Continuous Real-time Viability Assessment of Kidneys Based on Oxygen Consumption

被引:19
|
作者
Weegman, B. P.
Kirchner, V. A.
Scott, W. E., III
Avgoustiniatos, E. S.
Suszynski, T. M.
Ferrer-Fabrega, J.
Rizzari, M. D. [2 ]
Kidder, L. S.
Kandaswamy, R.
Sutherland, D. E. R.
Papas, K. K. [1 ]
机构
[1] Univ Minnesota, Dept Surg, Schulze Diabet Inst, Minneapolis, MN 55455 USA
[2] Univ Texas SW Med Ctr Dallas, Dept Surg, Dallas, TX 75390 USA
关键词
MACHINE PERFUSION; INJURY; DONORS; FLOW;
D O I
10.1016/j.transproceed.2010.05.082
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. Current ex vivo quality assessment of donor kidneys is limited to vascular resistance measurements and histological analysis. New techniques for the assessment of organ quality before transplantation may further improve clinical outcomes while expanding the depleted deceased-donor pool. We propose the measurement of whole organ oxygen consumption rate (WOOCR) as a method to assess the quality of kidneys in real time before transplantation. Methods. Five porcine kidneys were procured using a donation after cardiac death (DCD) model. The renal artery and renal vein were cannulated and the kidney connected to a custom-made hypothermic machine perfusion (HMP) system equipped with an inline oxygenator and fiber-optic oxygen sensors. Kidneys were perfused at 8 degrees C, and the perfusion parameters and partial oxygen pressures (pO(2)) were measured to calculate WOOCR. Results. Without an inline oxygenator, the pO(2) of the perfusion solution at the arterial inlet and venous outlet diminished to near 0 within minutes. However, once adequate oxygenation was provided, a significant pO(2) difference was observed and used to calculate the WOOCR. The WOOCR was consistently measured from presumably healthy kidneys, and results suggest that it can be used to differentiate between healthy and purposely damaged organs. Conclusions. Custom-made HMP systems equipped with an oxygenator and inline oxygen sensors can be applied for WOOCR measurements. We suggest that WOOCR is a promising approach for the real-time quality assessment of kidneys and other organs during preservation before transplantation.
引用
收藏
页码:2020 / 2023
页数:4
相关论文
共 50 条
  • [1] Continuous, real-time viability assessment of kidneys based on oxygen consumption
    Weegman, Bradley P.
    Scott, William E., III
    Anazawa, Takayuki
    Avgoustiniatos, Efstathios S.
    Yuasa, Takeshi
    Ferrer-Fabrega, Joana
    Hammer, Bruce E.
    Loughnane, Michael H.
    Hering, Bernhard J.
    Kandaswamy, Raja
    Sutherland, David E. R.
    Suszynski, Thomas M.
    Papas, Klearchos K.
    XENOTRANSPLANTATION, 2009, 16 (05) : 432 - 433
  • [2] Continuous, real-time viability assessment of pancreata based on oxygen consuption
    Weegman, Bradley P.
    Ferrer-Fabrega, Joana
    Scott, William E., III
    Anazawa, Takayuki
    Avgoustiniatos, Efstathios S.
    Yuasa, Takeshi
    Hammer, Bruce E.
    Loughnane, Michael H.
    Hering, Bernhard J.
    Kandaswamy, Raja
    Sutherland, David E. R.
    Thomas, Suszynski M.
    Papas, Klearchos K.
    XENOTRANSPLANTATION, 2009, 16 (05) : 421 - 421
  • [3] Assessment of Anastomotic Viability With Spectroscopic Real-time Oxygen Saturation Measurement in a Porcine Study
    Khosrawipour, Tanja
    Li, Shiri
    Steward, Earl
    Chaudhry, Haris
    Nguyen, Danielle
    Khosrawipour, Veria
    Jafari, Mehraneh Dorna
    Pigazzi, Alessio
    SURGICAL INNOVATION, 2023, 30 (03) : 349 - 355
  • [4] Real-time monitoring of oxygen consumption of hepatocytes in a microbioreactor
    Uhlig, K.
    Gehre, C. P.
    Kammerer, S.
    Kuepper, J. -H.
    Coleman, D.
    Pueschel, G.
    Duschl, C.
    TOXICOLOGY LETTERS, 2018, 295 : S115 - S115
  • [5] Nondestructive Real Time Cell Viability Assessment Using Oxygen Imaging
    Hameed, S.
    Viswakarma, N.
    Siddiqui, E.
    Epel, B.
    Kotecha, M.
    TISSUE ENGINEERING PART A, 2023, 29 (9-10)
  • [6] ASSESSMENT OF ANASTOMOTIC VIABILITY WITH SPECTROSCOPIC REAL-TIME OXYGEN SATURATION MEASUREMENT: AN IN-VIVO PILOT STUDY.
    Khosrawipour, T.
    Li, S.
    Chaudhry, H.
    Khosrawipour, V.
    Jafari, M. D.
    Pigazzi, A.
    DISEASES OF THE COLON & RECTUM, 2020, 63 (06) : E235 - E235
  • [7] Letter to the Editor: The Concept of Real-Time Spectroscopy for Liver Viability Assessment
    Carvalho, Mauricio Flores
    Mueller, Matteo
    Muiesan, Paolo
    Dutkowski, Philipp
    Schlegel, Andrea
    HEPATOLOGY, 2021, 74 (04) : 2309 - 2310
  • [8] REAL-TIME ASSESSMENT PROTOCOL FOR ASSESSING ALCOHOL CONSUMPTION AND REACTIONS
    Luczak, S. E.
    Rosen, I. G.
    ALCOHOLISM-CLINICAL AND EXPERIMENTAL RESEARCH, 2011, 35 (06) : 276A - 276A
  • [9] Real-Time Control for Autonomous Racing Based on Viability Theory
    Liniger, Alexander
    Lygeros, John
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2019, 27 (02) : 464 - 478
  • [10] Noninvasive Real-Time Assessment of Cell Viability in a Three-Dimensional Tissue
    Mahfouzi, Seyed Hossein
    Amoabediny, Ghassem
    Doryab, Ali
    Safiabadi-Tali, Seyed Hamid
    Ghanei, Mostafa
    TISSUE ENGINEERING PART C-METHODS, 2018, 24 (04) : 197 - 204