Inhibition of neointimal proliferation after bare metal stent implantation with low-pressure drug delivery using a paclitaxel-coated balloon in porcine coronary arteries

被引:17
作者
Cremers, Bodo [1 ]
Kelsch, Bettina [2 ]
Clever, Yvonne P. [1 ]
Hattangadi, Neil
Mahnkopf, Dirk [3 ]
Speck, Ulrich [2 ]
Taupitz, Matthias [2 ]
Scheller, Bruno [1 ]
机构
[1] Univ Saarland, Dept Internal Med 3, D-66421 Homburg, Germany
[2] Charite Humboldt Univ, Dept Radiol, Berlin, Germany
[3] IMTR GmbH, Inst Med Technol & Res, Rottmersleben, Germany
关键词
Restenosis; Drug-coated balloon catheter; Paclitaxel; Atherectomy; Angioplasty; ELUTING STENTS; CONTRAST-MEDIA; RESTENOSIS; PREVENTION; CATHETER; MODELS; RECOMMENDATIONS; ANGIOPLASTY; INJURY; TRIAL;
D O I
10.1007/s00392-011-0408-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A variety of mechanical and laser-based methods remove or shift atherosclerotic plaques and reopen the artery to its original lumen. Subsequent treatment with drug-coated balloons (DCB) may smooth the vessel wall but does not require high-pressure inflation. We investigated the efficacy of paclitaxel-coated balloons inflated with only 2 atm after bare metal stent implantation in coronary arteries of 24 pigs. Angiography and histomorphometry was performed on day 28. DCB inflated with 2 atm caused similar reduction of late lumen loss (LLL) as high-pressure inflation with 12 atm (0.89 +/- 0.58 vs. 0.72 +/- 0.39 mm, p = 0.34). Both DCB treatments significantly (p < 0.01) reduced LLL versus uncoated balloons (1.50 +/- 0.51 mm). Treatment with low-pressure DCB resulted in less maximal intimal thickness (0.45 +/- 0.15 vs. 0.67 +/- 0.25 mm) and neointimal area (2.93 +/- 0.73 vs. 3.82 +/- 1.27 mm(2)) than treatment with uncoated balloons (p < 0.05). In conclusion, low-pressure treatment with DCB was similarly effective as high-pressure treatment justifying clinical trials in vessels which will benefit from inhibition of neointimal proliferation but may not tolerate high inflation pressure.
引用
收藏
页码:385 / 391
页数:7
相关论文
共 21 条
[1]   Current status of rotational atherectomy [J].
Cavusoglu, E ;
Kini, AS ;
Marmur, JD ;
Sharma, SK .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 62 (04) :485-498
[2]   Drug-Coated Balloons for the Prevention of Vascular Restenosis [J].
Gray, William A. ;
Granada, Juan F. .
CIRCULATION, 2010, 121 (24) :2672-2680
[3]   Catheter-Based Delivery of Fluid Paclitaxel for Prevention of Restenosis in Native Coronary Artery Lesions After Stent Implantation [J].
Herdeg, Christian ;
Goehring-Frischholz, Katrin ;
Haase, Karl K. ;
Geisler, Tobias ;
Zuern, Christine ;
Hartmann, Ulrike ;
Woehrle, Jochen ;
Nusser, Thorsten ;
Dippon, Juergen ;
May, Andreas E. ;
Gawaz, Meinrad .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (04) :294-U42
[4]  
Johnson GJ, 1999, THROMB HAEMOSTASIS, V81, P835
[5]   Sirolimus-eluting stents vs paclitaxel-eluting stents in patients with coronary artery disease -: Meta-analysis of randomized trials [J].
Kastrati, A ;
Dibra, A ;
Eberle, S ;
Mehilli, J ;
de Lezo, JS ;
Goy, JJ ;
Ulm, K ;
Schömig, A .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 294 (07) :819-825
[6]   Sirolimus-eluting stent or paclitaxel-eluting stent vs balloon angioplasty for prevention of recurrences in patients with coronary in-stent restenosis -: A randomized controlled trial [J].
Kastrati, A ;
Mehilli, J ;
von Beckerath, N ;
Dibra, A ;
Hausleiter, J ;
Pache, J ;
Schühlen, H ;
Schmitt, C ;
Dirschinger, J ;
Schömig, A .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (02) :165-171
[7]   In-stent restenosis: Contributions of inflammatory responses and arterial injury to neointimal hyperplasia [J].
Kornowski, R ;
Hong, MK ;
Tio, FO ;
Bramwell, O ;
Wu, HS ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (01) :224-230
[8]   Preclinical Models of Restenosis and Their Application in the Evaluation of Drug-Eluting Stent Systems [J].
Perkins, L. E. Leigh .
VETERINARY PATHOLOGY, 2010, 47 (01) :58-76
[9]   Paclitaxel balloon coating, a novel method for prevention and therapy of restenosis [J].
Scheller, B ;
Speck, U ;
Abramjuk, C ;
Bernhardt, U ;
Böhm, M ;
Nickenig, G .
CIRCULATION, 2004, 110 (07) :810-814
[10]   Addition of paclitaxel to contrast media prevents restenosis after coronary stent implantation [J].
Scheller, B ;
Speck, U ;
Schmitt, A ;
Böhm, M ;
Nickenig, G .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (08) :1415-1420