Mass flow measurement of pneumatically conveyed solids using electrical capacitance tomography

被引:33
作者
Sun, Meng [1 ]
Liu, Shi [2 ]
Lei, Jing [1 ]
Li, Zhihong [1 ]
机构
[1] Chinese Acad Sci, Inst Engn Thermophys, Beijing 100080, Peoples R China
[2] N China Elect Power Univ, Sch Energy & Power Engn, Beijing 102206, Peoples R China
关键词
mass flow measurement; cross-correlation; volume concentration; electrical capacitance tomography;
D O I
10.1088/0957-0233/19/4/045503
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper describes a measurement system for mass flow measurement in a pneumatic pipeline. The system mainly consists of a volumetric concentration sensor and a velocity sensor. The concentration sensor is an electrical capacitance sensor which has eight electrodes; the velocity sensor is based on cross-correlating two signals derived from a pair of capacitance sensors. A cyclone is employed in this system where the sensors are placed in order to compensate the inhomogeneity of the sensor sensitivity. Experimental results obtained on a pneumatic conveyer circulating coal ash demonstrate that this system is capable of detecting various velocity profiles and solids distributions and providing an absolute mass flow rate of solids within a good agreement with the reference reading from load cells.
引用
收藏
页数:6
相关论文
共 22 条
[1]   Mass flow measurement of pneumatically conveyed solids using radiometric sensors [J].
Barratt, IR ;
Yan, Y ;
Byrne, B ;
Bradley, MSA .
FLOW MEASUREMENT AND INSTRUMENTATION, 2000, 11 (03) :223-235
[2]  
Beck M.S., 1987, Cross Correlation Flowmeters: Their Design and Application
[3]   MEASUREMENT OF PARTICLE-VELOCITY DISTRIBUTION IN A VERTICAL CHANNEL [J].
DYAKOWSKI, T ;
WILLIAMS, RA .
POWDER TECHNOLOGY, 1993, 77 (02) :135-142
[4]   Measurement of local particle velocities and velocity distributions in gas-solid flows by means of the spatial filter method [J].
Fiedler, O ;
Werther, J ;
Labahn, N ;
Kumpart, J ;
Christofori, K .
POWDER TECHNOLOGY, 1997, 94 (01) :51-57
[5]   Optical fibre sensors for process tomography [J].
Green, RG ;
Horbury, NM ;
Rahim, RA ;
Dickin, FJ ;
Naylor, BD ;
Pridmore, TP .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1995, 6 (12) :1699-1704
[6]  
HAYES DG, 1993, TOMOGRAPHIC TECHNIQUES FOR PROCESS DESIGN AND OPERATION, P369
[7]   A novel capacitive system for the concentration measurement of pneumatically conveyed pulverized fuel at power stations [J].
Hu, HL ;
Xu, TM ;
Hui, SE ;
Zhou, QL .
FLOW MEASUREMENT AND INSTRUMENTATION, 2006, 17 (02) :87-92
[8]  
LI CX, 1996, HUAZHONG LIGONG DAXU, V24, P88
[9]   Prior-online iteration for image reconstruction with electrical capacitance tomography [J].
Liu, S ;
Fu, L ;
Yang, WQ ;
Wang, HG ;
Jiang, F .
IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2004, 151 (03) :195-200
[10]   Optimization of an iterative image reconstruction algorithm for electrical capacitance tomography [J].
Liu, S ;
Fu, L ;
Yang, WQ .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1999, 10 (07) :L37-L39