A novel nanospray capillary zone electrophoresis mass spectrometry interface

被引:0
|
作者
Hsieh, F
Baronas, E
Muir, C
Martin, SA
机构
[1] Millennium Pharmaceut Inc, Cambridge, MA 02139 USA
[2] PerSept Biosyst Inc, Framingham, MA 01701 USA
关键词
D O I
10.1002/(SICI)1097-0231(19990115)13:1<67::AID-RCM453>3.3.CO;2-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The high resolution of capillary zone electrophoresis/mass spectrometry (CZE/MS) offers a promising technique to characterize biomolecules in pharmaceutical and biotechnology industries. A novel capillary zone electrophoresis/electrospray ionization time-of-flight mass spectrometry (CZE/ESI-TOF MS) interface was designed in this study to successfully integrate ESI-TOFMS, nanospray, and CZE for biomolecular identification. The interface offers a novel way to take advantage of the high resolution separation achieved during CZE and the detection sensitivity of nanospray ESI-MS. The results showed mixtures of peptides were highly resolved within a few minutes (each CZE electropherogram of a peptide is 2-3 seconds). The novel CZE/ESI-TOFMS interface may simultaneously provide sensitivity, data acquisition speed, mass range, and mass resolution while maintaining resolution of the CZE separation. Copyright (C) 1999 John Wiley & Sons, Ltd.
引用
收藏
页码:67 / 72
页数:6
相关论文
共 50 条
  • [1] A sheath-flow nanospray interface for capillary electrophoresis/mass spectrometry
    Liu, CC
    Zhang, JZ
    Dovichi, NJ
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (02) : 187 - 192
  • [2] Differential detection of Rhizoma coptidis by capillary electrophoresis electrospray ionization mass spectrometry with a nanospray interface
    Liu, Jing-Xin
    Zhang, Yi-Wei
    Yuan, Fang
    Chen, Hong-Xu
    Zhang, Xin-Xiang
    ELECTROPHORESIS, 2014, 35 (21-22) : 3258 - 3263
  • [3] Characterization of a capillary zone electrophoresis electrospray-mass spectrometry interface
    Siethoff, C
    Nigge, W
    Linscheid, M
    ANALYTICAL CHEMISTRY, 1998, 70 (07) : 1357 - 1361
  • [4] Separation of nicotine metabolites by capillary zone electrophoresis and capillary zone electrophoresis/mass spectrometry
    Palmer, ME
    Smith, RF
    Chambers, K
    Tetler, LW
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (03) : 224 - 231
  • [5] Analysis of gangliosides by capillary zone electrophoresis and capillary zone electrophoresis electrospray mass spectrometry
    Ju, DD
    Lai, CC
    Her, GR
    JOURNAL OF CHROMATOGRAPHY A, 1997, 779 (1-2) : 195 - 203
  • [6] Stable, reproducible, and automated capillary zone electrophoresis-tandem mass spectrometry system with an electrokinetically pumped sheath-flow nanospray interface
    Zhu, Guije
    Sun, Liangliang
    Yan, Xiaojing
    Dovichi, Norman J.
    ANALYTICA CHIMICA ACTA, 2014, 810 : 94 - 98
  • [7] A novel sheathless and electrodeless microelectrospray interface for the on-line coupling of capillary zone electrophoresis to mass spectrometry
    Mazereeuw, M
    Hofte, AJP
    Tjaden, UR
    vanderGreef, J
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1997, 11 (09) : 981 - 986
  • [8] IMPROVED ELECTROSPRAY IONIZATION INTERFACE FOR CAPILLARY ZONE ELECTROPHORESIS - MASS-SPECTROMETRY
    SMITH, RD
    BARINAGA, CJ
    UDSETH, HR
    ANALYTICAL CHEMISTRY, 1988, 60 (18) : 1948 - 1952
  • [9] CAPILLARY ZONE ELECTROPHORESIS MASS-SPECTROMETRY USING AN ELECTROSPRAY IONIZATION INTERFACE
    SMITH, RD
    OLIVARES, JA
    NGUYEN, NT
    UDSETH, HR
    ANALYTICAL CHEMISTRY, 1988, 60 (05) : 436 - 441
  • [10] CAPILLARY ZONE ELECTROPHORESIS-MASS SPECTROMETRY
    OLIVARES, JA
    NGUYEN, NT
    SMITH, RD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 204 - ANYL