Flow injection chemiluminescent determination of N-nitrosodimethylamine using photogenerated tris(2,2′-bipyridyl) ruthenium (III)

被引:21
作者
Pérez-Ruiz, T [1 ]
Martínez-Lozano, C [1 ]
Tomás, V [1 ]
Martín, J [1 ]
机构
[1] Univ Murcia, Fac Chem, Dept Analyt Chem, E-30071 Murcia, Spain
关键词
nitrosamines; chemiluminescence; flow-injection; tris(2,2 '-bipyridyl) ruthenium (III) photogenerated;
D O I
10.1016/j.aca.2004.08.051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection configuration was developed and evaluated for the chemiluminescent determination of N-nitrosodimethylamine. The method is based on the on-line cleavage of the N-NO bond of the nitrosamine by irradiation with ultraviolet light. The dimethylamine generated was subsequently reacted with tris(2,2'-bipyridyl) ruthenium (III), which was generated through the on-line photo-oxidation of tris(2,2'-bipyridyl) ruthenium (II) with peroxydisulfate. After selecting the best operating parameters, the emitted light showed a linear relationship with the concentration of N-nitrosodimethylamine between 1.5 and 148 no ml(-1), with a detection limit of 0.29 no ml(-1). The repeatability was 1.6% expressed as relative standard deviation (n = 10) and the reproducibility, studied on five consecutive days, was 3.2%. The sample throughput was 50 injections per hour. The method was applied to studying the recoveries of N-nitrosodimethylamine in water and different cured meat products. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:69 / 74
页数:6
相关论文
共 38 条
[1]   Determination of flufenamic acid and mefenamic acid in pharmaceutical preparations and biological fluids using flow injection analysis with tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection [J].
Aly, FA ;
Al-Tamimi, SA ;
Alwarthan, AA .
ANALYTICA CHIMICA ACTA, 2000, 416 (01) :87-96
[2]   TRANSFORMATIONS OF METHYLAMINES AND FORMATION OF A HAZARDOUS PRODUCT, DIMETHYLNITROSAMINE, IN SAMPLES OF TREATED SEWAGE AND LAKE WATER [J].
AYANABA, A ;
ALEXANDER, M .
JOURNAL OF ENVIRONMENTAL QUALITY, 1974, 3 (01) :83-89
[3]   Determination of ranitidine and salbutamol by flow injection analysis with chemiluminescence detection [J].
Barnett, NW ;
Hindson, BJ ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 1999, 384 (02) :151-158
[4]   Determination of codeine in process streams using flow-injection analysis with chemiluminescence detection [J].
Barnett, NW ;
Bowser, TA ;
Gerardi, RD ;
Smith, B .
ANALYTICA CHIMICA ACTA, 1996, 318 (03) :309-317
[5]   Fast microwave-assisted dansylation of N-nitrosamines -: Analysis by high-performance liquid chromatography with fluorescence detection [J].
Cárdenes, L ;
Ayala, JH ;
González, V ;
Afonso, AM .
JOURNAL OF CHROMATOGRAPHY A, 2002, 946 (1-2) :133-140
[6]   PHOTOREACTIONS OF NITROSO-COMPOUNDS IN SOLUTION .20. PHOTOREDUCTION, PHOTOELIMINATION, AND PHOTOADDITION OF NITROSAMINES [J].
CHOW, YL ;
TAM, JNS ;
LAU, MP ;
PERRY, RA .
CANADIAN JOURNAL OF CHEMISTRY, 1972, 50 (07) :1044-&
[7]  
CHOW YL, 1964, TETRAHEDRON LETT, V34, P2333
[8]  
DAIBER D, 1964, Z ANAL CHEM, V206, P344
[9]   DETERMINATION OF ERYTHROMYCIN IN TABLETS AND CAPSULES USING FLOW-INJECTION ANALYSIS WITH CHEMI-LUMINESCENCE DETECTION [J].
DANIELSON, ND ;
HE, L ;
NOFFSINGER, JB ;
TRELLI, L .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1989, 7 (11) :1281-1285
[10]   N-NITROSODIETHANOLAMINE IN SYNTHETIC CUTTING FLUIDS - PART-PER-HUNDRED IMPURITY [J].
FAN, TY ;
MORRISON, J ;
ROUNBEHLER, DP ;
ROSS, R ;
FINE, DH ;
MILES, W ;
SEN, NP .
SCIENCE, 1977, 196 (4285) :70-71