Comparing approaches to screening for angle closure in older Chinese adults

被引:7
作者
Andrews, J. [2 ]
Chang, D. S. [2 ,3 ]
Jiang, Y.
He, M. [1 ]
Foster, P. J. [4 ,5 ]
Munoz, B. [2 ,3 ]
Kashiwagi, K. [6 ]
Friedman, D. S. [2 ,3 ]
机构
[1] Sun Yat Sen Univ, Dept Prevent Ophthalmol, Zhongshan Ophthalm Ctr, Guangzhou 510060, Guangdong, Peoples R China
[2] Johns Hopkins Bloomberg Sch Publ Hlth, Baltimore, MD USA
[3] Johns Hopkins Sch Med, Wilmer Eye Inst, Baltimore, MD USA
[4] UCL Inst Ophthalmol, NIHR Biomed Res Ctr Ophthalmol, London, England
[5] Moorfields Eye Hosp, London, England
[6] Univ Yamanashi, Dept Ophthalmol, Yamanashi, Japan
关键词
glaucoma; angle closure; diagnostic techniques; ophthalmological; gonioscopy; CHAMBER DEPTH ANALYZER; ANTERIOR-CHAMBER; GLAUCOMA; POPULATION; SEGMENT; SYSTEM;
D O I
10.1038/eye.2011.244
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims Primary angle-closure glaucoma is expected to account for nearly 50% of bilateral glaucoma blindness by 2020. This study was conducted to assess the performance of the scanning peripheral anterior chamber depth analyzer (SPAC) and limbal anterior chamber depth (LACD) as screening methods for angle closure. Methods This study assessed two clinical populations to compare SPAC, LACD, and gonioscopy: the Zhongshan Angle-closure Prevention Trial, from which 370 patients were eligible as closed-angle participants and the Liwan Eye Study, from which 72 patients were selected as open-angle controls. Eligible participants were assessed by SPAC, LACD, and gonioscopy. Results Angle status was defined by gonioscopy. Area under the receiver operating characteristic curve (AUROC) for SPAC was 0.92 (0.89-0.95) whereas AUROC for LACD was 0.94 (0.92-0.97). Using conventional cutoff points, sensitivity/specificity was 93.0%/70.8% for SPAC and 94.1%/87.5% for LACD. Sequential testing using both SPAC and LACD increased the specificity to 94.4% and decreased the sensitivity to 87.0%. Conclusion SPAC has significantly lower specificity than LACD measurement using conventional cutoffs but interpretation of the findings can be performed by modestly trained personnel. Eye (2012) 26, 96-100; doi:10.1038/eye.2011.244; published online 14 October 2011
引用
收藏
页码:96 / 100
页数:5
相关论文
共 18 条
[1]   Comparison of the scanning peripheral anterior chamber depth analyzer and the modified van Herick grading system in the assessment of angle closure [J].
Baskaran, Mani ;
Oen, Francis T. S. ;
Chan, Yiong-Huak ;
Hoh, Sek-Tien ;
Ho, Ching-Lin ;
Kashiwagi, Kenji ;
Foster, Pau J. ;
Aung, Tin .
OPHTHALMOLOGY, 2007, 114 (03) :501-506
[2]   Detection of gonioscopically occludable angles and primary angle closure glaucoma by estimation of limbal chamber depth in Asians: modified grading scheme [J].
Foster, PJ ;
Devereux, JG ;
Alsbirk, PH ;
Lee, PS ;
Uranchimeg, D ;
Machin, D ;
Johnson, GJ ;
Baasanhu, J .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2000, 84 (02) :186-192
[3]   Glaucoma in China: how big is the problem? [J].
Foster, PJ ;
Johnson, GJ .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (11) :1277-1282
[4]   Anterior chamber angle assessment techniques [J].
Friedman, David S. ;
He, Mingguang .
SURVEY OF OPHTHALMOLOGY, 2008, 53 (03) :250-273
[5]   Prevalence and clinical characteristics of glaucoma in adult Chinese: A population-based study in Liwan District, Guangzhou [J].
He, Mingguang ;
Foster, Paul J. ;
Ge, Jian ;
Huang, Wenyong ;
Zheng, Yingfeng ;
Friedman, David S. ;
Lee, Pak Sang ;
Khaw, Peng T. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (07) :2782-2788
[6]   Design and Methodology of a Randomized Controlled Trial of Laser Iridotomy for the Prevention of Angle Closure in Southern China: The Zhongshan Angle Closure Prevention Trial [J].
Jiang, Yuzhen ;
Friedman, David S. ;
He, Mingguang ;
Huang, Shengsong ;
Kong, Xiangbin ;
Foster, Paul J. .
OPHTHALMIC EPIDEMIOLOGY, 2010, 17 (05) :321-332
[7]   A newly developed peripheral anterior chamber depth analysis system: principle, accuracy, and reproducibility [J].
Kashiwagi, K ;
Kashiwagi, F ;
Toda, Y ;
Osada, K ;
Tsumura, T ;
Tsukahara, S .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (08) :1030-1035
[8]   Case finding of angle closure glaucoma in public health examination with scanning peripheral anterior chamber depth Analyzer [J].
Kashiwagi, Kenji ;
Tsukahara, Shigeo .
JOURNAL OF GLAUCOMA, 2007, 16 (07) :589-593
[9]   Comparison between newly developed scanning peripheral anterior chamber depth analyzer and conventional methods of evaluating anterior chamber configuration [J].
Kashiwagi, Kenji ;
Tsumura, Toyoaki ;
Tsukahara, Shigeo .
JOURNAL OF GLAUCOMA, 2006, 15 (05) :380-387
[10]   Screening of narrow angles in the Singapore population: Evaluation of new noncontact screening methods [J].
Lavanya, Raghavan ;
Foster, Paul J. ;
Sakata, Lisandro M. ;
Friedman, David S. ;
Kashiwagi, Kenji ;
Wong, Tien-Yin ;
Aung, Han T. ;
Alfred, Tamuno ;
Gao, Hong ;
Ee, Adrian G. ;
Seah, Steve K. ;
Aung, Tin .
OPHTHALMOLOGY, 2008, 115 (10) :1720-1727