Artificial Intelligence for the Measurement of the Aortic Valve Annulus

被引:26
|
作者
Thalappillil, Richard [1 ]
Datta, Pranav [1 ]
Datta, Saurabh [1 ]
Zhan, Yong [2 ]
Wells, Sophie [3 ]
Mahmood, Feroze [4 ]
Cobey, Frederick C. [1 ]
机构
[1] Tufts Med Ctr, Dept Anesthesiol & Perioperat Med, Div Cardiac Anesthesiol, Boston, MA 02111 USA
[2] Tufts Med Ctr, Dept Surg, Div Cardiac Surg, Boston, MA 02111 USA
[3] Tufts Med Ctr, Dept Med, Div Cardiol, Boston, MA 02111 USA
[4] Beth Israel Deaconess Med Ctr, Div Cardiac Anesthesiol, Boston, MA 02215 USA
关键词
artificial intelligence; automated software; machine learning; aortic valve three-dimensional modeling; CT;
D O I
10.1053/j.jvca.2019.06.017
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: The authors aim to evaluate an automated echocardiography software as compared with computed tomography in measurement of the aortic valve annulus in patients with aortic stenosis. The authors hypothesize that aortic annular measurements by this software and computed tomography will show acceptable correlation. Design: This study is an Institutional Review Board-approved, retrospective data collection of patients with aortic stenosis who underwent implantation of a transcatheter heart valve with intraprocedural transesophageal echocardiography, multidetector computed tomography, and use of the Siemens eSie Valves automated aortic valve software. Setting: Intraprocedural in a single hospital institution. Participants: The participants are 47 patients who underwent implantation of an Edwards SAPIEN 3 transcatheter heart valve. Interventions: The authors compared aortic valve annulus measurements by two-dimensional transesophageal echocardiography, computed tomography, and the automated software. Measurements and Main Results: Aortic annulus measurements by the software correlated more closely to the computed tomography measurements than two-dimensional measurements. Bland-Altman analysis showed qualitative comparability of measurements performed by the automated software to computed tomography (95% limits of agreement between -4.62 mm and 1.26 mm for area-derived and -4.51 mm and 1.45 mm for perimeter-derived methods). Similarly, there was significant linear correlation with automated software use (r = 0.84, p < 0.0001 and r = 0.85, p<0.0001). Conclusions: Periprocedural aortic valve measurement by automated echocardiographic software correlates with computed tomography in patients with severe aortic stenosis. This technology is helpful and accurate, but has limitations. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:65 / 71
页数:7
相关论文
共 50 条
  • [21] Harnessing the power of artificial intelligence in predicting all-cause mortality in transcatheter aortic valve replacement: a systematic review and meta-analysis
    Sazzad, Faizus
    Ler, Ashlynn Ai Li
    Furqan, Mohammad Shaheryar
    Tan, Linus Kai Zhe
    Leo, Hwa Liang
    Kuntjoro, Ivandito
    Tay, Edgar
    Kofidis, Theo
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [22] Efficient screening for severe aortic valve stenosis using understandable artificial intelligence: a prospective diagnostic accuracy study
    Makimoto, Hisaki
    Shiraga, Takeru
    Kohlmann, Benita
    Magnisali, Christofori Eleni
    Gerguri, Shqipe
    Motoyama, Nobuaki
    Clasen, Lukas
    Bejinariu, Alexandru
    Klein, Kathrin
    Makimoto, Asuka
    Jung, Christian
    Westenfeld, Ralf
    Zeus, Tobias
    Kelm, Malte
    EUROPEAN HEART JOURNAL - DIGITAL HEALTH, 2022, 3 (02): : 141 - 152
  • [23] Artificial Intelligence for Automatic Measurement of Left Ventricular Strain in Echocardiography
    Salte, Ivar M.
    ostvik, Andreas
    Smistad, Erik
    Melichova, Daniela
    Nguyen, Thuy Mi
    Karlsen, Sigve
    Brunvand, Harald
    Haugaa, Kristina H.
    Edvardsen, Thor
    Lovstakken, Lasse
    Grenne, Bjornar
    JACC-CARDIOVASCULAR IMAGING, 2021, 14 (10) : 1918 - 1928
  • [24] Artificial Intelligence in Nuclear Cardiology
    Miller, Robert J. H.
    CARDIOLOGY CLINICS, 2023, 41 (02) : 151 - 161
  • [25] Artificial Intelligence in Nuclear Medicine
    Nensa, Felix
    Demircioglu, Aydin
    Rischpler, Christoph
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60 : 29S - 37S
  • [26] Artificial Intelligence Applied to the Electrocardiogram Predicts Outcomes in Patients With Severe Aortic Stenosis and Potential Cardiac Amyloidosis Undergoing Transcatheter Aortic Valve Replacement
    Pereyra, Milagros
    Farina, Juan
    Mahmoud, Ahmed K.
    Scalia, Isabel G.
    Galasso, Francesca
    Killian, Michael E.
    Suppah, Mustafa
    Chao, Chieh-Ju
    Sweeney, John P.
    Fortuin, Floyd D.
    Rosenthal, Julie
    CIRCULATION, 2023, 148
  • [27] Artificial Intelligence Applications in Stroke
    Mouridsen, Kim
    Thurner, Patrick
    Zaharchuk, Greg
    STROKE, 2020, 51 (08) : 2573 - 2579
  • [28] Automatic Measurement of Maximal Diameter of Abdominal Aortic Aneurysm on Computed Tomography Angiography Using Artificial Intelligence
    Lareyre, Fabien
    Chaudhuri, Arindam
    Flory, Violaine
    Augene, Emmanuel
    Adam, Cedric
    Carrier, Marion
    Amrani, Samantha
    Chikande, Julien
    Cong Duy Le
    Raffort, Juliette
    ANNALS OF VASCULAR SURGERY, 2022, 83 : 202 - 211
  • [29] Preoperative Assessment of Aortic Annulus Dimensions: Comparison of Noninvasive and Intraoperative Measurement
    Dashkevich, Alexey
    Blanke, Philipp
    Siepe, Matthias
    Pache, Gregor
    Langer, Mathias
    Schlensak, Christian
    Beyersdorf, Friedhelm
    ANNALS OF THORACIC SURGERY, 2011, 91 (03) : 709 - 715
  • [30] Aortic Annulus Detection Based on Deep Learning for Transcatheter Aortic Valve Replacement Using Cardiac Computed Tomography
    Cho, Yongwon
    Park, Soojung
    Hwang, Sung Ho
    Ko, Minseok
    Lim, Do-Sun
    Yu, Cheol Woong
    Park, Seong-Mi
    Kim, Mi-Na
    Oh, Yu-Whan
    Yang, Guang
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2023, 38 (37)