A method to predict patient-specific table coordinates for quality assurance in external beam radiation therapy

被引:3
作者
Saenz, Daniel L. [1 ]
Astorga, Nestor Rodrigo [1 ]
Kirby, Neil [1 ]
Fakhreddine, Mohamad [1 ]
Rasmussen, Karl [1 ]
Stathakis, Sotirios [1 ]
Papanikolaou, Niko [1 ]
机构
[1] Univ Texas Hlth San Antonio, San Antonio, TX 78229 USA
关键词
external beam radiotherapy; patient safety; quality assurance; SETUP;
D O I
10.1002/acm2.12428
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: While external beam radiotherapy treatment planning determines nearly every mechanical and dosimetric parameter of the linear accelerator (LINAC), the table coordinates in all three dimensions are generally unknown until initial patient setup at the LINAC. Knowing these parameters in advance could help verify the direction of patient shifts and prevent wrong-site errors. This study aims to determine the feasibility and accuracy of table coordinate prediction for indexed immobilization devices. Methods: A total of 303 table coordinates were predicted for patients on Varian and Elekta linear accelerators with immobilization devices including Orfit mask with baseplate, wingboard, breastboard and BodyFix. Predictions were made for all three spatial dimensions except for Body Fix setups due to the lack of a radiographically apparent indexing-related landmark. Coordinates were predicted by measuring baseline table coordinates in all dimensions at specified landmark positions. Results: Predictions were accurate within 2 cm for 86% of coordinates (71% within 1 cm). Table coordinates were predicted most accurately for head and neck patients with a base plate and the most difficult prediction was in the lateral direction for breastboard patients. Conclusions: With proper indexing, table coordinates can be predicted with reasonable accuracy. The data suggest an action of level of 2 cm with certain exceptions for specific immobilization devices and directions.
引用
收藏
页码:625 / 631
页数:7
相关论文
共 13 条
[1]  
[Anonymous], PHYS MED BIOL
[2]   A survey on table tolerances and couch overrides in radiotherapy [J].
Chinsky, Bonnie ;
Patel, Rakesh ;
Panfil, Joshua ;
Surucu, Murat ;
Roeske, John C. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06) :405-420
[3]   A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload [J].
De Boer, HCJ ;
Heijmen, BJM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (05) :1350-1365
[4]  
Ezzell G, 2018, PRAC RAD ONC, VS1879-8500, P30318
[5]   Data Driven Approaches for Determination of Treatment Table Tolerance Values for Record and Verification Systems [J].
Gupta, N. ;
DiCostanzo, D. ;
Fullenkamp, M. .
MEDICAL PHYSICS, 2015, 42 (06) :3572-3573
[6]   Analysis of couch position tolerance limits to detect mistakes in patient setup [J].
Hadley, Scott W. ;
Balter, James M. ;
Lam, Kwok L. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2009, 10 (04) :207-219
[7]   Errors in radiation oncology: A study in pathways and dosimetric impact [J].
Klein, Eric E. ;
Drzymala, Robert E. ;
Purdy, James A. ;
Michalski, Jeff .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2005, 6 (03) :81-94
[8]   Site-specific tolerance tables and indexing device to improve patient setup reproducibility [J].
McCullough, Kiernan T. ;
James, Joshua A. ;
Cetnar, Ashley J. ;
McCullough, Mark A. ;
Wang, Brian .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03) :378-388
[9]   Effectiveness of couch coordinate constraints to reduce error rates in radiation therapy delivery [J].
Nairz, O. ;
Breitkreutz, N. .
RADIOTHERAPY AND ONCOLOGY, 2017, 123 :S564-S565
[10]  
Pennsylvania Patient Safety Authority, 2009, THERAPY, V6, P87