High-resolution LC/MS for analysis of minor components in complex mixtures: negative ion ESI for identification of impurities and degradation products of a novel oligosaccharide antibiotic

被引:0
作者
Shipkova, PA
Heimark, L
Bartner, PL
Chen, GD
Pramanik, BN
Ganguly, AK
Cody, RB
Kusai, A
机构
[1] Schering Plough Res Inst, Kenilworth, NJ 07033 USA
[2] JEOL USA, Peabody, MA 01960 USA
来源
JOURNAL OF MASS SPECTROMETRY | 2000年 / 35卷 / 11期
关键词
high-resolution; electrospray; negative ion; everninomicin;
D O I
10.1002/1096-9888(200011)35:11<1252::AID-JMS56>3.0.CO;2-J
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
High-resolution mass spectrometry has been routinely used for structural confirmation and identification; however, it has mostly been applied to relatively pure samples. Exact mass measurement of minor components such as impurities, degradation products or metabolites in complex mixtures has been difficult without prior separation and isolation, Here we report the utilization of on-line liquid chromatography in combination with high-resolution mass spectrometry for the identification of impurities and base degradation products of Sch 27899, a member of the everninomicin class of antibiotics. Nine Sch 27899-related impurities and degradation products were detected by negative ion electrospray ionization using a magnetic sector mass spectrometer, Exact mass measurements were obtained at a resolution of 5000 using polyethylene glycol (PEG) sulfates as internal standards. Corresponding elemental compositions were determined within a 2 ppm error tolerance and structures were proposed for all components. Copyright (C) 2000 John Wiley & Sons, Ltd.
引用
收藏
页码:1252 / 1258
页数:7
相关论文
共 41 条
[1]  
Bahr U, 1999, RAPID COMMUN MASS SP, V13, P1052, DOI 10.1002/(SICI)1097-0231(19990615)13:11<1052::AID-RCM604>3.3.CO
[2]  
2-P
[3]   Structure elucidation of Everninomicin-6, a new oligosaccharide antibiotic, by chemical degradation and FAB-MS methods [J].
Bartner, P ;
Pramanik, BN ;
Saksena, AK ;
Liu, YH ;
Das, PR ;
Sarre, O ;
Ganguly, AK .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (11) :1134-1140
[4]   IMPROVED FOURIER-TRANSFORM ION-CYCLOTRON-RESONANCE MASS-SPECTROMETRY OF LARGE BIOMOLECULES [J].
BEU, SC ;
SENKO, MW ;
QUINN, JP ;
MCLAFFERTY, FW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (02) :190-192
[5]  
CHAPMAN JR, 1986, PRACTICAL ORGANIC MA
[6]   ELECTROSPRAY IONIZATION MAGNETIC-SECTOR MASS-SPECTROMETRY - CALIBRATION, RESOLUTION, AND ACCURATE MASS MEASUREMENTS [J].
CODY, RB ;
TAMURA, J ;
MUSSELMAN, BD .
ANALYTICAL CHEMISTRY, 1992, 64 (14) :1561-1570
[8]   Liquid chromatographic high-resolution mass spectrometric and tandem mass spectrometric identification of synthetic peptides, using electrospray ionization [J].
D'Agostino, PA ;
Hancock, JR ;
Provost, LR ;
Semchuk, PD ;
Hodges, RS .
JOURNAL OF CHROMATOGRAPHY A, 1998, 800 (01) :89-100
[9]   Analysis of bioactive peptides by liquid chromatography high-resolution electrospray mass spectrometry [J].
DAgostino, PA ;
Hancock, JR ;
Provost, LR .
JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) :77-85
[10]   HIGH-RESOLUTION ELECTROSPRAY MASS-SPECTROMETRY WITH A MAGNETIC-SECTOR INSTRUMENT - ACCURATE MASS MEASUREMENT AND PEPTIDE SEQUENCING [J].
DAGOSTINO, PA ;
HANCOCK, JR ;
PROVOST, LR ;
SEMCHUK, PD ;
HODGES, RS .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (07) :597-603