摘要
We developed a label-free impedance biosensor based on an innovative conductive linker for detecting antibody-antigen interactions. As the often used conventional long chain thiol is a poor conductor, it is not a suitable material for use in a faradaic biosensor. In this study, we adopted a thiophene-based conductive bio-linker to form a self-assembled monolayer and to immobilize the bio-molecules. We used cyclic voltammetry and impedance spectroscopy to verify the enhanced conductivity properties. Results showed that the electron transfer resistance of this new conductive linker was 3 orders of a magnitude lower than for a case using a conventional long chain thiol linker. With the decreased impedance (i.e. increased faradaic current), we can obtain a higher signal/noise ratio such that the detection limit is improved. Using fluorescence microscopy, we verified that our new conductive linker has a protein immobilization capability similar to a conventional long chain thiol linker. Also, using S100 proteins, we verified the protein interaction detection capability of our system. Our obtained results showed a linear dynamic range from 10 ng/ml to 10 mu g/ml and a detection limit of 10 ng/ml. With our new conductive linker, an electrochemical impedance biosensor shows great potential to be used for point-of-care applications. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:3072 / 3076
页数:5
相关论文
共 43 条
[11]   A new quantitative optical biosensor for protein characterisation [J].
Cross, GH ;
Reeves, AA ;
Brand, S ;
Popplewell, JF ;
Peel, LL ;
Swann, MJ ;
Freeman, NJ .
BIOSENSORS & BIOELECTRONICS, 2003, 19 (04) :383-390
[12]   Layer-by-layer assembly of multilayer films composed of avidin and biotin-labeled antibody for immunosensing [J].
Cui, XQ ;
Pei, RJ ;
Wang, XZ ;
Yang, F ;
Ma, Y ;
Dong, SJ ;
Yang, XR .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (01) :59-67
[13]   Label-free impedance biosensors: Opportunities and challenges [J].
Daniels, Jonathan S. ;
Pourmand, Nader .
ELECTROANALYSIS, 2007, 19 (12) :1239-1257
[14]   Development of an immunosensor for the detection of vitellogenin using impedance spectroscopy [J].
Darain, F ;
Park, DS ;
Park, JS ;
Shim, YB .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (10) :1245-1252
[15]   Modified-RNA aptamer-based sensor for competitive impedimetric assay of neomycin B [J].
de-los-Santos-Alvarez, Noemi ;
Lobo-Castanon, Maria Jesus ;
Miranda-Ordieres, Arturo J. ;
Tunon-Blanco, Paulino .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2007, 129 (13) :3808-+
[16]   Electrochemical evaluation of avidin-biotin interaction on self-assembled gold electrodes [J].
Ding, SJ ;
Chang, BW ;
Wu, CC ;
Lai, MF ;
Chang, HC .
ELECTROCHIMICA ACTA, 2005, 50 (18) :3660-3666
[17]   Gold screen-printed-based impedimetric immunobiosensors for direct and sensitive Escherichia coli quantisation [J].
Escamilla-Gomez, Vanessa ;
Campuzano, Susana ;
Pedrero, Maria ;
Pingarron, Jose M. .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (11) :3365-3371
[18]   Electron permeable self-assembled monolayers of dithiolated aromatic scaffolds on gold for biosensor applications [J].
Fragoso, Alex ;
Laboria, Noemi ;
Latta, Daniel ;
O'Sullivan, Ciara K. .
ANALYTICAL CHEMISTRY, 2008, 80 (07) :2556-2563
[19]   Electrochemical biosensors -: Sensor principles and architectures [J].
Grieshaber, Dorothee ;
MacKenzie, Robert ;
Voeroes, Janos ;
Reimhult, Erik .
SENSORS, 2008, 8 (03) :1400-1458
[20]   Label free analysis of transcription factors using microcantilever arrays [J].
Huber, F ;
Hegner, M ;
Gerber, C ;
Güntherodt, HJ ;
Lang, HP .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (08) :1599-1605