Imaging and Artificial Intelligence in ARDS
    Chiumello, Davide
    Coppola, Silvia
    Catozzi, Giulia
    Danzo, Fiammetta
    Santus, Pierachille
    Radovanovic, Dejan
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (02)
  • [43] Application of Logistic Regression and Artificial Intelligence in the Risk Prediction of Acute Aortic Dissection Rupture
    Lin, Yanya
    Hu, Jianxiong
    Xu, Rongbin
    Wu, Shaocong
    Ma, Fei
    Liu, Hui
    Xie, Ying
    Li, Xin
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (01)
  • [44] Artificial Intelligence Pathologist: The use of Artificial Intelligence in Digital Healthcare
    Kaddour, Asmaa Ben Ali
    Abdulaziz, Nidhal
    2021 IEEE GLOBAL CONFERENCE ON ARTIFICIAL INTELLIGENCE AND INTERNET OF THINGS (GCAIOT), 2021, : 31 - 36
  • [45] Artificial Intelligence-Assisted Sac Diameter Assessment for Complex Endovascular Aortic Repair
    Wegner, Moritz
    Fontaine, Vincent
    Nana, Petroula
    Dieffenbach, Bryan V.
    Fabre, Dominique
    Haulon, Stephan
    JOURNAL OF ENDOVASCULAR THERAPY, 2023,
  • [46] Artificial Intelligence Improves Prediction of Major Adverse Cardiovascular Events in Patients Undergoing Transcatheter Aortic Valve Replacement Planning CT
    Tremamunno, Giuseppe
    Vecsey-Nagy, Milan
    Schoepf, U. Joseph
    Zsarnoczay, Emese
    Aquino, Gilberto J.
    Kravchenko, Dmitrij
    Laghi, Andrea
    Jacob, Athira
    Sharma, Puneet
    Rapaka, Saikiran
    O'Doherty, Jim
    Suranyi, Pal Spruill
    Kabakus, Ismail Mikdat
    Amoroso, Nicholas S.
    Steinberg, Daniel H.
    Emrich, Tilman
    Varga-Szemes, Akos
    ACADEMIC RADIOLOGY, 2025, 32 (02) : 702 - 711
  • [47] The Use of Artificial Intelligence and Wearable Inertial Measurement Units in Medicine: Systematic Review
    Serena, Ricardo Smits
    Hinterwimmer, Florian
    Burgkart, Rainer
    von Eisenhart-Rothe, Rudiger
    Rueckert, Daniel
    JMIR MHEALTH AND UHEALTH, 2025, 13
  • [48] Will Artificial Intelligence Deliver Precision Medicine for Patients With Aortic Stenosis?
    Bruining, Nico
    Jaegere, Peter P. T. de
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (19) : 2141 - 2143
  • [49] Artificial intelligence-analyzed computed tomography in patients undergoing transcatheter tricuspid valve repair
    Kirchner, Johannes
    Gercek, Muhammed
    Gesch, Johannes
    Omran, Hazem
    Friedrichs, Kai
    Rudolph, Felix
    Ivannikova, Maria
    Rossnagel, Tobias
    Piran, Misagh
    Pfister, Roman
    Blanke, Philipp
    Rudolph, Volker
    Rudolph, Tanja K.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2024, 411
  • [50] Recursive multiresolution convolutional neural networks for 3D aortic valve annulus planimetry
    Pascal Theriault-Lauzier
    Hind Alsosaimi
    Negareh Mousavi
    Jean Buithieu
    Marco Spaziano
    Giuseppe Martucci
    James Brophy
    Nicolo Piazza
    International Journal of Computer Assisted Radiology and Surgery, 2020, 15 : 577 - 588