Evaluation of detection and sample clean-up techniques for on- and off-line fermentation monitoring systems

被引:14
作者
Buttler, T [1 ]
Liden, H [1 ]
Jonsson, JA [1 ]
Gorton, L [1 ]
MarkoVarga, G [1 ]
Jeppsson, H [1 ]
机构
[1] LUND UNIV,LUND INST TECHNOL,DEPT APPL MICROBIOL,S-22100 LUND,SWEDEN
关键词
biosensors; fermentation processes; carbohydrates; microdialysis; sample clean-up;
D O I
10.1016/0003-2670(96)00024-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two different analytical systems for monitoring of fermentation processes were evaluated for the analysis of three carbohydrates: glucose, xylose and galactose. Samples taken during a controlled fermentation of the three sugars to ethanol were treated and analysed with both systems for the carbohydrate content. The first was an off-line system, based on manual sampling and clean-up, and column liquid chromatography (LC) in combination with refractive index (RI) detection and the other was an on-line set-up, based on microdialysis sampling, LC and an amperometric carbohydrate biosensor as the detection device. The manual clean-up consisted of centrifugation, filtration of the supernatant and dilution. First, the different clean-up procedures were compared, and the other parts of the system were kept constant, viz. the LC separation and the RI detector, Evaluation of the analysis response using the two clean-up procedures yielded in 12 of 13 cases higher values for the microdialysis probe than for the manual procedure. Two different statistical methods, one based on linear regression and another, a paired t-test, found the difference between the two clean-up procedures to be statistically significant. Detailed investigation of the manual clean-up procedure using analysis of variance (ANOVA) revealed that for identical samples treated by this method, a significant difference in-between the samples after treatment was found. Next, the two detection techniques were compared, using the manual clean-up procedure in combination with LC. It was found that the sugar content in 15 out of 16 samples was higher for the RI detector than for the biosensor and also in this case both the linear regression method and the paired t-test showed the difference to be statistically significant. Finally, studies on the performance of microdialysis probe membranes after use in a fermentation medium are presented.
引用
收藏
页码:103 / 113
页数:11
相关论文
共 28 条
  • [1] ENZYMATIC DETERMINATION OF GLUCOSE IN A FLOW SYSTEM BY CATALYTIC-OXIDATION OF THE NICOTINAMIDE COENZYME AT A MODIFIED ELECTRODE
    APPELQVIST, R
    MARKOVARGA, G
    GORTON, L
    TORSTENSSON, A
    JOHANSSON, G
    [J]. ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) : 237 - 247
  • [2] Membrane characterisation and performance of microdialysis probes intended for use as bioprocess sampling units
    Buttler, T
    Nilsson, C
    Gorton, L
    MarkoVarga, G
    Laurell, T
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1996, 725 (01) : 41 - 56
  • [3] MONITORING OF ETHANOL DURING FERMENTATION OF A LIGNOCELLULOSE HYDROLYSATE BY ONLINE MICRODIALYSIS SAMPLING, COLUMN LIQUID-CHROMATOGRAPHY, AND AN ALCOHOL BIOSENSOR
    BUTTLER, T
    GORTON, L
    JARSKOG, H
    MARKOVARGA, G
    HAHNHAGERDAL, B
    MEINANDER, N
    OLSSON, L
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1994, 44 (03) : 322 - 328
  • [4] BUTTLER T, 1994, INT CHROMATOGR LAB, V23, P12
  • [5] ONLINE FERMENTATION PROCESS MONITORING OF CARBOHYDRATES AND ETHANOL USING TANGENTIAL FLOW FILTRATION AND COLUMN LIQUID-CHROMATOGRAPHY
    BUTTLER, TA
    JOHANSSON, KAJ
    GORTON, LGO
    MARKOVARGA, GA
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (19) : 2628 - 2636
  • [6] DINCER AK, 1984, DEV IND MICROBIOL, V25, P603
  • [7] A CONTINUOUS METHOD FOR MONITORING AND CONTROLLING FERMENTATIONS - USING AN AUTOMATED HPLC SYSTEM
    DINWOODIE, RC
    MEHNERT, DW
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1985, 27 (07) : 1060 - 1062
  • [8] STABILIZATION OF ANALYTICAL ENZYMES USING A NOVEL POLYMER CARBOHYDRATE SYSTEM AND THE PRODUCTION OF A STABILIZED, SINGLE REAGENT FOR ALCOHOL ANALYSIS
    GIBSON, TD
    HIGGINS, IJ
    WOODWARD, JR
    [J]. ANALYST, 1992, 117 (08) : 1293 - 1297
  • [9] AMPEROMETRIC BIOSENSORS BASED ON AN APPARENT DIRECT ELECTRON-TRANSFER BETWEEN ELECTRODES AND IMMOBILIZED PEROXIDASES - PLENARY LECTURE
    GORTON, L
    JONSSONPETTERSSON, G
    CSOREGI, E
    JOHANSSON, K
    DOMINGUEZ, E
    MARKOVARGA, G
    [J]. ANALYST, 1992, 117 (08) : 1235 - 1241
  • [10] HAHNHAGERDAL B, 1994, APPL MICROBIOL BIOT, V41, P62, DOI 10.1007/s002530050108