Spectral fingerprinting: microstate readout via remanence ferromagnetic resonance in artificial spin ice

被引:10
|
作者
Vanstone, Alex [1 ,2 ]
Gartside, Jack C. [1 ]
Stenning, Kilian D. [1 ]
Dion, Troy [2 ,3 ]
Arroo, Daan M. [2 ,4 ]
Branford, Will R. [1 ,5 ]
机构
[1] Imperial Coll London, Blackett Lab, London SW7 2AZ, England
[2] UCL, London Ctr Nanotechnol, London WC1H 0AH, England
[3] Kyushu Univ, Solid State Phys Lab, Nishi Ku, 744 Motooka, Fukuoka 8190395, Japan
[4] Imperial Coll London, Dept Mat, London SW7 2AZ, England
[5] Imperial Coll London, London Ctr Nanotechnol, London SW7 2AZ, England
来源
NEW JOURNAL OF PHYSICS | 2022年 / 24卷 / 04期
基金
英国工程与自然科学研究理事会;
关键词
artificial spin ice; magnonics; magnetic microstates; ferromagnetic resonance; nanomagnetism; nanostructures; STATE;
D O I
10.1088/1367-2630/ac608b
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Artificial spin ices (ASIs) are magnetic metamaterials comprising geometrically tiled strongly-interacting nanomagnets. There is significant interest in these systems spanning the fundamental physics of many-body systems to potential applications in neuromorphic computation, logic, and recently reconfigurable magnonics. Magnonics focused studies on ASI have to date have focused on the in-field GHz spin-wave response, convoluting effects from applied field, nanofabrication imperfections ('quenched disorder') and microstate-dependent dipolar field landscapes. Here, we investigate zero-field measurements of the spin-wave response and demonstrate its ability to provide a 'spectral fingerprint' of the system microstate. Removing applied field allows deconvolution of distinct contributions to reversal dynamics from the spin-wave spectra, directly measuring dipolar field strength and quenched disorder as well as net magnetisation. We demonstrate the efficacy and sensitivity of this approach by measuring ASI in three microstates with identical (zero) magnetisation, indistinguishable via magnetometry. The zero-field spin-wave response provides distinct spectral fingerprints of each state, allowing rapid, scaleable microstate readout. As artificial spin systems progress toward device implementation, zero-field functionality is crucial to minimize the power consumption associated with electromagnets. Several proposed hardware neuromorphic computation schemes hinge on leveraging dynamic measurement of ASI microstates to perform computation for which spectral fingerprinting provides a potential solution.
引用
收藏
页数:12
相关论文
共 47 条
  • [41] Non-local detection of spin dynamics via spin rectification effect in yttrium iron garnet/SiO2/NiFe trilayers near simultaneous ferromagnetic resonance
    Soh, Wee Tee
    Peng, Bin
    Ong, C. K.
    AIP ADVANCES, 2015, 5 (08):
  • [42] Magnetocrystalline anisotropy and spin-wave stiffness in tensilestrained La0.67Ba0.33MnO3 films:An investigation via ferromagnetic resonance
    DUANMU QingYong
    TONG Wei
    YANG Lei
    HAO Lin
    ZHANG ZhongFeng
    WANG XiaoPing
    ZHU Hong
    ChineseScienceBulletin, 2013, 58 (33) : 4057 - 4063
  • [43] Measurement of spin mixing conductance in Ni81Fe19/α-W and Ni81Fe19/β-W heterostructures via ferromagnetic resonance
    Cao, W.
    Liu, J.
    Zangiabadi, A.
    Barmak, K.
    Bailey, W. E.
    JOURNAL OF APPLIED PHYSICS, 2019, 126 (04)
  • [44] Magnetocrystalline anisotropy and spin-wave stiffness in tensile-strained La0.67Ba0.33MnO3 films: An investigation via ferromagnetic resonance
    Duanmu QingYong
    Tong Wei
    Yang Lei
    Hao Lin
    Zhang ZhongFeng
    Wang XiaoPing
    Zhu Hong
    CHINESE SCIENCE BULLETIN, 2013, 58 (33): : 4057 - 4063
  • [45] RETRACTED: Improving signal-to-noise ratio of magnetic tunnel junction based radio frequency detector via spin-torque ferromagnetic resonance (Retracted Article)
    Tiwari, Dhananjay
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (05):
  • [46] Simultaneous Emission Spectral Narrowing and Spin-Flip Acceleration in Multi-Resonance Organoboron Emitters via Sequential Indolo-Fusion π-Extension
    Min, Hyukgi
    Yasuda, Takuma
    ADVANCED OPTICAL MATERIALS, 2025,
  • [47] RETRACTION: Improving signal-to-noise ratio of magnetic tunnel junction based radio frequency detector via spin-torque ferromagnetic resonance (Retraction of Vol 93, art no 053904, 2022)
    Tiwari, Dhananjay
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (09):