Comparative evaluation of refractive surgery candidates with Placido topography, Orbscan II, Pentacam, and Wavefront analysis

被引:78
作者
Nilforoushan, Mohammad-Reza
Speaker, Mark [1 ]
Marmor, Michael [2 ]
Abramson, Jodi
Tullo, William
Morschauser, Dana
Latkany, Robert
机构
[1] New York Eye & Ear Infirm, New York, NY 10003 USA
[2] NYU, New York, NY USA
关键词
D O I
10.1016/j.jcrs.2007.11.054
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To study the role of the Pentacam (Oculus), Orbscan II (Bausch & Lomb), and WaveScan (Visx) in evaluating topographic features identified as risk factors for ectasia after laser in situ keratomileusis to identify parameters that may be important in interpreting elevation topography and wavefront data when screening refractive surgery candidates. SETTING: Private practice, New York, New York, USA. METHODS: One hundred forty-five eyes of 75 consecutive patients were evaluated for refractive surgery by ultrasound pachymetry (Humphrey Atlas), videokeratography, WaveScan, Orbscan II, and Pentacam. Eyes were classified as normal or suspect based on the Rabinowitz criteria for keratoconus suspect on Placido disk-based videokeratography. Forty-six parameters were evaluated in a comparison of topographically normal eyes and eyes that met the criteria for keratoconus suspect. RESULTS: The suspect group had thinner pachymetry, multiple distinguishing characteristics on the anterior and posterior corneal surfaces by elevation topography, and larger amounts of coma by wavefront analysis. Multivariable regression analysis identified the following as the strongest predictors of a suspect Placido topography: Pentacam, thinner pachymetry and larger differences between the highest and lowest points on the posterior elevation; Orbscan II, higher anterior maximum elevation, horizontal location of the thinnest point on the pachymetry map, and larger differences between the highest and lowest points on the posterior elevation. CONCLUSION: Several parameters provided by the Pentacam, Orbscan II, WaveScan, and pachymetry were statistically correlated with keratoconus suspect, defined by higher asymmetry and steeper curvature on Placido topography.
引用
收藏
页码:623 / 631
页数:9
相关论文
共 19 条
[1]  
Ambrosio R, 2003, J REFRACT SURG, V19, P24
[2]   Keratoconus evaluation using the Orbscan Topography System [J].
Auffarth, GU ;
Wang, L ;
Völcker, HE .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (02) :222-228
[3]   Ectasia after laser in situ keratomileusis [J].
Binder, PS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (12) :2419-2429
[4]  
Binder PS, 2005, J REFRACT SURG, V21, P749
[5]   Orbscan computerized topography: Attributes, applications, and limitations [J].
Cairns, G ;
McGhee, CNJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :205-220
[6]   PRK in patients with a keratoconic topography picture. The concept of a physiological 'displaced apex syndrome' [J].
Doyle, SJ ;
Hynes, E ;
Naroo, S ;
Shah, S .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1996, 80 (01) :25-28
[7]   Corneal ectasia after laser in situ keratomileusis in patients without apparent preoperative risk factors [J].
Klein, Shawn R. ;
Epstein, Randy J. ;
Randleman, J. Bradley ;
Stulting, R. Doyle .
CORNEA, 2006, 25 (04) :388-403
[8]  
Krachmer J. H., 2011, CORNEA, V3rd
[9]   Videokeratographic anomalies in familial keratoconus [J].
Levy, D ;
Hutchings, H ;
Rouland, JF ;
Guell, J ;
Burillon, C ;
Arné, JL ;
Colin, J ;
Laroche, L ;
Montard, M ;
Delbosc, B ;
Aptel, I ;
Ginisty, H ;
Grandjean, H ;
Malecaze, F .
OPHTHALMOLOGY, 2004, 111 (05) :867-874
[10]   Wavefront aberrations measured with Hartmann-Shack sensor in patients with keratoconus [J].
Maeda, N ;
Fujikado, T ;
Kuroda, T ;
Mihashi, T ;
Hirohara, Y ;
Nishida, K ;
Watanabe, H ;
Tano, Y .
OPHTHALMOLOGY, 2002, 109 (11) :1996-2003