An audit of laryngoscopes and application of a new ISO standard

被引:7
作者
Baker, Paul A. [1 ]
McQuoid, Shane [2 ]
Thompson, John M. D. [3 ]
Jacobs, Robert J. [4 ]
机构
[1] Starship Childrens Hlth, Dept Anaesthesia, Auckland 1050, New Zealand
[2] Middlemore Hosp, Auckland 6, New Zealand
[3] Univ Auckland, Dept Paediat, Auckland, New Zealand
[4] Univ Auckland, Dept Optometry & Vis Sci, Auckland 1, New Zealand
关键词
airway techniques; laryngoscopes; audit; LIGHT-INTENSITY; MANNEQUIN; BLADES; MINIMUM;
D O I
10.1111/j.1460-9592.2011.03525.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
P>Objective: The International Organization for Standardization (ISO) recently published an International Standard (ISO 7376:2009) which specifies illuminance levels and tests for illumination from hook-on type laryngoscopes used for intubation. A clinical study examining luminance for laryngoscopy found that 100 cd center dot m-2 was the minimum level acceptable for laryngoscopy. The purpose of this study was to measure the quality of light from laryngoscopes available for use by anesthetists in an anesthetic department and compare them to the ISO illuminance standard and published minimum acceptable luminance limits. Methods: A measuring device was constructed to support each laryngoscope in a standardized manner. For 190 reusable laryngoscopes, illuminance was measured with a lux meter at the base of this device. Eighteen clinically available laryngoscopes were then examined in detail, as a snapshot study, with multiple light recordings according to the ISO Standard. We also measured the luminance provided by each laryngoscope. Results: Only two of the 18 laryngoscopes met the minimum illuminance level of 500 lux after 10 min. Nine laryngoscopes provided a luminance < 100 cd center dot m-2, which is the reported minimum required luminance for laryngoscopy. None of the 18 laryngoscopes tested complied with the ISO standard for laryngoscope light distribution. Conclusions: Laryngoscope light should be regularly audited. Results from these audits can be used to retire or repair substandard laryngoscopes to maintain acceptable standards of laryngoscope light. Audit results produce tangible evidence that is useful when applying for capital expenditure. Light measurements are not easy to make. There needs to be a convenient device to reliably measure laryngoscope illumination.
引用
收藏
页码:428 / 434
页数:7
相关论文
共 13 条
  • [1] Brousseau P, 2004, CAN J ANESTH, V51, P47
  • [2] The effect of mechanical cleaning and thermal disinfection on light intensity provided by fibrelight Macintosh laryngoscopes
    Bucx, MJL
    de Gast, HM
    Veldhuis, J
    Hassing, LH
    Meulemans, A
    Kammeyer, A
    [J]. ANAESTHESIA, 2003, 58 (05) : 461 - 465
  • [3] An assessment of the luminance and light field characteristics of used direct laryngoscopes
    Crosby, E
    Cleland, M
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1999, 46 (08): : 792 - 796
  • [4] The reliability of laryngoscope lights
    Howes, BW
    [J]. ANAESTHESIA, 2006, 61 (05) : 488 - 491
  • [5] *INT ORG STAND, 73762009E ISO, P1
  • [6] Light intensity of curved laryngoscope blades in Philadelphia emergency departments
    Levitan, Richard M.
    Kelly, John J.
    Kinkle, William C.
    Fasano, Charles
    [J]. ANNALS OF EMERGENCY MEDICINE, 2007, 50 (03) : 253 - 257
  • [7] Minimum and optimum light requirements for laryngoscopy in paediatric anaesthesia: a manikin study
    Malan, C. A.
    Scholz, A.
    Wilkes, A. R.
    Hampson, M. A.
    Hall, J. E.
    [J]. ANAESTHESIA, 2008, 63 (01) : 65 - 70
  • [8] What is an unacceptable light level for direct laryngoscopy?
    Milne, Andrew D.
    Brousseau, Paul
    [J]. CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2009, 56 (09): : 711 - 711
  • [9] Laryngoscope illumination grade does not influence time to successful manikin intubation
    Moore, Simone
    Dwyer, Donovan
    Arendts, Glenn
    [J]. EMERGENCY MEDICINE AUSTRALASIA, 2009, 21 (02) : 131 - 135
  • [10] Changes in the light intensity of the fiberoptic laryngoscope blade by steam sterilization
    Nishiyama, Tomoki
    [J]. ANESTHESIA AND ANALGESIA, 2007, 104 (04) : 908 - 910