Visual Function after Implantation of a Presbyopia-Correcting Trifocal Intraocular Lens

被引:22
作者
Alfonso, Jose F. [1 ,2 ]
Fernandez-Vega-Cueto, Luis [1 ]
Fernandez-Vega, Luis [1 ,2 ]
Montes-Mico, Robert [3 ]
机构
[1] Fernandez Vega Ophthalmol Inst, Ave Doctores Fernandez Vega 34, ES-33012 Oviedo, Spain
[2] Univ Oviedo, Dept Surg, Fac Med, Oviedo, Spain
[3] Univ Valencia, Opt & Optometry & Vis Sci Dept, Fac Phys, Valencia, Spain
关键词
Implantation; Visual function; Trifocal intraocular lens; OPTICAL BENCH PERFORMANCE; POWER CALCULATION FORMULAS; BILATERAL IMPLANTATION; PATIENT SATISFACTION; CONTRAST SENSITIVITY; BLENDED IMPLANTATION; CLINICAL-OUTCOMES; CATARACT-SURGERY; EXTENDED RANGE; DEFOCUS CURVES;
D O I
10.1159/000500834
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate distance, intermediate, and near visual performance in patients implanted with a trifocal aspheric presbyopia-correcting intraocular lens (IOL). Methods: Forty patients were bilaterally implanted with the AcrySofIQ PanOptix IOL after femtosecond laser-assisted lens surgery. Binocular best corrected distance visual acuity (CDVA) (4 m), best distance-corrected near visual acuity (DCNVA) (40 and 30 cm), best corrected distance intermediate visual acuity (DCIVA) (70, 60, and 50 cm), binocular distance contrast sensitivity under photopic conditions (85 cd/m(2)), and defocus curves were evaluated at 6-months. Results: Six months postoperatively, the mean binocular Snellen decimal CDVA and DCNVA were 0.94 +/- 0.10 (ranging from 0.70 to 1.25) and 0.85 +/- 0.13 (ranging from 0.63 to 1.00), respectively. At a distance, all patients showed a cumulative binocular distance-corrected visual acuity of 0.8 or better, and about 80% (n = 31) of the patients had a value of 1.0 (20/20). At near and intermediate distances, all patients showed a cumulative distance-corrected visual acuity of 0.5 (20/40) or better at 30, 40, 50, 60, and 70 cm. Specifically, 50 cm showed the highest percentage of patients with larger values of visual acuity (60% [n = 26] with 20/20). Defocus curve showed a wide range of useful vision with two peaks of best visual acuity at distance and at 50 cm, and the binocular distance contrast sensitivity was within normal limits. Conclusions: The outcomes of the present study show that the visual performance obtained with bilateral implantation of the trifocal aspheric AcrySofIQ PanOptix IOL is good at far, intermediate, and near distances.
引用
收藏
页码:152 / 164
页数:13
相关论文
共 61 条
  • [11] Cardona Genis, 2016, J Optom, V9, P78, DOI 10.1016/j.optom.2015.06.005
  • [12] Accuracy of the Refractive Prediction Determined by Multiple Currently Available Intraocular Lens Power Calculation Formulas in Small Eyes
    Carifi, Gianluca
    Aiello, Francesco
    Zygoura, Vasiliki
    Kopsachilis, Nikolaos
    Maurino, Vincenzo
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (03) : 577 - 583
  • [13] Optical bench performance of 3 trifocal intraocular lenses
    Carson, Daniel
    Xu, Zaiwei
    Alexander, Elsinore
    Choi, Myoung
    Zhao, Zeyu
    Hong, Xin
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (09) : 1361 - 1367
  • [14] Prospective Clinical Comparison of Patient Outcomes Following Implantation of Trifocal or Bifocal Intraocular Lenses
    Cochener, Beatrice
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (03) : 146 - +
  • [15] Clinical Outcomes With a Trifocal Intraocular Lens: A Multicenter Study
    Cochener, Beatrice
    Vryghem, Jerome
    Rozot, Pascal
    Lesieur, Gilles
    Chevalier, Jean-Paul
    Henry, Jean-Marie
    David, Thierry
    Lesueur, Laurence
    Gatinel, Damien
    Ganem, Cati
    Blanckaert, Johan
    Van Acker, Emmanuel
    Heireman, Steven
    Ghekiere, Sofie
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (11) : 762 - 768
  • [16] Visual and refractive outcomes after implantation of a fully diffractive trifocal lens
    Cochener, Beatrice
    Vryghem, Jerome
    Rozot, Pascal
    Lesieur, Gilles
    Heireman, Steven
    Blanckaert, Johan A.
    Van Acker, Emmanuel
    Ghekiere, Sofie
    [J]. CLINICAL OPHTHALMOLOGY, 2012, 6 : 1421 - 1427
  • [17] de Medeiros AL, 2017, CLIN OPHTHALMOL, V11, P1911, DOI 10.2147/OPTH.S145945
  • [18] Multifocal versus monofocal intraocular lenses after cataract extraction
    de Silva, Samantha R.
    Evans, Jennifer R.
    Kirthi, Varo
    Ziaei, Mohammed
    Leyland, Martin
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2016, (12):
  • [19] Multifocal intraocular lenses in cataract surgery: Literature review of benefits and side effects
    de Vries, Niels E.
    Nuijts, Rudy M. M. A.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (02) : 268 - 278
  • [20] Objective and subjective results following implantation of the FineVision trifocal intraocular lens in Mexican patients
    Ferreira-Rios, Ivo
    Zuniga-Posselt, Karla
    Carlos Serna-Ojeda, Juan
    Chavez-Mondragon, Eduardo
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (06) : 2617 - 2622