Diagnostic accuracy of CBCT compared to panoramic radiography in predicting IAN exposure: a systematic review and meta-analysis

被引:22
|
作者
Brito Reia, Veronica Caroline [1 ]
Telles-Araujo, Gabriel de Toledo [2 ]
Peralta-Mamani, Mariela [1 ]
Biancardi, Mariel Ruivo [1 ]
Fischer Rubira, Cassia Maria [1 ]
Fischer Rubira-Bullen, Izabel Regina [1 ]
机构
[1] Univ Sao Paulo, Bauru Sch Dent, Dept Surg Stomatol Pathol & Radiol, Alameda Octavio Pinheiro Brisola 9-75, BR-17012901 Bauru, SP, Brazil
[2] Univ Fed Bahia, Sch Med, Salvador, BA, Brazil
关键词
Third molars; Cone beam computed tomography; Mandibular canal; Lower alveolar nerve; Mandibular nerve injuries; MANDIBULAR 3RD MOLAR; BEAM COMPUTED-TOMOGRAPHY; INFERIOR ALVEOLAR NERVE; TOPOGRAPHIC RELATIONSHIP; REMOVAL; INJURY; RISK; SURGERY; IMAGES; ROOT;
D O I
10.1007/s00784-021-03942-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The aim of this study is to verify whether the diagnostic accuracy of cone beam computed tomography (CBCT) is superior to panoramic radiography (PR) in predicting inferior alveolar nerve (IAN) exposure during the lower third molar extraction. Materials and methods Eight electronic databases were searched up to September 2020. Studies that evaluated the accuracy (sensitivity, specificity, positive-predictive value, and negative predictive value) of both imaging methods were included. The gold standard was the visualization of the IAN exposure during the extraction of lower third molars. The gray literature was also used to include any other paper that might meet the eligibility criteria. The meta-analysis was performed with OpenMeta-Analyst and ReviewManager v.5.3 software. The methodology of the studies was evaluated using QUADAS-2. Results Among the search, three studies met all the eligibility criteria and were included in the qualitative and quantitative synthesis. The meta-analysis was conducted with all included studies. Accuracy values for CBCT were 95.1% for sensitivity (p=0.666) and 64.4% for specificity (p<0.001). For PR sensitivity and specificity, we observed 73.9% (p=0.101) and 24.8% (p<0.001), respectively. Conclusions Both exams were reliable for detecting positive cases of exposure of the IAN. However, CBCT had a better performance compared to PT in predicting IAN exposure during surgery.
引用
收藏
页码:4721 / 4733
页数:13
相关论文
共 50 条
  • [21] Accuracy of SelectMDx compared to mpMRI in the diagnosis of prostate cancer: a systematic review and diagnostic meta-analysis
    Reza Sari Motlagh
    Takafumi Yanagisawa
    Tatsushi Kawada
    Ekaterina Laukhtina
    Pawel Rajwa
    Abdulmajeed Aydh
    Frederik König
    Maximilan Pallauf
    Nicolai A. Huebner
    Pascal A. Baltzer
    Pierre I. Karakiewicz
    Axel Heidenreich
    Shahrokh F. Shariat
    Prostate Cancer and Prostatic Diseases, 2022, 25 : 187 - 198
  • [22] Diagnostic accuracy of cervical elastography in predicting labor induction success: a systematic review and meta-analysis
    Londero, Ambrogio P.
    Schmitz, Ralf
    Bertozzi, Serena
    Driul, Lorenza
    Fruscalzo, Arrigo
    JOURNAL OF PERINATAL MEDICINE, 2016, 44 (02) : 167 - 178
  • [23] Diagnostic test accuracy: methods for systematic review and meta-analysis
    Campbell, Jared M.
    Klugar, Miloslav
    Ding, Sandrine
    Carmody, Dennis P.
    Hakonsen, Sasja J.
    Jadotte, Yuri T.
    White, Sarahlouise
    Munn, Zachary
    INTERNATIONAL JOURNAL OF EVIDENCE-BASED HEALTHCARE, 2015, 13 (03) : 154 - 162
  • [24] Diagnostic Accuracy of the ID Migraine: A Systematic Review and Meta-Analysis
    Cousins, Grainne
    Hijazze, Samira
    Van de Laar, Floris A.
    Fahey, Tom
    HEADACHE, 2011, 51 (07): : 1140 - 1148
  • [25] The diagnostic accuracy of procalcitonin for bacteraemia: a systematic review and meta-analysis
    Hoeboer, S. H.
    van der Geest, P. J.
    Nieboer, D.
    Groeneveld, A. B. J.
    CLINICAL MICROBIOLOGY AND INFECTION, 2015, 21 (05) : 474 - 481
  • [26] Accuracy of chest radiography compared to ultrasound for positioning the umbilical venous catheter in neonates: A meta-analysis and systematic review
    Cao, Juan
    Zhang, Yuzheng
    Yin, Yanling
    Liu, Yuxiu
    JOURNAL OF VASCULAR ACCESS, 2023, 24 (05): : 1051 - 1060
  • [27] Diagnostic accuracy of tests for leprosy: a systematic review and meta-analysis
    Gurung, P.
    Gomes, C. M.
    Vernal, S.
    Leeflang, M. M. G.
    CLINICAL MICROBIOLOGY AND INFECTION, 2019, 25 (11) : 1315 - 1327
  • [28] Diagnostic accuracy for skin cancers: a systematic review and meta-analysis
    Chen, Jennifer
    Fernandez, Kristen
    Reddy, Rasika
    Fadadu, Raj
    Kohn, Michael
    Kim, Mi-Ok
    Wei, Maria
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2023, 89 (03) : AB148 - AB148
  • [29] Anatomical variations of mandibular canal detected by panoramic radiography and CT: a systematic review and meta-analysis
    Haas, Leticia F.
    Dutra, Kamile
    Porporatti, Andre Luis
    Mezzomo, Luis A.
    Canto, Graziela De Luca
    Flores-Mir, Carlos
    Correa, Marcio
    DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (02)
  • [30] Diagnostic accuracy of preoperative ultrasonography in predicting contralateral inguinal hernia in children: a systematic review and meta-analysis
    K. M. A. Dreuning
    C. E. M. ten Broeke
    J. W. R. Twisk
    S. G. F. Robben
    R. R. van Rijn
    J. I. M. L. Verbeke
    L. W. E. van Heurn
    J. P. M. Derikx
    European Radiology, 2019, 29 : 866 - 876