Investigation of hydrophilic interaction liquid chromatography coupled with charged aerosol detector for the analysis of tromethamine

被引:4
|
作者
Beck, Taslyne Imame Hassane [1 ]
Toussaint, Balthazar [1 ,2 ]
Surget, Estelle [1 ]
Herrenknecht, Christine [3 ]
Boudy, Vincent [1 ,2 ]
Jaccoulet, Emmanuel [1 ]
机构
[1] Agence Gen Equipements & Prod Sante, AP HP, Dept Rech & Dev Pharmaceut DRDP, Paris, France
[2] Univ Paris, CNRS, INSERM, Unite Technol Chim & Biol Sante,Fac Pharm, Paris, France
[3] Univ Nantes, Lab Mer, Sante MMS EA 2160, Mol, B-44322 Nantes, Belgium
关键词
Charged aerosol detector; HILIC stationary Phases; FIA; Validation; Tromethamine; STABILITY-INDICATING METHOD; REVERSED-PHASE; TRIS(HYDROXYMETHYL)AMINOMETHANE TROMETHAMINE; PHARMACEUTICAL ANALYSIS; PERFORMANCE; VALIDATION; RETENTION; HPLC; ION; IMPURITIES;
D O I
10.1016/j.talanta.2021.123050
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Tromethamine (TMM), often encountered in a final drug product, exhibits interesting chemical properties as a counter ion, buffer, or active ingredient. European and US pharmacopeias propose titration against hydrogen chloride for TMM assays. However, this method can be a hindrance when using drugs containing low concentrations of TMM in complex buffered formulations. Due to the lack of chromophores and the high hydrophilicity of TMM, we performed a simple and reliable hydrophilic interaction chromatography coupled with a charged aerosol detector (HILIC-CAD) separation approach as an alternative for TMM analysis. An amide stationary phase and a mobile phase consisting of a binary mixture of acetonitrile and 10 mM ammonium formate, pH 3 (80/20, V/V) were used. As the CAD response deeply depends on parameters such as stationary phases and pH buffer, we investigated their impact and explored the optimal signal conditions. Including TMM analogs such as tris (hydroxymethyl) nitromethane and 2-amino-2-ethyl-1,3-propanediol allowed us to select these parameters appropriately. The effects of the evaporation temperature, flow rate, and power function value (PFV) on the CAD signal response were also studied and optimized. The method was validated according to the ICH Q2 R1 guidelines. A linear response (mean R2 > 0.997) covering the range for low TMM concentrations (170-520 mu g/ mL) was achieved. Satisfactory intra-day and inter-day precisions were obtained with RSDs lower than 1.9% and 2.8%, respectively. The trueness ranged from 99.6% to 101.2%, and the LOD was found to be 1.1 mu g/mL. The HILIC-CAD method has been applied to a sterile TMM solution for injection.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Exploration of the effects of chloride ions on the analysis of polar compounds at low concentrations by hydrophilic interaction liquid chromatography coupled to a charged aerosol detector: Application to tromethamine
    Toussaint, Balthazar
    Immame Hassane Beck, Taslyne
    Surget, Estelle
    Boudy, Vincent
    Jaccoulet, Emmanuel
    JOURNAL OF SEPARATION SCIENCE, 2023, 46 (06)
  • [2] Quantitative analysis of the impurities in Etimicin using hydrophilic interaction liquid chromatography coupled with charged aerosol detector
    Gao, Jiarui
    Wang, Quan
    Wei, Xinyi
    Zhu, Bingqi
    Wang, Jian
    Wang, Fan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 249
  • [3] Recent applications of the Charged Aerosol Detector for liquid chromatography in drug quality control
    Schilling, Klaus
    Holzgrabe, Ulrike
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1619
  • [4] Direct determination of amino acids by hydrophilic interaction liquid chromatography with charged aerosol detection
    Socia, Adam
    Foley, Joe P.
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1446 : 41 - 49
  • [5] Performance of ion pairing chromatography and hydrophilic interaction liquid chromatography coupled to charged aerosol detection for the analysis of underivatized amino acids
    Pawellek, Ruben
    Holzgrabe, Ulrike
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1659
  • [6] A sensitive non-derivatization method for apramycin and impurities analysis using hydrophilic interaction liquid chromatography and charged aerosol detection
    Long, Zhen
    Guo, Zhimou
    Liu, Xiaoda
    Zhang, Qi
    Liu, Xingguo
    Jin, Yan
    Liang, Lina
    Li, Huisu
    Wei, Jie
    Wu, Ningpeng
    TALANTA, 2016, 146 : 423 - 429
  • [7] Universal response method for accurate quantitative analysis of the impurities in quinolone antibiotics using liquid chromatography coupled with diode array detector and charged aerosol detector
    Gao, Jiarui
    Wang, Fan
    Zhu, Bingqi
    Li, Ping
    Wang, Zhijian
    Wang, Jian
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1710
  • [8] Investigation of the Retention Mechanism of Cephalosporins by Zwitterionic Hydrophilic Interaction Liquid Chromatography
    Panderi, Irene
    Malamos, Yannis
    Machairas, George
    Zaharaki, Sabina
    CHROMATOGRAPHIA, 2016, 79 (15-16) : 995 - 1002
  • [9] Performance of charged aerosol detection with hydrophilic interaction chromatography
    Russell, Joseph J.
    Heaton, James C.
    Underwood, Tim
    Boughtflower, Robert
    McCalley, David V.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1405 : 72 - 84
  • [10] Universal response method for the quantitative analysis of multi-components in josamycin and midecamycin using liquid chromatography coupled with charged aerosol detector
    Liu, Guijun
    Zhu, Bingqi
    Ren, Xiaojuan
    Wang, Jian
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 192