Effect of rectangular hot water tank position and aspect ratio on thermal stratification enhancement

被引:44
作者
Kursun, Burak [1 ]
Okten, Korhan [1 ]
机构
[1] Amasya Univ, Technol Fac, Dept Mech Engn, TR-05100 Amasya, Turkey
关键词
Energy storage; Natural convection; Thermal stratification; Water tank; STORAGE TANK; NATURAL-CONVECTION; INLET; OBSTACLES;
D O I
10.1016/j.renene.2017.10.013
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Thermal stratification is an important factor increasing the efficiency of hot water storage tanks used for thermal energy storage. In this study, the effects of the position of a rectangular hot water tank and the aspect ratio on the thermal stratification were investigated numerically. In this direction, a numerical analysis was carried out for the different angle of the water tank with the horizontal axis (alpha) and the different aspect ratio of the water tank (D/H). Numerical analyses were performed at 0-60 degrees range of angle values and 0.5-1 range of aspect ratio values. The results obtained from the analyses indicate that positioning of the hot water tank at different values from alpha = 0 degrees provides thermal stratification enhancement. Reducing the aspect ratio of the tank contributes to the thermal stratification only for the angle of alpha = 0 degrees significantly. In other angle values, the influence of different aspect ratios on the thermal stratification is negligible level. The highest temperature difference in the hot water tank occurred for the angle of alpha = 45 degrees and aspect ratio of D/H = 0.5. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:639 / 646
页数:8
相关论文
共 19 条
[1]   CFD analysis of thermal stratification in domestic hot water storage tank during dynamic mode [J].
Abdelhak, Olfa ;
Mhiri, Hatem ;
Bournot, Philippe .
BUILDING SIMULATION, 2015, 8 (04) :421-429
[2]   Effect of obstacles on thermal stratification in hot water storage tanks [J].
Altuntop, N ;
Arslan, M ;
Ozceyhan, V ;
Kanoglu, M .
APPLIED THERMAL ENGINEERING, 2005, 25 (14-15) :2285-2298
[3]  
ANSYS, 2013, ANSYS FLUENT THEOR G, P514
[4]   THE PRANDTL NUMBER EFFECT ON THE TRANSITION IN NATURAL-CONVECTION ALONG A VERTICAL SURFACE [J].
BEJAN, A ;
LAGE, JL .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1990, 112 (03) :787-790
[5]   Numerical modeling and optimization of thermal stratification in solar hot water storage tanks for domestic applications: CFD study [J].
Bouhal, T. ;
Fertahi, S. ;
Agrouaz, Y. ;
El Rhafiki, T. ;
Kousksou, T. ;
Jamil, A. .
SOLAR ENERGY, 2017, 157 :441-455
[6]  
Cengel Y. A., 2006, HEAT MASS TRANSF PRA, V3, P72
[7]   The effect of diffuser configuration on thermal stratification in a rectangular storage tank [J].
Chung, Jae Dong ;
Cho, Sung Hwan ;
Tae, Choon Seob ;
Yoo, Hoseon .
RENEWABLE ENERGY, 2008, 33 (10) :2236-2245
[8]   Thermal stratification built up in hot water tank with different inlet stratifiers [J].
Dragsted, Janne ;
Furbo, Simon ;
Dannemand, Mark ;
Bava, Federico .
SOLAR ENERGY, 2017, 147 :414-425
[9]   Improved thermal stratification with obstacles placed inside the vertical mantled hot water tanks [J].
Erdemir, Dogan ;
Altuntop, Necdet .
APPLIED THERMAL ENGINEERING, 2016, 100 :20-29
[10]   Experimental analysis of a domestic electric hot water storage tank.: Part I:: Static mode of operation [J].
Fernandez-Seara, Jose ;
Uhia, Francisco J. ;
Sieres, Jaime .
APPLIED THERMAL ENGINEERING, 2007, 27 (01) :129-136