Commissioning of a mobetron electron linear accelerator

被引:0
|
作者
Woollard, J
Gao, M
Samsami, N
Kanellitsas, C
Gupta, N
机构
[1] Ohio State Univ, Div Radiat Oncol, James Canc Hosp, Columbus, OH 43210 USA
[2] Ohio State Univ, Div Radiat Oncol, Richard J Solove Res Inst, Columbus, OH 43210 USA
关键词
D O I
10.1118/1.1997866
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this paper is to describe the commissioning of our Mobetron electron linear accelerator and share the experience gained during the commissioning process. Method and Materials: The Mobetron is a relatively lightweight and mobile linear accelerator that has been developed for use in an operating room suite for delivering intra‐operative radiation therapy. This accelerator is capable of delivering a therapeutic beam of electrons with nominal energies of 4, 6, 9 or 12 MeV. The Mobetron comes with a variety of circular cones, ranging in field size from 3 to 10 cm diameter, in 0.5 cm increments, and 3 different angles, flat, 15 and 30 degrees. For each energy and cone, the percent depth dose (PDD), isodose distribution and output factor were measured. These measurements were performed in a water phantom. A dose per MU calibration was performed for each energy, using the 10 cm flat cone, according to the TG‐51 protocol. The stability of this output was monitored as a function of time. Finally, dose values were measured at various locations around the Mobetron during operation in order to determine shielding requirements and warm‐up procedures. Results: PDDs and isodose distributions for the various cone sizes, cone angles and beam energies are presented. Additionally, plots of output factors as a function of field size for the 3 different sets of cones and beam energies are provided. Lastly, the doses at different locations around the Mobetron are shown and the impacts of these doses on shielding and warm‐up procedures are discussed. Conclusions: The commissioning is complete. PDDs and isodose distributions measured for the Mobetron were similar to those measured for the linac used previously. Due to the machines' design, we found the output did vary with time, by as much as 3% over a period of about 10 days. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1992 / 1992
页数:1
相关论文
共 50 条
  • [21] THE MICROWAVE LINEAR ELECTRON ACCELERATOR
    NEWBERY, GR
    BRITISH JOURNAL OF RADIOLOGY, 1949, 22 (260): : 473 - 486
  • [22] OPERATION OF A LINEAR ELECTRON ACCELERATOR
    BECKER, GE
    CASWELL, DA
    PHYSICAL REVIEW, 1949, 76 (04): : 587 - 587
  • [23] MICROBUNCHING IN A LINEAR ELECTRON ACCELERATOR
    OSTROVSK.EK
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1966, 11 (01): : 111 - +
  • [24] THE YALE LINEAR ELECTRON ACCELERATOR
    SCHULTZ, HL
    WADEY, WG
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1951, 22 (06): : 383 - 388
  • [25] THE MIT LINEAR ELECTRON ACCELERATOR
    DEMOS, PT
    KIP, AF
    SLATER, JC
    JOURNAL OF APPLIED PHYSICS, 1952, 23 (01) : 53 - 65
  • [26] THE YALE LINEAR ELECTRON ACCELERATOR
    SCHULTZ, HL
    WADEY, WG
    SCIENCE, 1951, 114 (2967) : 486 - 486
  • [27] LINEAR ACCELERATOR AS ELECTRON SOURCE IN ELECTRON MICROSCOPE
    ZHILEIKO, GI
    SOVIET PHYSICS TECHNICAL PHYSICS-USSR, 1965, 9 (12): : 1684 - +
  • [28] Commissioning, clinical implementation, and performance of the Mobetron 2000 for intraoperative radiation therapy
    Wootton, Landon S.
    Meyer, Juergen
    Kim, Edward
    Phillips, Mark
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (01): : 230 - 242
  • [29] Final commissioning of the superconducting heavy ion linear accelerator at IUAC, Delhi
    Datta, Tripti Sekhar
    Choudhury, Anup
    Chacko, Jacob
    Kar, Soumen
    Antony, Joby
    Babu, Suresh
    Kumar, Manoj
    Mathuria, D. S.
    Sahu, Santosh
    Kanjilal, Dinakar
    PROCEEDINGS OF THE 25TH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2014, 2015, 67 : 802 - 808
  • [30] Commissioning of the Varian TrueBeam linear accelerator: A multi-institutional study
    Glide-Hurst, C.
    Bellon, M.
    Foster, R.
    Altunbas, C.
    Speiser, M.
    Altman, M.
    Westerly, D.
    Wen, N.
    Zhao, B.
    Miften, M.
    Chetty, I. J.
    Solberg, T.
    MEDICAL PHYSICS, 2013, 40 (03)