Platform with biomimetic electrochemical sensors for adiponectin and leptin detection in human serum

被引:23
作者
Mihailescu, Carmen Marinela [1 ,2 ]
Stan, Dana [3 ]
Savin, Mihaela [1 ,4 ]
Moldovan, Carmen Aura [1 ]
Dinulescu, Silviu [1 ]
Radulescu, Clara Hortensia [1 ]
Firtat, Bogdan [1 ]
Muscalu, George [1 ]
Brasoveanu, Costin [1 ]
Ion, Marian [1 ]
Dragomir, David [1 ,5 ]
Stan, Diana [3 ]
Ion, Alina Catrinel [4 ]
机构
[1] Natl Inst Res & Dev Microtechnol, Erou Iancu Nicolae St, Bucharest 077190, Romania
[2] Titu Maiorescu Univ, Pharmaceut Univ, Sincai St, Bucharest 040314, Romania
[3] DDS Diagnost, Vulcan Judetu St, Bucharest 031427, Romania
[4] Univ Politehn Bucuresti, Fac Appl Chem & Mat Sci, 1-7 Gheorghe Polizu St,Sect 1, Bucharest 011061, Romania
[5] Univ Politehn Bucuresti, Splaiul Independentel St 313, Bucharest 060042, Romania
关键词
Polyphenol; Molecularly imprinted polymers; Polyscopoletin; Metabolic syndrome; Conductance; Impedance; MOLECULARLY IMPRINTED POLYMER; METABOLIC SYNDROME; INSULIN-RESISTANCE; ATHEROSCLEROSIS; ASSOCIATION; DISEASE; RISK;
D O I
10.1016/j.talanta.2019.120643
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two new biomimetic sensors for the detection of adiponectin (A) and leptin (L) through molecularly imprinted polymers (MIPs) onto gold working electrodes (GWEs) were fabricated. Based on electrochemical impedance spectroscopy (EIS) results and cyclic voltammetry (CV) characteristics recorded in the development stages of the fabricated sensors, the sensors were electrochemically optimized and used in an integrated microfluidic platform to detect adiponectin/leptin via conductance signals and non-imprinted electrodes were used as references. To overcome the limitation of the low response signals after template binding non-conductive polyphenol (PP) and poliscopoletin (PS) were used for templates formation. Under optimized experimental conditions the conductance and resistance signals were obtained in the linear range of 0-50 mu g ml(-1) for A and 1-32 ng.ml-1 for L with low limits of detection (0.25 mu g ml(-1) for A and 0.110 ng ml(-1) for L). The dedicated platform exhibited an excellent response with great selectivity and stability. Finally, the proposed biomimetic sensors were successfully applied to enable the determination of A and L in human patient's serum with very high accuracy when compared to enzyme-linked immunosorbent assay ELISA reference methods.
引用
收藏
页数:8
相关论文
共 29 条
[1]   Association between Metabolic Syndrome and Carotid Atherosclerosis: Relevance of Combined Criteria Including the Serum Adiponectin Level for the General Population [J].
Abiko, Akihiko ;
Makita, Shinji ;
Naganuma, Yujirou ;
Nagai, Mizuyoshi ;
Nakamura, Motoyuki .
INTERNAL MEDICINE, 2011, 50 (05) :381-387
[2]   Harmonizing the Metabolic Syndrome A Joint Interim Statement of the International Diabetes Federation Task Force on Epidemiology and Prevention; National Heart, Lung, and Blood Institute; American Heart Association; World Heart Federation; International Atherosclerosis Society; and International Association for the Study of Obesity [J].
Alberti, K. G. M. M. ;
Eckel, Robert H. ;
Grundy, Scott M. ;
Zimmet, Paul Z. ;
Cleeman, James I. ;
Donato, Karen A. ;
Fruchart, Jean-Charles ;
James, W. Philip T. ;
Loria, Catherine M. ;
Smith, Sidney C., Jr. .
CIRCULATION, 2009, 120 (16) :1640-1645
[3]  
Leite KCD, 2015, INT J ELECTROCHEM SC, V10, P5714
[4]   Protein Rebinding to a Surface-Confined Imprint [J].
Dechtrirat, Decha ;
Jetzschmann, Katharina J. ;
Stoecklein, Walter F. M. ;
Scheller, Frieder W. ;
Gajovic-Eichelmann, Nenad .
ADVANCED FUNCTIONAL MATERIALS, 2012, 22 (24) :5231-5237
[5]   A selective molecularly imprinted polymer for immobilization of acetylcholinesterase (AChE): an active enzyme targeted and efficient method [J].
Demirci, Gokhan ;
Dogac, Yasemin Ispirli ;
Teke, Mustafa .
JOURNAL OF MOLECULAR RECOGNITION, 2015, 28 (11) :645-650
[6]   A turn-on type stimuli-responsive fluorescent dye with specific solvent effect: Implication for a new prototype of paper using water as the ink [J].
Hu, Xiaochen ;
Liu, Yang ;
Duan, Yuai ;
Han, Jingqi ;
Li, Zhongfeng ;
Han, Tianyu .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2017, 184 :7-12
[7]   Molecular imprinting of peptides and proteins in aqueous media [J].
Janiak, Daniel S. ;
Kofinas, Peter .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (02) :399-404
[8]   Association of Circulating Levels of Leptin and Adiponectin With Metabolic Syndrome and Coronary Heart Disease in Patients With Various Coronary Risk Factors [J].
Kajikawa, Yutaka ;
Ikeda, Masae ;
Takemoto, Shunji ;
Tomoda, Jun ;
Ohmaru, Natsuki ;
Kusachi, Shozo .
INTERNATIONAL HEART JOURNAL, 2011, 52 (01) :17-22
[9]   Serum leptin is associated with cardiometabolic risk and predicts metabolic syndrome in Taiwanese adults [J].
Li, Wen-Cheng ;
Hsiao, Kuang-Yu ;
Chen, I-Chuan ;
Chang, Yu-Che ;
Wang, Shih-Hao ;
Wu, Kuan-Han .
CARDIOVASCULAR DIABETOLOGY, 2011, 10
[10]   A robust electrochemical sensing of molecularly imprinted polymer prepared by using bifunctional monomer and its application in detection of cypermethrin [J].
Li, Yangguang ;
Zhang, Lu ;
Dang, Yanyan ;
Chen, Zongqin ;
Zhang, Ruyue ;
Li, Yingchun ;
Ye, Bang-Ce .
BIOSENSORS & BIOELECTRONICS, 2019, 127 :207-214