Algorithm Optimization for Quantitative Analysis of Intravascular Optical Coherence Tomography Data

被引:2
|
作者
van Soest, Gijs [1 ]
Goderie, Thade P. M. [1 ]
van Noorden, Sander [1 ]
van der Steen, Anton F. W. [1 ]
机构
[1] Erasmus MC, Ctr Thorax, NL-3000 CA Rotterdam, Netherlands
来源
PHOTONIC THERAPEUTICS AND DIAGNOSTICS V | 2009年 / 7161卷
关键词
OCT; atherosclerosis; optical attenuation; simulation; algorithm optimization; CORONARY ATHEROSCLEROTIC PLAQUES; VULNERABLE PLAQUE; IN-VIVO; SCATTERING MEDIA; ATTENUATION COEFFICIENTS; ULTRASOUND; ELASTOGRAPHY; ANGIOSCOPY; RUPTURE; CULPRIT;
D O I
10.1117/12.807344
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Optical Coherence Tomography (OCT) is rapidly becoming the method of choice for assessing arterial wall pathology in vivo. Atherosclerotic plaques can be diagnosed with high accuracy, including measurement of the thickness of fibrous caps, permitting an assessment of the risk of rupture. While the OCT image presents morphological information in highly resolved detail, it relies on interpretation of the images by trained readers for the identification of vessel wall components and tissue type. We developed a framework to aid the recognition of these atherosclerotic plaque constituents, based on the optical attenuation coefficient of the tissue. Based on a single-scattering model and using the point spread functions of individually characterized imaging catheters, several parameters need to be set in the analysis that may influence the results. Here, we present a simulation study used to optimize these parameters.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Validating Intravascular Imaging with Serial Optical Coherence Tomography and Confocal Fluorescence Microscopy
    Tardif, Pier-Luc
    Bertrand, Marie-Jeanne
    Abran, Maxime
    Castonguay, Alexandre
    Lefebvre, Joel
    Stahli, Barbara E.
    Merlet, Nolwenn
    Mihalache-Avram, Teodora
    Geoffroy, Pascale
    Mecteau, Melanie
    Busseuil, David
    Ni, Feng
    Abulrob, Abedelnasser
    Rheaume, Eric
    L'Allier, Philippe
    Tardif, Jean-Claude
    Lesage, Frederic
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2016, 17 (12):
  • [32] Quantitative assessment of skin swelling using optical coherence tomography
    Li, Weijun
    Li, Peng
    Fang, Yuhong
    Lei, Tim C.
    Dong, Kui
    Zou, Jian
    Gong, Wei
    Xie, Shusen
    Huang, Zheng
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2019, 26 : 413 - 419
  • [33] Quantitative Ex Vivo and In Vivo Comparison of Lumen Dimensions Measured by Optical Coherence Tomography and Intravascular Ultrasound in Human Coronary Arteries
    Gonzalo, Nieves
    Serruys, Patrick W.
    Garcia-Garcia, Hector M.
    van Soest, Gijs
    Okamura, Takayuki
    Ligthart, Jurgen
    Knaapen, Michiel
    Verheye, Stefan
    Bruining, Nico
    Regar, Evelyn
    REVISTA ESPANOLA DE CARDIOLOGIA, 2009, 62 (06): : 615 - 624
  • [34] Automated analysis of fibrous cap in intravascular optical coherence tomography images of coronary arteries
    Lee, Juhwan
    Pereira, Gabriel T. R.
    Gharaibeh, Yazan
    Kolluru, Chaitanya
    Zimin, Vladislav N.
    Dallan, Luis A. P.
    Kim, Justin N.
    Hoori, Ammar
    Al-Kindi, Sadeer G.
    Guagliumi, Giulio
    Bezerra, Hiram G.
    Wilson, David L.
    SCIENTIFIC REPORTS, 2022, 12 (01):
  • [35] The Role of Intravascular Optical Coherence Tomography in Peripheral Percutaneous Interventions
    Negi, Smita I.
    Rosales, Oscar
    JOURNAL OF INVASIVE CARDIOLOGY, 2013, 25 (03) : E51 - E53
  • [36] Optical Coherence Tomography: Its Value in Intravascular Diagnosis Today
    Herrero-Garibi, Jesus
    Cruz-Gonzalez, Ignacio
    Parejo-Diaz, Patricia
    Jang, Ik-Kyung
    REVISTA ESPANOLA DE CARDIOLOGIA, 2010, 63 (08): : 951 - 962
  • [37] Investigations of the intravascular backscattering distribution of light in optical coherence tomography
    Cimalla, Peter
    Walther, Julia
    Koch, Edmund
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554
  • [38] Analysis and compensation for the effect of the catheter position on image intensities in intravascular optical coherence tomography
    Liu, Shengnan
    Eggermont, Jeroen
    Wolterbeek, Ron
    Broersen, Alexander
    Busk, Carol A. G. R.
    Precht, Helle
    Lelieveldt, Boudewijn P. F.
    Dijkstra, Jouke
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (12)
  • [39] All-optical dual photoacoustic and optical coherence tomography intravascular probe
    Mathews, Sunish J.
    Little, Callum
    Loder, Christopher D.
    Rakhit, Roby D.
    Xia, Wenfeng
    Zhang, Edward Z.
    Beard, Paul C.
    Finlay, Malcolm C.
    Desjardins, Adrien E.
    PHOTOACOUSTICS, 2018, 11 : 65 - 70
  • [40] Combined optical coherence tomography and intravascular ultrasound radio frequency data analysis for plaque characterization. Classification accuracy of human coronary plaques in vitro
    T. P. M. Goderie
    G. van Soest
    H. M. Garcia-Garcia
    N. Gonzalo
    S. Koljenović
    G. J. L. H. van Leenders
    F. Mastik
    E. Regar
    J. W. Oosterhuis
    P. W. Serruys
    A. F. W. van der Steen
    The International Journal of Cardiovascular Imaging, 2010, 26 : 843 - 850