Diagnostic accuracy of CBCT compared to panoramic radiography in predicting IAN exposure: a systematic review and meta-analysis

被引:25
作者
Brito Reia, Veronica Caroline [1 ]
Telles-Araujo, Gabriel de Toledo [2 ]
Peralta-Mamani, Mariela [1 ]
Biancardi, Mariel Ruivo [1 ]
Fischer Rubira, Cassia Maria [1 ]
Fischer Rubira-Bullen, Izabel Regina [1 ]
机构
[1] Univ Sao Paulo, Bauru Sch Dent, Dept Surg Stomatol Pathol & Radiol, Alameda Octavio Pinheiro Brisola 9-75, BR-17012901 Bauru, SP, Brazil
[2] Univ Fed Bahia, Sch Med, Salvador, BA, Brazil
关键词
Third molars; Cone beam computed tomography; Mandibular canal; Lower alveolar nerve; Mandibular nerve injuries; MANDIBULAR 3RD MOLAR; BEAM COMPUTED-TOMOGRAPHY; INFERIOR ALVEOLAR NERVE; TOPOGRAPHIC RELATIONSHIP; REMOVAL; INJURY; RISK; SURGERY; IMAGES; ROOT;
D O I
10.1007/s00784-021-03942-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The aim of this study is to verify whether the diagnostic accuracy of cone beam computed tomography (CBCT) is superior to panoramic radiography (PR) in predicting inferior alveolar nerve (IAN) exposure during the lower third molar extraction. Materials and methods Eight electronic databases were searched up to September 2020. Studies that evaluated the accuracy (sensitivity, specificity, positive-predictive value, and negative predictive value) of both imaging methods were included. The gold standard was the visualization of the IAN exposure during the extraction of lower third molars. The gray literature was also used to include any other paper that might meet the eligibility criteria. The meta-analysis was performed with OpenMeta-Analyst and ReviewManager v.5.3 software. The methodology of the studies was evaluated using QUADAS-2. Results Among the search, three studies met all the eligibility criteria and were included in the qualitative and quantitative synthesis. The meta-analysis was conducted with all included studies. Accuracy values for CBCT were 95.1% for sensitivity (p=0.666) and 64.4% for specificity (p<0.001). For PR sensitivity and specificity, we observed 73.9% (p=0.101) and 24.8% (p<0.001), respectively. Conclusions Both exams were reliable for detecting positive cases of exposure of the IAN. However, CBCT had a better performance compared to PT in predicting IAN exposure during surgery.
引用
收藏
页码:4721 / 4733
页数:13
相关论文
共 50 条
[31]   Diagnostic accuracy of telemedicine for detection of surgical site infection: a systematic review and meta-analysis [J].
Lathan, Ross ;
Sidapra, Misha ;
Yiasemidou, Marina ;
Long, Judith ;
Totty, Joshua ;
Smith, George ;
Chetter, Ian .
NPJ DIGITAL MEDICINE, 2022, 5 (01)
[32]   Diagnostic accuracy of physical examination findings for midfacial fractures: a systematic review and meta-analysis [J].
Rozema, Romke ;
Doff, Michiel H. J. ;
Delli, Konstantina ;
Spijkervet, Frederik K. L. ;
van Minnen, Baucke .
CLINICAL ORAL INVESTIGATIONS, 2022, 26 (04) :3405-3427
[33]   The Delirium Observation Screening Scale: A Systematic Review and Meta-Analysis of Diagnostic Test Accuracy [J].
Park, Jinkyung ;
Jeong, Eunhye ;
Lee, Juneyoung .
CLINICAL NURSING RESEARCH, 2021, 30 (04) :464-473
[34]   Diagnostic accuracy of carotid plaque instability by noninvasive imaging: a systematic review and meta-analysis [J].
Pakizer, David ;
Kozel, Jiri ;
Taffe, Patrick ;
Elmers, Jolanda ;
Feber, Janusz ;
Michel, Patrik ;
Skoloudik, David ;
Sirimarco, Gaia .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (10) :1325-1335
[35]   A Systematic Review and Meta-analysis of the Diagnostic Accuracy of Frozen Section for Parotid Gland Lesions [J].
Schmidt, Robert L. ;
Hunt, Jason P. ;
Hall, Brian J. ;
Wilson, Andrew R. ;
Layfield, Lester J. .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2011, 136 (05) :729-738
[36]   Accuracy of infrared thermography for perforator mapping: A systematic review and meta-analysis of diagnostic studies [J].
Berner, Juan Enrique ;
Pereira, Nicolas ;
Troisi, Luigi ;
Will, Patrick ;
Nanchahal, Jagdeep ;
Jain, Abhilash .
JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2021, 74 (06) :1173-1179
[37]   The diagnostic accuracy of artificial intelligence in thoracic diseases: A protocol for systematic review and meta-analysis [J].
Yang, Yi ;
Jin, Gang ;
Pang, Yao ;
Wang, Wenhao ;
Zhang, Hongyi ;
Tuo, Guangxin ;
Wu, Peng ;
Wang, Zequan ;
Zhu, Zijiang .
MEDICINE, 2020, 99 (07)
[38]   Diagnostic accuracy of cone-beam breast computed tomography: a systematic review and diagnostic meta-analysis [J].
Johannes Uhlig ;
Annemarie Uhlig ;
Lorenz Biggemann ;
Uwe Fischer ;
Joachim Lotz ;
Susanne Wienbeck .
European Radiology, 2019, 29 :1194-1202
[39]   Diagnostic accuracy of cone-beam breast computed tomography: a systematic review and diagnostic meta-analysis [J].
Uhlig, Johannes ;
Uhlig, Annemarie ;
Biggemann, Lorenz ;
Fischer, Uwe ;
Lotz, Joachim ;
Wienbeck, Susanne .
EUROPEAN RADIOLOGY, 2019, 29 (03) :1194-1202
[40]   Diagnostic performance of deep learning models in classifying mandibular third molar and mandibular canal contact status on panoramic radiographs: A systematic review and meta-analysis [J].
Al Salieti, Hamza ;
Al Sliti, Hala ;
Alkadi, Saleh .
IMAGING SCIENCE IN DENTISTRY, 2025,