Power cables models with frequency dependent parameters

被引:0
|
作者
Weens, Y. [1 ]
Idir, N. [1 ]
Franchaud, J. J. [1 ]
机构
[1] Univ Sci & Technologies Lille, Lab Electrotech & Elect Puissance L2EP Lille, UFR IEEA, F-59655 Villeneuve Dascq, France
关键词
power cables; modeling; power electronics; adjustable speed drives; EMI;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The fast commutation of the modern power semi-conductor devices is the main source of the conducted and radiated emissions generated by the power converters. These devices produce high voltage variations (dv/dt) which excite stray elements of the power circuit and induce high frequency parasitical currents that use the energy cables to be propagated in the whole of the system. In order to study the influence of the power cable characteristics on the level of the conducted emissions, it is necessary to elaborate a precise model of the energy cables, taking into account various phenomena that appear when the frequency increases. This paper proposes a high frequency modelling method of energy cable that takes into account the skin and proximity effects and dielectric losses. The proposed method is applied to the 3-wire unshielded cable and extended to the 4-wire shielded cable. The proposed models are validated in the frequency and time domains. Copyright (C) 2007 Praise Worthy Prize S.r.l. - All rights reserved.
引用
收藏
页码:763 / 770
页数:8
相关论文
共 50 条
  • [21] Skin Effect and Dielectric Loss Models of Power Cables
    Idir, Nadir
    Weens, Yannick
    Franchaud, Jean-Jacques
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (01) : 147 - 154
  • [22] EMP Coupling to Buried Cables in the Frequency-Dependent Soil
    Jiang Wenwen
    Shi Lihua
    Huang Zhengyu
    2015 7TH ASIA-PACIFIC CONFERENCE ON ENVIRONMENTAL ELECTROMAGNETICS (CEEM), 2015, : 225 - 229
  • [23] Frequency-Dependent Coupled Field-Circuit Modeling of Armored Power Cables Using Finite Elements
    Abed, Nagy Y.
    Mohammed, Osama A.
    IEEE TRANSACTIONS ON MAGNETICS, 2011, 47 (05) : 930 - 933
  • [24] Frequency stability assessment of modern power systems: Models definition and parameters identification
    Conte, Francesco
    Massucco, Stefano
    Paolone, Mario
    Schiapparelli, Giacomo Piero
    Silvestro, Federico
    Zuo, Yihui
    SUSTAINABLE ENERGY GRIDS & NETWORKS, 2020, 23
  • [25] Experimentally verified, temperature dependent physical models/parameters for power device simulation
    Isberg, M.
    Jonsson, P.
    Masszi, F.
    Vojdani, F.
    Bleichner, H.
    Rosling, M.
    Nordlander, E.
    IEEE International Symposium on Power Semiconductor Devices & ICs, 1994, : 281 - 286
  • [26] Efficient time-domain numerical modelling of crosstalk between coaxial cables incorporating frequency-dependent parameters
    Teo, Yu Xian
    Thomas, David W. P.
    Christopoulos, Christos
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2020, 14 (04) : 387 - 395
  • [27] PARAMETERS OF CURRENT RATINGS OF NATURALLY COOLED POWER-CABLES
    BRAKELMANN, H
    ETZ ARCHIV, 1981, 3 (05): : 157 - 159
  • [28] TECHNOLOGICAL PARAMETERS OF THE COOLING MODE OF POLYMER INSULATION OF POWER CABLES
    Bezprozvannych, G., V
    Mirchuk, I. A.
    Kyessayev, A. G.
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2019, (03) : 44 - 49
  • [29] SCREEN SELECTION FOR THE POWER FREQUENCY MAGNETIC FIELD SHIELDING OF UNDERGROUND POWER CABLES
    Carlos del Pina-López, Juan
    Cruz-Romero, Pedro
    Bachiller-Soler, Alfonso
    DYNA, 2013, 88 (01): : 105 - 113
  • [30] Frequency-Domain Propagation in Multiconductor Submarine Power Cables
    Coelho, Rooney R. A.
    Biage, Gabriel de Castro
    Filho, Mario Leite P.
    Cardoso, Jose Roberto
    IEEE TRANSACTIONS ON MAGNETICS, 2024, 60 (09) : 1 - 1