Validity and Reliability of a Commercial Force Sensor for the Measurement of Upper Body Strength in Sport Climbing

被引:6
作者
Labott, Berit K. [1 ,2 ]
Held, Steffen [2 ]
Wiedenmann, Tim [2 ]
Rappelt, Ludwig [2 ]
Wicker, Pamela [3 ]
Donath, Lars [2 ]
机构
[1] Otto Von Guericke Univ, Inst Sport Sci, Magdeburg, Germany
[2] German Sport Univ Cologne, Dept Intervent Res Exercise Training, Cologne, Germany
[3] Bielefeld Univ, Dept Sports Sci, Bielefeld, Germany
来源
FRONTIERS IN SPORTS AND ACTIVE LIVING | 2022年 / 4卷
关键词
mountaineering; strength training; finger flexor muscles; performance; maximal strength; FLEXIBILITY CHARACTERISTICS; STATISTICAL-METHODS; FINGER ENDURANCE; ROCK CLIMBERS; ELITE; DETERMINANTS;
D O I
10.3389/fspor.2022.838358
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Recreational and professional climbing is gaining popularity. Thus, valid and reliable infield strength monitoring and testing devices are required. This study aims at assessing the validity as well as within- and between-day reliability of two climbing-specific hanging positions for assessing the maximum force with a new force measurement device. Therefore, 25 experienced male (n = 16) and female (n = 9) climbers (age: 25.5 +/- 4.2 years, height: 176.0 +/- 9.9 cm, weight: 69.7 +/- 14.5 kg, body composition: 11.8 +/- 5.7% body fat, climbing level: 17.5 +/- 3.9 International Rock Climbing Research Association scale) were randomly tested with climbing-specific hang board strength tests (one-handed rung pulling and one-handed bent arm lock-off at 90 degrees). The Tindeq, a load cell-based sensor for assessing different force-related variables, was employed together with a force plate (Kistler Quattro Jump) during both conditions. Data analysis revealed excellent validity for assessment with Tindeq: The intra-class correlation coefficient (ICC) was 0.99 (both positions), while the standard error of the measurement (SEM), coefficient of variation (CV), and limits of agreement (LoA) showed low values. Within day reliability for the assessment with Tindeq was excellent: rung pulling showed an ICC of 0.90 and arm lock-off an ICC of 0.98; between-day reliability was excellent as well: rung pulling indicated an ICC of 0.95 and arm lock-off an ICC of 0.98. Other reliability indicators such as SEM, CV, and LoA were low. The Tindeq progressor can be applied for the cross-sectional and longitudinal climbing strength assessment as this device can detect training-induced changes reliably.
引用
收藏
页数:9
相关论文
共 51 条
[1]  
[Anonymous], TINDEQ PROGR 0000
[2]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[3]  
Augste C., 2020, PERFORMANCE DIAGNOST
[4]  
Bal J., 2014, Sports Technol, V7, P151, DOI [https://doi.org/10.1080/19346182.2015.1012082, DOI 10.1080/19346182.2015.1012082, 10.1080/19346182.2015.1012082]
[5]   Isolated finger flexor vs. exhaustive whole-body climbing tests? How to assess endurance in sport climbers? [J].
Balas, Jiri ;
Gajdosik, Jan ;
Giles, David ;
Fryer, Simon ;
Krupkova, Dominika ;
Brtnik, Tomas ;
Feldmann, Andri .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2021, 121 (05) :1337-1348
[6]  
BILLAT V, 1995, J SPORT MED PHYS FIT, V35, P20
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]   Energy cost of sport rock climbing in elite performers [J].
Booth, J ;
Marino, F ;
Hill, C ;
Gwinn, T .
BRITISH JOURNAL OF SPORTS MEDICINE, 1999, 33 (01) :14-18
[9]  
Cohen Jacob, 1988, Statistical Power Anaylsis for the Behavior Sciences, V2nd, DOI [10.4324/9780203771587, DOI 10.4324/9780203771587]
[10]   Reliability of Force Application to Instrumented Climbing Holds In Elite Climbers [J].
Donath, Lars ;
Wolf, Peter .
JOURNAL OF APPLIED BIOMECHANICS, 2015, 31 (05) :377-382