New electrochemical sensors for detection of nitrites and nitrates

被引:151
作者
Badea, M
Amine, A
Palleschi, G
Moscone, D
Volpe, G
Curulli, A [1 ]
机构
[1] CNR, Ctr Studio Elettrochim & Chim Fis Interfasi, Rome, Italy
[2] Univ Bucharest, Inst Chem Res, Dept Biotechnol, Bucharest, Romania
[3] Univ Mohammadia, Fac Sci & Tech, Mohammadia, Morocco
[4] Univ Roma Tor Vergata, Dipartimento Sci & Tecnol Chim, Rome, Italy
关键词
non-conducting polymers; electropolymerisation; amperometric sensors; flow injection analysis; nitrites and nitrates detection;
D O I
10.1016/S0022-0728(01)00358-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Platinum electrodes modified with a cellulose acetate membrane or with poly(1,8-diaminonaphthalene) film were assembled and used for rapid amperometric detection of nitrites and nitrates in water by batch and flow injection analysis. Parameters such as the permeability of the electropolymerised films to nitrites and nitrates, interference effects and recovery studies of these kinds of sensors have been optimised to demonstrate the analytical suitability of the proposed method. Contrary to the standard colorimetric method, which is based on carcinogenic reagents, the amperometric detection of nitrites and nitrates is very simple and rapid and does not require any reagent for nitrite detection. Also, this method could be extended easily to the analysis of nitrites and nitrates in various types of samples such as food, soils, vegetables and fertilisers. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:66 / 72
页数:7
相关论文
共 26 条
  • [1] [Anonymous], 1995, STANDARD METHODS EXA, V19th
  • [2] Amperometric determination of nitrite via reaction with iodide using microelectrodes
    Bertotti, M
    Pletcher, D
    [J]. ANALYTICA CHIMICA ACTA, 1997, 337 (01) : 49 - 55
  • [3] COMPARISON BETWEEN ION CHROMATOGRAPHY AND A SPECTROPHOTOMETRIC METHOD FOR DETERMINATION OF NITRATES IN MEAT-PRODUCTS
    BIANCHI, E
    BRUSCHI, R
    DRAISCI, R
    LUCENTINI, L
    [J]. ZEITSCHRIFT FUR LEBENSMITTEL-UNTERSUCHUNG UND-FORSCHUNG, 1995, 200 (04): : 256 - 260
  • [4] CAMSI AY, 1988, ANALYST, V113, P81
  • [5] OXIDATION OF FORMIC-ACID AT NOBLE-METAL ELECTRODES .4. PLATINUM + PALLADIUM ALLOYS
    CAPON, A
    PARSONS, R
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1975, 65 (01): : 285 - 305
  • [6] Amperometric method for the determination of nitrate in water
    Carpenter, NG
    Pletcher, D
    [J]. ANALYTICA CHIMICA ACTA, 1995, 317 (1-3) : 287 - 293
  • [7] CASSENS RG, 1995, FOOD TECHNOL-CHICAGO, V49, P72
  • [8] Electropolymerization of pyrrole-2-carboxylic acid and 4,4′-dihydroxybenzophenone on platinum electrodes.: Applications to assemble novel glucose sensors
    Curulli, A
    Palleschi, G
    [J]. ELECTROANALYSIS, 1997, 9 (14) : 1107 - 1112
  • [9] THE DETERMINATION OF NITRATE AND NITRITE IN CURED MEAT BY HPLC/UV
    DENNIS, MJ
    KEY, PE
    PAPWORTH, T
    POINTER, M
    MASSEY, RC
    [J]. FOOD ADDITIVES AND CONTAMINANTS, 1990, 7 (04): : 455 - 461
  • [10] ELECTROCATALYTIC REDUCTION OF NITRITE AT AN [OS(BIPY)2(PVP)10CL]CL-MODIFIED ELECTRODE
    DOHERTY, AP
    VOS, JG
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1992, 88 (19): : 2903 - 2907