Investigation of hydrophilic interaction liquid chromatography coupled with charged aerosol detector for the analysis of tromethamine

被引:4
|
作者
Beck, Taslyne Imame Hassane [1 ]
Toussaint, Balthazar [1 ,2 ]
Surget, Estelle [1 ]
Herrenknecht, Christine [3 ]
Boudy, Vincent [1 ,2 ]
Jaccoulet, Emmanuel [1 ]
机构
[1] Agence Gen Equipements & Prod Sante, AP HP, Dept Rech & Dev Pharmaceut DRDP, Paris, France
[2] Univ Paris, CNRS, INSERM, Unite Technol Chim & Biol Sante,Fac Pharm, Paris, France
[3] Univ Nantes, Lab Mer, Sante MMS EA 2160, Mol, B-44322 Nantes, Belgium
关键词
Charged aerosol detector; HILIC stationary Phases; FIA; Validation; Tromethamine; STABILITY-INDICATING METHOD; REVERSED-PHASE; TRIS(HYDROXYMETHYL)AMINOMETHANE TROMETHAMINE; PHARMACEUTICAL ANALYSIS; PERFORMANCE; VALIDATION; RETENTION; HPLC; ION; IMPURITIES;
D O I
10.1016/j.talanta.2021.123050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tromethamine (TMM), often encountered in a final drug product, exhibits interesting chemical properties as a counter ion, buffer, or active ingredient. European and US pharmacopeias propose titration against hydrogen chloride for TMM assays. However, this method can be a hindrance when using drugs containing low concentrations of TMM in complex buffered formulations. Due to the lack of chromophores and the high hydrophilicity of TMM, we performed a simple and reliable hydrophilic interaction chromatography coupled with a charged aerosol detector (HILIC-CAD) separation approach as an alternative for TMM analysis. An amide stationary phase and a mobile phase consisting of a binary mixture of acetonitrile and 10 mM ammonium formate, pH 3 (80/20, V/V) were used. As the CAD response deeply depends on parameters such as stationary phases and pH buffer, we investigated their impact and explored the optimal signal conditions. Including TMM analogs such as tris (hydroxymethyl) nitromethane and 2-amino-2-ethyl-1,3-propanediol allowed us to select these parameters appropriately. The effects of the evaporation temperature, flow rate, and power function value (PFV) on the CAD signal response were also studied and optimized. The method was validated according to the ICH Q2 R1 guidelines. A linear response (mean R2 > 0.997) covering the range for low TMM concentrations (170-520 mu g/ mL) was achieved. Satisfactory intra-day and inter-day precisions were obtained with RSDs lower than 1.9% and 2.8%, respectively. The trueness ranged from 99.6% to 101.2%, and the LOD was found to be 1.1 mu g/mL. The HILIC-CAD method has been applied to a sterile TMM solution for injection.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] A charged aerosol detector/chemiluminescent nitrogen detector/liquid chromatography/mass spectrometry system for regular and fragment compound analysis in drug discovery
    Jiang, Yutao
    Hascall, Daniel
    Li, Delia
    Pease, Joseph H.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1411 : 63 - 68
  • [22] Determination of perfluorinated carboxylic acids in water using liquid chromatography coupled to a corona-charged aerosol detector
    Zhou, Qian
    Chen, Mantang
    Zhu, Lihua
    Tang, Heqing
    TALANTA, 2015, 136 : 35 - 41
  • [23] Evaluation of hydrophilic interaction liquid chromatography stationary phases for analysis of opium alkaloids
    Bagheri, Mohsen
    Taheri, Mohammadreza
    Farhadpour, Mohsen
    Rezadoost, Hassan
    Ghassempour, Alireza
    Aboul-Enein, Hassan Y.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1511 : 77 - 84
  • [24] A positively charged porous graphitic carbon stationary phase for hydrophilic interaction liquid chromatography
    Hou, Yanjie
    Zhang, Feifang
    Liu, Xuefang
    Ren, Yanjun
    Yang, Bingcheng
    TALANTA, 2017, 164 : 159 - 163
  • [25] Analysis of oligonucleotides by hydrophilic interaction liquid chromatography coupled to negative ion electrospray ionization mass spectrometry
    Gong, Lingzhi
    McCullagh, James S. O.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (32) : 5480 - 5486
  • [26] A review of polysorbate quantification and its degradation analysis by liquid chromatography coupled with charged aerosol detection
    Shi, Lei
    Shen, Guobin
    Chai, Ruiping
    Gamache, Paul H.
    Jin, Yan
    JOURNAL OF CHROMATOGRAPHY A, 2025, 1742
  • [27] Composition of structural carbohydrates in biomass: Precision of a liquid chromatography method using a neutral detergent extraction and a charged aerosol detector
    Godin, Bruno
    Agneessens, Richard
    Gerin, Patrick A.
    Delcarte, Jerome
    TALANTA, 2011, 85 (04) : 2014 - 2026
  • [28] Fumonisin Measurement from Maize Samples by High-Performance Liquid Chromatography Coupled with Corona Charged Aerosol Detector
    Szekeres, Andras
    Budai, Andrea
    Bencsik, Otto
    Nemeth, Laszlo
    Bartok, Tibor
    Szecsi, Arpad
    Mesterhazy, AKos
    Vagvoelgyi, Csaba
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2014, 52 (10) : 1181 - 1185
  • [29] Simultaneous quantitation of inorganic ions in oligonucleotides using mixed-mode liquid chromatography coupled with a charged aerosol detector
    Li, Jiangwei
    Stolee, Jessica A.
    Meda, Alvin
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 204
  • [30] Hydrophilic Interaction Liquid Chromatography and Per Aqueous Liquid Chromatography in Fungicides Analysis
    Noga, Sylwia
    Felinger, Attila
    Buszewski, Boguslaw
    JOURNAL OF AOAC INTERNATIONAL, 2012, 95 (05) : 1362 - 1370