Comparing approaches to screening for angle closure in older Chinese adults

被引:7
作者
Andrews, J. [2 ]
Chang, D. S. [2 ,3 ]
Jiang, Y.
He, M. [1 ]
Foster, P. J. [4 ,5 ]
Munoz, B. [2 ,3 ]
Kashiwagi, K. [6 ]
Friedman, D. S. [2 ,3 ]
机构
[1] Sun Yat Sen Univ, Dept Prevent Ophthalmol, Zhongshan Ophthalm Ctr, Guangzhou 510060, Guangdong, Peoples R China
[2] Johns Hopkins Bloomberg Sch Publ Hlth, Baltimore, MD USA
[3] Johns Hopkins Sch Med, Wilmer Eye Inst, Baltimore, MD USA
[4] UCL Inst Ophthalmol, NIHR Biomed Res Ctr Ophthalmol, London, England
[5] Moorfields Eye Hosp, London, England
[6] Univ Yamanashi, Dept Ophthalmol, Yamanashi, Japan
关键词
glaucoma; angle closure; diagnostic techniques; ophthalmological; gonioscopy; CHAMBER DEPTH ANALYZER; ANTERIOR-CHAMBER; GLAUCOMA; POPULATION; SEGMENT; SYSTEM;
D O I
10.1038/eye.2011.244
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims Primary angle-closure glaucoma is expected to account for nearly 50% of bilateral glaucoma blindness by 2020. This study was conducted to assess the performance of the scanning peripheral anterior chamber depth analyzer (SPAC) and limbal anterior chamber depth (LACD) as screening methods for angle closure. Methods This study assessed two clinical populations to compare SPAC, LACD, and gonioscopy: the Zhongshan Angle-closure Prevention Trial, from which 370 patients were eligible as closed-angle participants and the Liwan Eye Study, from which 72 patients were selected as open-angle controls. Eligible participants were assessed by SPAC, LACD, and gonioscopy. Results Angle status was defined by gonioscopy. Area under the receiver operating characteristic curve (AUROC) for SPAC was 0.92 (0.89-0.95) whereas AUROC for LACD was 0.94 (0.92-0.97). Using conventional cutoff points, sensitivity/specificity was 93.0%/70.8% for SPAC and 94.1%/87.5% for LACD. Sequential testing using both SPAC and LACD increased the specificity to 94.4% and decreased the sensitivity to 87.0%. Conclusion SPAC has significantly lower specificity than LACD measurement using conventional cutoffs but interpretation of the findings can be performed by modestly trained personnel. Eye (2012) 26, 96-100; doi:10.1038/eye.2011.244; published online 14 October 2011
引用
收藏
页码:96 / 100
页数:5
相关论文
共 18 条
[11]   Comparison of anterior chamber depth measurements using the IOLMaster, scanning peripheral anterior chamber depth analyser, and anterior segment optical coherence tomography [J].
Lavanya, Raghavan ;
Teo, Livia ;
Friedman, David S. ;
Aung, Han T. ;
Baskaran, Mani ;
Gao, Hong ;
Alfred, Tamuno ;
Seah, Steve K. ;
Kashiwagi, Kenji ;
Foster, Paul J. ;
Aung, Tin .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (08) :1023-1026
[12]   The number of people with glaucoma worldwide in 2010 and 2020 [J].
Quigley, HA ;
Broman, AT .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (03) :262-267
[13]   Evaluation of practice patterns for the care of open-angle glaucoma compared with claims data - The glaucoma adherence and persistency study [J].
Quigley, Harry A. ;
Friedman, David S. ;
Hahn, Steven R. .
OPHTHALMOLOGY, 2007, 114 (09) :1599-1606
[14]  
Resnikoff S, 2004, B WORLD HEALTH ORGAN, V82, P844
[15]   Imaging of the anterior segment in glaucoma [J].
See, Jovina Li Shuen .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 37 (05) :506-513
[16]  
Shaffer RN., 1962, STEREOSCOPIC MANUAL
[17]  
Spaeth GL, 2008, T OPHTHAL SOC UK, V91, P710
[18]   ESTIMATION OF WIDTH OF ANGLE OF ANTERIOR CHAMBER - INCIDENCE AND SIGNIFICANCE OF NARROW ANGLE [J].
VANHERICK, W ;
SHAFFER, RN ;
SCHWARTZ, A .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1969, 68 (04) :626-+