Improved quantification of coronary artery luminal stenosis in the presence of heavy calcifications using photon-counting detector CT

被引:24
作者
Koons, Emily [1 ]
VanMeter, Patrick [1 ]
Rajendran, Kishore [1 ]
Yu, Lifeng [1 ]
McCollough, Cynthia [1 ]
Leng, Shuai [1 ]
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
来源
MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING | 2022年 / 12031卷
基金
美国国家卫生研究院;
关键词
Coronary CT Angiography (cCTA); Coronary Artery Disease (CAD); Photon Counting Detector CT (PCD-CT); Calcifications; Stenosis; ANGIOGRAPHY;
D O I
10.1117/12.2613019
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Coronary CT Angiography (cCTA) is commonly used to detect and quantify luminal stenoses in patients with coronary artery disease (CAD). However, its use is limited in patients with heavy coronary calcifications due to calcium blooming, which is caused by insufficient spatial resolution. This study evaluated the ability of a photon-counting-detector (PCD) CT in quantifying luminal stenosis in the presence of heavy calcifications relative to an energy-integrating-detector (EID) CT. Cylindrical rods of 4.5 mm diameter (with 3 mm lumen), which contained calcium hydroxyapatite (CaHA) to emulate calcifications of varying shapes and sizes and an iodine or blood analog to emulate the coronary lumen, were placed within an anthropomorphic thorax phantom and scanned at matched dose on an EID-CT and a PCD-CT scanner. Stenoses were qualitatively evaluated and quantified using commercial software. Measured percent area stenosis was compared to reference values. PCD-CT provided better visualization of calcium plaques and the patent lumen, and more accurate stenosis quantification for all plaques. In one rod (75% occlusion with ring-shaped plaque), only PCD-CT was able to determine that the vessel was not fully obstructed. The phantom results indicate luminal stenoses that were previously considered non-assessable due to the presence of heavily-calcified plaques can be assessed using PCD-CT. Clinical studies to support these conclusions are underway.
引用
收藏
页数:5
相关论文
共 10 条
[1]   The challenge of coronary calcium on coronary computed tomographic angiography (CCTA) scans: effect on interpretation and possible solutions [J].
Andrew, Makmur ;
John, Hoe .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 :145-157
[2]  
C. f.D. Control, 2015, TABLE 19 LEADING CAU
[3]   The diagnostic accuracy of 256-row computed tomographic angiography compared with invasive coronary angiography in patients with suspected coronary artery disease [J].
Chao, Shu-Ping ;
Law, Wai-Yip ;
Kuo, Chu-Jen ;
Hung, Huei-Fong ;
Cheng, Jun-Jack ;
Lo, Huey-Ming ;
Shyu, Kou-Gi .
EUROPEAN HEART JOURNAL, 2010, 31 (15) :1916-1923
[4]   Photon-counting CT review [J].
Flohr, Thomas ;
Petersilka, Martin ;
Henning, Andre ;
Ulzheimer, Stefan ;
Ferda, Jiri ;
Schmidt, Bernhard .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 79 :126-136
[5]   Coronary CT Angiography versus Standard Evaluation in Acute Chest Pain [J].
Hoffmann, Udo ;
Truong, Quynh A. ;
Schoenfeld, David A. ;
Chou, Eric T. ;
Woodard, Pamela K. ;
Nagurney, John T. ;
Pope, J. Hector ;
Hauser, Thomas H. ;
White, Charles S. ;
Weiner, Scott G. ;
Kalanjian, Shant ;
Mullins, Michael E. ;
Mikati, Issam ;
Peacock, W. Frank ;
Zakroysky, Pearl ;
Hayden, Douglas ;
Goehler, Alexander ;
Lee, Hang ;
Gazelle, G. Scott ;
Wiviott, Stephen D. ;
Fleg, Jerome L. ;
Udelson, James E. .
NEW ENGLAND JOURNAL OF MEDICINE, 2012, 367 (04) :299-308
[6]   Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology [J].
Leng, Shuai ;
Bruesewitz, Michael ;
Tao, Shengzhen ;
Rajendran, Kishore ;
Halaweish, Ahmed F. ;
Campeau, Norbert G. ;
Fletcher, Joel G. ;
McCollough, Cynthia H. .
RADIOGRAPHICS, 2019, 39 (03) :729-743
[7]   Blooming Artifact Reduction in Coronary Artery Calcification by A New De-blooming Algorithm: Initial Study [J].
Li, Ping ;
Xu, Lei ;
Yang, Lin ;
Wang, Rui ;
Hsieh, Jiang ;
Sun, Zhonghua ;
Fan, Zhanming ;
Leipsic, Jonathon A. .
SCIENTIFIC REPORTS, 2018, 8
[8]   Comprehensive plaque assessment by coronary CT angiography [J].
Maurovich-Horvat, Pal ;
Ferencik, Maros ;
Voros, Szilard ;
Merkely, Bela ;
Hoffmann, Udo .
NATURE REVIEWS CARDIOLOGY, 2014, 11 (07) :390-402
[9]   Coronary CT angiography: current status and continuing challenges [J].
Sun, Z. ;
Choo, G. H. ;
Ng, K. H. .
BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1013) :495-510
[10]   Vision 20/20: Single photon counting x-ray detectors in medical imaging [J].
Taguchi, Katsuyuki ;
Iwanczyk, Jan S. .
MEDICAL PHYSICS, 2013, 40 (10) :100901