Biomechanical rationale for implant choices in femoral neck fracture fixation in the non-elderly

被引:155
作者
Panteli, Michalis [1 ]
Rodham, Paul [2 ]
Giannoudis, Peter V. [1 ,2 ,3 ,4 ]
机构
[1] Univ Leeds, Sch Med, Acad Dept Trauma & Orthopaed, Leeds LS2 9JT, W Yorkshire, England
[2] Newcastle Univ, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
[3] Univ Leeds, LIMM Sect Musculoskeletal Dis, Leeds LS2 9JT, W Yorkshire, England
[4] Chapel Allerton Hosp, NIHR Leeds Biomed Res Unit, Leeds LS7 4SA, W Yorkshire, England
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2015年 / 46卷 / 03期
关键词
Femoral neck fracture; Biomechanics; Non-elderly; Young; INTRACAPSULAR HIP-FRACTURES; BONE-MINERAL DENSITY; INTERNAL-FIXATION; CANNULATED SCREW; PROXIMAL FEMUR; TRAUMA PATIENTS; WEIGHT-BEARING; YOUNG-ADULTS; EPIDEMIOLOGY; METAANALYSIS;
D O I
10.1016/j.injury.2014.12.031
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Femoral neck fractures represent a relatively uncommon injury in the non-elderly population often resulting from high-energy trauma. The cornerstone of their management is anatomic reduction and stable internal fixation of the femoral neck in an attempt to salvage the femoral head. Complications including avascular necrosis of the femoral head, non-union and post-traumatic osteoarthritis are not uncommon. The clinical outcomes of these patients can be improved with good pre-operative planning, optimization of surgical procedures and introduction of new improved implants and techniques. In the herein study, we attempt to describe the biomechanical properties of the hip and compare the performance of the most commonly used devices. Experimental evidence suggests that in Pauwels type III fracture patterns a cephalomedullary nail was significantly stronger in axial loading. Moreover, in unstable basicervical patterns cannulated screws (triangular configuration) demonstrated a lower ultimate load to failure, whereas in subcapital or transervical patterns both the cannulated screws (triangular configuration) and the sliding hip screw demonstrated no compromise in fixation strength. The fracture pattern appears to be the major determinant of the ideal type of implant to be selected. For a successful outcome each patient needs to be considered on an individual basis taking into account all patient and implant related factors. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:445 / 452
页数:8
相关论文
共 89 条
[1]   In vivo measurements show tensile axial strain in the proximal lateral aspect of the human femur [J].
Aamodt, A ;
Lund-Larsen, J ;
Eine, J ;
Andersen, E ;
Benum, P ;
Husby, OS .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (06) :927-931
[2]  
[Anonymous], 2006, FRACT NECK FEM FACTS
[4]   SUBCAPITAL FRACTURES OF FEMUR [J].
BARNES, R ;
BROWN, JT ;
GARDEN, RS ;
NICOLL, EA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1976, 58 (01) :2-24
[5]   Locking plates and their effects on healing conditions and stress distribution: A femoral neck fracture study in cadavers [J].
Basso, Trude ;
Klaksvik, Jomar ;
Foss, Olav A. .
CLINICAL BIOMECHANICS, 2014, 29 (05) :595-598
[6]   The effect of interlocking parallel screws in subcapital femoral-neck fracture fixation: a cadaver study [J].
Basso, Trude ;
Klaksvik, Jomar ;
Foss, Olav Andreas .
CLINICAL BIOMECHANICS, 2014, 29 (02) :213-217
[7]   Biomechanical femoral neck fracture experiments-A narrative review [J].
Basso, Trude ;
Klaksvik, Jomar ;
Syversen, Unni ;
Foss, Olav A. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2012, 43 (10) :1633-1639
[8]   Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[9]   The Biomechanical Significance of Washer Use With Screw Fixation [J].
Bishop, Julius A. ;
Behn, Anthony W. ;
Castillo, Tiffany N. .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (02) :114-117
[10]   Outcome of undisplaced and moderately displaced femoral neck fractures -: A prospective study of 466 patients treated by internal fixation [J].
Bjorgul, Kristian ;
Reikeras, Olav .
ACTA ORTHOPAEDICA, 2007, 78 (04) :498-504