Medical image restoration of dynamic lungs using optical transfer function of lung motion

被引:3
作者
Arbel, D [1 ]
Hadar, O
Kopeika, NS
机构
[1] Ben Gurion Univ Negev, Elect & Comp Engn Dept, IL-84105 Beer Sheva, Israel
[2] Ben Gurion Univ Negev, Commun Syst Engn Dept, IL-84105 Beer Sheva, Israel
关键词
lung motion; image motion; image vibration; image restoration; optical transfer function; medical imaging; isotrope imaging;
D O I
10.1117/1.1352749
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
When carrying out medical imaging based on detection of isotopic radiation levels of internal organs such a lungs or heart, distortions, and blur arise as a result of the organ motion during breathing and blood supply. Consequently, image quality declines, despite the use of expensive high resolution devices and, such devices are not exploited fully. A method with which to overcome the problem is image restoration. Previously, we suggested and developed a method for calculating numerically the optical transfer function (OTF) for any type of image motion. The purpose of this research is restoration of original isotope images (of the lungs) by restoration methods that depend on the OTF of the real time relative motion between the object and the imaging system. This research uses different algorithms for the restoration of an image, according to the OTF of the lung motion, which is in several directions simultaneously. One way of handling the three-dimensional movement is to decompose the image into several portions, to restore each portion according to its motion characteristics, and then to combine all the image portions back into a single image. An additional complication is that the image was recorded at different angles. The application of this research is In medical systems requiring high resolution imaging. The main advantage of this approach is its low cost versus conventional approaches. (C) 2001 society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:193 / 199
页数:7
相关论文
共 17 条
[1]  
BALFOUR NS, 1987, RESP PHYSL, P65
[2]  
COTES JE, 1979, LUNG FUNCTION ASSESS, P345
[3]   ROBUST IDENTIFICATION OF MOTION AND OUT-OF-FOCUS BLUR PARAMETERS FROM BLURRED AND NOISY IMAGES [J].
FABIAN, R ;
MALAH, D .
CVGIP-GRAPHICAL MODELS AND IMAGE PROCESSING, 1991, 53 (05) :403-412
[4]   IMAGE-RESOLUTION LIMITS RESULTING FROM MECHANICAL VIBRATIONS .4. REAL-TIME NUMERICAL-CALCULATION OF OPTICAL TRANSFER-FUNCTIONS AND EXPERIMENTAL-VERIFICATION [J].
HADAR, O ;
DROR, I ;
KOPEIKA, NS .
OPTICAL ENGINEERING, 1994, 33 (02) :566-578
[5]   IMAGE-RESOLUTION LIMITS RESULTING FROM MECHANICAL VIBRATIONS .3. NUMERICAL-CALCULATION OF MODULATION TRANSFER-FUNCTION [J].
HADAR, O ;
FISHER, M ;
KOPEIKA, NS .
OPTICAL ENGINEERING, 1992, 31 (03) :581-589
[6]  
Kopeika N.S., 1998, A system engineering approach to imaging
[7]  
RICHARDS CW, 1990, P 9 INT FLUID POW S, P315
[8]  
RICHARDS CW, 1990, P 9 INT C FLUID POW, P25
[9]   Restoration and resolution enhancement of a single image from a vibration-distorted image sequence [J].
Stern, A ;
Kempner, E ;
Shukrun, A ;
Kopeika, NS .
OPTICAL ENGINEERING, 2000, 39 (09) :2451-2457
[10]   General restoration filter for vibrated-image restoration [J].
Stern, A ;
Kopeika, NS .
APPLIED OPTICS, 1998, 37 (32) :7596-7603