Commissioning of a mobetron electron linear accelerator

被引:0
|
作者
Woollard, J
Gao, M
Samsami, N
Kanellitsas, C
Gupta, N
机构
[1] Ohio State Univ, Div Radiat Oncol, James Canc Hosp, Columbus, OH 43210 USA
[2] Ohio State Univ, Div Radiat Oncol, Richard J Solove Res Inst, Columbus, OH 43210 USA
关键词
D O I
10.1118/1.1997866
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this paper is to describe the commissioning of our Mobetron electron linear accelerator and share the experience gained during the commissioning process. Method and Materials: The Mobetron is a relatively lightweight and mobile linear accelerator that has been developed for use in an operating room suite for delivering intra‐operative radiation therapy. This accelerator is capable of delivering a therapeutic beam of electrons with nominal energies of 4, 6, 9 or 12 MeV. The Mobetron comes with a variety of circular cones, ranging in field size from 3 to 10 cm diameter, in 0.5 cm increments, and 3 different angles, flat, 15 and 30 degrees. For each energy and cone, the percent depth dose (PDD), isodose distribution and output factor were measured. These measurements were performed in a water phantom. A dose per MU calibration was performed for each energy, using the 10 cm flat cone, according to the TG‐51 protocol. The stability of this output was monitored as a function of time. Finally, dose values were measured at various locations around the Mobetron during operation in order to determine shielding requirements and warm‐up procedures. Results: PDDs and isodose distributions for the various cone sizes, cone angles and beam energies are presented. Additionally, plots of output factors as a function of field size for the 3 different sets of cones and beam energies are provided. Lastly, the doses at different locations around the Mobetron are shown and the impacts of these doses on shielding and warm‐up procedures are discussed. Conclusions: The commissioning is complete. PDDs and isodose distributions measured for the Mobetron were similar to those measured for the linac used previously. Due to the machines' design, we found the output did vary with time, by as much as 3% over a period of about 10 days. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1992 / 1992
页数:1
相关论文
共 50 条
  • [31] Commissioning and Preliminary Experience With a New CT-integrated Linear Accelerator
    Yu, L.
    Zhao, J.
    Wang, J.
    Zhang, Z.
    Hu, W.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E329 - E330
  • [32] Clinical commissioning and use of the Novalis Tx linear accelerator for SRS and SBRT
    Kim, Jinkoo
    Wen, Ning
    Jin, Jian-Yue
    Walls, Nicole
    Kim, Sangroh
    Li, Haisen
    Ren, Lei
    Huang, Yimei
    Doemer, Anthony
    Faber, Kathleen
    Kunkel, Tina
    Balawi, Ahssan
    Garbarino, Kimberly
    Levin, Kenneth
    Patel, Samir
    Ajlouni, Munther
    Miller, Brett
    Nurushev, Teamor
    Huntzinger, Calvin
    Schulz, Raymond
    Chetty, Indrin J.
    Movsas, Benjamin
    Ryu, Samuel
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (03): : 124 - 151
  • [33] Cloud-Based Quality Assurance Application for Linear Accelerator Commissioning
    Rogers, J.
    MEDICAL PHYSICS, 2015, 42 (06) : 3374 - 3374
  • [34] Commissioning of Monaco Treatment Planning System On An Elekta VersaHD Linear Accelerator
    Narayanasamy, G.
    Bosse, C.
    Saenz, D.
    Cruz, W.
    Mavroidis, P.
    Papanikolaou, N.
    Stathakis, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3376 - 3376
  • [35] CLINICAL COMMISSIONING OF RAPIDARC TREATMENT TECHNIQUE IN VARIAN UNIQUE LINEAR ACCELERATOR
    Chan, S. K.
    Lee, K. Y.
    Cheung, M. L. M.
    Chau, M. C.
    Cheung, K. Y.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S173 - S173
  • [36] Results of beam parameter measurement of the ELBE electron accelerator after commissioning
    Teichert, J
    Büchner, A
    Evtushenko, P
    Gabriel, F
    Lehnert, U
    Michel, P
    Voigtländer, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 507 (1-2): : 354 - 356
  • [37] ON THE DESIGN OF A CAVITY OF A LINEAR ELECTRON ACCELERATOR
    AKELEY, ES
    PHYSICAL REVIEW, 1946, 69 (5-6): : 255 - 255
  • [38] ELECTROMAGNETIC LINEAR ELECTRON-ACCELERATOR
    VOMVORIDIS, JL
    SPRANGLE, P
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1981, 26 (02): : 164 - 164
  • [39] Controller of a Pulsed Linear Electron Accelerator
    Instrum Exp Tech, 1 (457):
  • [40] Commissioning scenario for L-band electron accelerator by PARMELA code
    Yang, H. R.
    Kim, S. H.
    Moon, S. I.
    Cho, M. H.
    Namkung, W.
    Oh, J. S.
    Son, Y. G.
    Jang, S. D.
    Kwon, S. J.
    Park, S. J.
    2007 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-11, 2007, : 2064 - +