Energy efficiency improvement of electrical sterilization using oscillatory waveforms from a RLC discharging circuit

被引:5
作者
Lee, HK [1 ]
Suehiro, J
Hara, M
Lee, DC
So, MH
机构
[1] Bucheon Coll, Dept Elect Engn, Bucheon, South Korea
[2] Kyushu Univ, Grad Sch Informat Sci & Elect Engn, Dept Elect & Elect Syst Engn, Fukuoka 812, Japan
[3] Inha Univ, Dept Elect Engn, Inchon, South Korea
[4] Bucheon Coll, Dept Food Engn, Bucheon, South Korea
关键词
D O I
10.1109/94.892003
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes effects of pulsed Hv waveforms on biological cell inactivation. A simple RLC circuit with various inductance values was employed to investigate the waveform effects on the electrical sterilization of Escherichia Coli. It has been found that the minimum value of cell survivability can be realized by choosing an appropriate inductance value, even when the initial energy stored in a capacitor is constant. In order to realize the higher energy efficiency than a conventional RC discharging network, circuit parameters should be determined so that amplitude and width of each pulse become larger than the critical values 15 kV/cm and 50 mus, respectively.