Perimetry in Young and Neurologically Impaired Children The Behavioral Visual Field (BEFIE) Screening Test Revisited

被引:32
作者
Koenraads, Yvonne [1 ]
Braun, Kees P. J. [2 ]
van der Linden, Denise C. P. [1 ]
Imhof, Saskia M. [1 ]
Porro, Giorgio L. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Ophthalmol, NL-3508 GA Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Brain Ctr Rudolf Magnus, Dept Pediat Neurol, NL-3508 GA Utrecht, Netherlands
关键词
EXTENT; INFANTS; AGE; SENSITIVITY; MRI;
D O I
10.1001/jamaophthalmol.2014.5257
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
IMPORTANCE Visual field examination in young or neurologically impaired children is a challenge. As a result, the Behavioral Visual Field (BEFIE) Screening Test was developed in 1995. OBJECTIVES To evaluate the applicability of the BEFIE test in a large population of young or neurologically impaired children, its reliability and consistency of findings across time, and its potential diagnostic value compared with standard conventional perimetry. DESIGN, SETTING, AND PARTICIPANTS The BEFIE testswere performed at an academic tertiary center and measured the peripheral visual field extension in degrees by observing an individual's response to a stimulus on a graded arc that moved from the periphery to the center of the visual field along different meridians. Patient files from all children who underwent this test were retrospectively analyzed. In total, 1788 BEFIE tests were performed in 835 children (median age, 3.4 years). MAIN OUTCOMES AND MEASURES Reliability and results of all testswere longitudinally evaluated. The diagnostic value of the BEFIE test was assessed by comparing monocular BEFIE test results with those of standard conventional perimetry in children who underwent both. RESULTS Of 1788 tests, 74%(95% CI, 72%-76%) were considered reliable from the age of 4 months and older, with increasing success with higher ages; 56% reliable in children younger than 1 year; 71% reliable in children between 1 and 2 years; and more than 75% reliable in children 2 years and older (Spearman r = 0.506; P = .11). Peripheral visual field defects were found in 28%(95% CI, 25%-31%) of all first reliable tests. In 75% of children who underwent serial testing, results were consistent and there were good explanations in the case of discrepancies. Comparison of monocular BEFIE tests with standard conventional perimetry results in 147 eyes yielded a positive predictive value of 98%(95% CI, 94%-100%), negative predictive value of 66%(95% CI, 56%-75%), specificity of 98%(95% CI, 95%-100%), sensitivity of 60% (95% CI, 50%-71%), and superior sensitivity of 80% (95% CI, 70%-91%) when only absolute peripheral visual field defects at standard conventional perimetry were accounted for. CONCLUSIONS AND RELEVANCE These data suggest that the BEFIE test is a valuable tool to detect peripheral visual field defects when standard conventional perimetry cannot be performed in young or neurologically impaired children.
引用
收藏
页码:319 / 325
页数:7
相关论文
共 32 条
[1]   Development of grating acuity and contrast sensitivity in the central and peripheral visual field of the human infant [J].
Allen, D ;
Tyler, CW ;
Norcia, AM .
VISION RESEARCH, 1996, 36 (13) :1945-1953
[2]   A new perimeter using the preferential looking response to assess peripheral visual fields in young and developmentally delayed children [J].
Allen, Louise E. ;
Slater, Michael E. ;
Proffitt, Ruth V. ;
Quarton, Elizabeth ;
Pelah, Adar .
JOURNAL OF AAPOS, 2012, 16 (03) :261-265
[3]  
BECK RW, 1985, OPHTHALMOLOGY, V92, P77
[4]   The reliability of frequency-doubling perimetry in young children [J].
Blumenthal, EZ ;
Haddad, A ;
Horani, A ;
Anteby, I .
OPHTHALMOLOGY, 2004, 111 (03) :435-439
[5]   Blindsight in children: does it exist and can it be used to help the child? Observations on a case series [J].
Boyle, NJ ;
Jones, DH ;
Hamilton, R ;
Spowart, KM ;
Dutton, GN .
DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 2005, 47 (10) :699-702
[6]   Development of the functional visual field [J].
Clohessy, AB ;
Posner, MI ;
Rothbart, MK .
ACTA PSYCHOLOGICA, 2001, 106 (1-2) :51-68
[7]   Stimulus motion increases measured visual field extent in children 3.5 to 30 months of age [J].
Delaney, SM ;
Dobson, V ;
Harvey, EM ;
Mohan, KM ;
Weidenbacher, HJ ;
Leber, NR .
OPTOMETRY AND VISION SCIENCE, 2000, 77 (02) :82-89
[8]   Measured Visual Field Extent Varies With Peripheral Stimulus Flicker Rate in Very Young Children [J].
Delaney, Suzanne M. ;
Dobson, Velma ;
Mohan, Kathleen M. .
OPTOMETRY AND VISION SCIENCE, 2005, 82 (09) :800-806
[9]   Visual field extent in children 3.5-30 months of age tested with a double-arc LED perimeter [J].
Dobson, V ;
Brown, AM ;
Harvey, EM ;
Narter, DB .
VISION RESEARCH, 1998, 38 (18) :2743-2760
[10]   SITA visual field testing in children [J].
Donahue, SP ;
Porter, A .
JOURNAL OF AAPOS, 2001, 5 (02) :114-117