A novel reusable ionic liquid chemically bonded fused-silica fiber for headspace solid-phase microextraction/gas chromatography-flame ionization detection of methyl tert-butyl ether in a gasoline sample

被引:57
作者
Amini, Ramin [2 ]
Rouhollahi, Ahmad [1 ,2 ]
Adibi, Mina [3 ]
Mehdinia, Ali [4 ]
机构
[1] York Univ, Dept Chem, Toronto, ON M3J 1P3, Canada
[2] KN Toosi Univ Technol, Dept Chem, Fac Sci, Tehran, Iran
[3] Res Inst Petr Ind, Dept Specialty Chem, Div Chem & Petr Chem, Tehran, Iran
[4] Iranian Natl Ctr Oceanog, Dept Marine Living Resources, Tehran, Iran
关键词
Ionic liquid; Chemically bonding; Solid-phase microextraction; Methyl tert-butyl ether; Gasoline sample; Gas chromatography; GLASSY-CARBON FILMS; ORGANOCHLORINE PESTICIDES; STATIONARY PHASES; MASS-SPECTROMETRY; SORBENT COATINGS; SENSITIVE METHOD; WATER SAMPLES; AMYL ETHER; EXTRACTION; MTBE;
D O I
10.1016/j.chroma.2010.10.114
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel ionic liquid (IL) bonded fused-sil-ica fiber for headspace solid-phase microextraction (HS-SPME)/gas chromatography-flame ionization detection (GC-FID) of methyl tert-butyl ether (MTBE) in a gasoline sample was prepared and used. The new proposed chemically bonded fiber has better thermal stability and durability than its corresponding physically coated fiber. Another advantage is that no spacer was used for the purpose of bonding the IL to the surface of the fused-silica. The latter advantage makes the preparation of these fibers easier with lower cost than those prepared using sol-gel method. The ionic liquid 1-methyl-3-(3-trimethoxysilyl propyl) imidazolium bis(trifluoromethylsulfonyl) imide was synthesized and cross linked to the surface of the fused-silica fiber. Then, the chemically IL-modified fibers were applied to the headspace extraction of MTBE. The chemically IL-modified fibers showed improved thermal stability at temperatures up to 220 degrees C relative to the physically IL-modified fibers (180 degrees C). The chemically bonded IL film on the surface of the fused-silica fiber was durable over 16 headspace extractions without any significant loss of the IL film. The calibration graph was linear in a concentration range of 2-240 mu g L-1 (R-2 = 0.996) with the detection limit of 0.1 mu g L-1 level. The reproducibility (RSD %, n = 6) of the new IL bonded fused-silica fiber (8.9%) was better than the physically coated fiber (12%) suggesting that the proposed chemically IL-modified fiber is more robust than the physically IL-modified fiber. The optimum extraction conditions were the followings: 40 degrees C extraction temperature, 12 min extraction time, 30s desorption time and sample agitation at 200 rpm. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:130 / 136
页数:7
相关论文
共 75 条
[41]   Effect of residual chlorine on the analysis of geosmin, 2-MIB and MTBE in drinking water using the SPME technique [J].
Lin, TF ;
Liu, CL ;
Yang, FC ;
Hung, HW .
WATER RESEARCH, 2003, 37 (01) :21-26
[42]   Disposable ionic liquid coating for headspace solid-phase microextraction of benzene, toluene, ethylbenzene. and xylenes in paints followed by gas chromatography-flame ionization detection [J].
Liu, JF ;
Li, N ;
Jiang, GB ;
Li, JM ;
Jönsson, JÅ ;
Wen, MJ .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1066 (1-2) :27-32
[43]   Physically incorporated extraction phase of solid-phase microextraction by sol-gel technology [J].
Liu, WM ;
Hu, YA ;
Zhao, JH ;
Xu, YA ;
Guan, YF .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1102 (1-2) :37-43
[44]   Preparation and characterization of polydimethylsiloxatie/poly(vinylalcohol) coated solid phase microextraction fibers using sol-gel technology [J].
Lopes, AL ;
Augusto, F .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1056 (1-2) :13-19
[45]   Determination of water pollutants by direct-immersion solid-phase microextraction using polymeric ionic liquid coatings [J].
Lopez-Darias, Jessica ;
Pino, Veronica ;
Anderson, Jared L. ;
Graham, Christa M. ;
Afonso, Ana M. .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (08) :1236-1243
[46]   Nano-structured lead dioxide as a novel stationary phase for solid-phase microextraction [J].
Mehdinia, Ali ;
Mousavi, Mir Fazllolah ;
Shamsipur, Mojtaba .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1134 (1-2) :24-31
[47]   Exploiting the Versatility of Ionic Liquids in Separation Science: Determination of Low-Volatility Aliphatic Hydrocarbons and Fatty Acid Methyl Esters Using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography [J].
Meng, Yunjing ;
Pino, Veronica ;
Anderson, Jared L. .
ANALYTICAL CHEMISTRY, 2009, 81 (16) :7107-7112
[48]   Method detection limit determination and application of a convenient headspace analysis method for methyl tert-butyl ether in water [J].
O'Neill, DT ;
Rochette, EA ;
Ramsey, PJ .
ANALYTICAL CHEMISTRY, 2002, 74 (22) :5907-5911
[49]   SPME in environmental analysis [J].
Ouyang, Gangfeng ;
Pawliszyn, Janusz .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (04) :1059-1073
[50]   Determination of methyl tert-butyl ether in gasoline:: a comparison of three fast methods based on mass spectrometry [J].
Pavón, JLP ;
Sánchez, MD ;
Pinto, CG ;
Laespada, MEF ;
Cordero, BM .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1048 (01) :133-139