Final acceptance tests of helium refrigerator for Wendelstein 7-X
被引:4
|作者:
Dhard, C. P.
[1
]
Nagel, M.
[1
]
Raatz, S.
[1
]
Nuesslein, U.
[2
]
Ressel, M.
[2
]
机构:
[1] Max Planck Inst Plasma Phys, Teilinst Greifswald, Wendelsteinstr 1, D-17491 Greifswald, Germany
[2] Linde Kryotech AG, CH-8422 Pfungen, Switzerland
来源:
PROCEEDINGS OF THE 25TH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2014
|
2015年
/
67卷
关键词:
Helium refrigerator;
Wendelstein;
7-X;
Cryogenics for fusion;
Cold circulator;
Cold compressor;
D O I:
10.1016/j.phpro.2015.06.015
中图分类号:
O59 [应用物理学];
学科分类号:
摘要:
Following successful installation and commissioning, final acceptance tests were carried out on the helium refrigerator for Wendelstein 7-X. The tests were carried out for the normal operating modes i.e. peak power mode (3.4 K), standard mode (3.9 K), short standby mode (< 10 K) and long standby mode (< 100 K). Besides the normal modes, the transient modes including, cool-down and warm-up, auto interchanging between various modes and the purging modes were tested. In addition, the handling of quench, emergency signals such as cryostat vacuum break, utility failure, alarm and trip signals were checked. (C) 2015 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).