Effect of slice thickness and primary 2D versus 3D virtual dissection on colorectal lesion detection at CT Colonography in 452 asymptomatic adults

被引:38
作者
Johnson, C. Daniel
Fletcher, Joel G.
MacCarty, Robert L.
Mandrekar, Jay N.
Harmsen, William S.
Limburg, Paul J.
Wilson, Lynn A.
机构
[1] Mayo Clin, Dept Radiol, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Biostat, Rochester, MN 55905 USA
[3] Mayo Clin, Dept Gastroenterol, Rochester, MN 55905 USA
关键词
colonoscopy; colorectal cancer; CT colonography; oncologic imaging; virtual dissection display;
D O I
10.2214/AJR.07.2354
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to compare the performance of primary 3D search using 360 virtual dissection with primary 2D search using a 2.5- versus a 1.25-mm slice thickness. SUBJECTS AND METHODS. Four hundred fifty-two asymptomatic patients underwent CT colonography (CTC) and colonoscopy. Examinations were reconstructed to 1.25- and 2.5- mm slice thicknesses and interpreted using primary 3D search (360 virtual dissection) and primary 2D search. Two of three experienced reviewers were randomly assigned to each case; 1,808 interpretations were performed. RESULTS. There were 64 adenomas >= 6 mm, 26 of which were large adenomas >= 1 cm. For adenomas 6-9 mm in diameter, the area under the receiver operating characteristic curve (AUC) using 2.5-mm data sets was 0.66, 0.62, 0.90 and 0.78, 0.69, 0.67 for reviewers 1, 2, and 3, respectively, using primary 3D versus 2D search (p = not significant [NS]). For neoplasms = 10 mm, the AUC using 2.5- mm data sets was 0.74, 0.85, 0.89 and 0.66, 0.86, 0.92 for reviewers 1, 2, and 3 using primary 3D versus 2D search (p = NS). There was no significant difference using 1.25- mm collimation. Double review using both primary 3D and 2D search yielded sensitivities of 84% (16/19) and 95% (18/19) for large neoplasms (>= 1 cm) using 2.5- and 1.25mm data sets, respectively. Five of five (100%) adenocarcinomas were identified. The sensitivity of colonoscopy for large neoplasms was 77% (20/26) (20% [1/5] for adenocarcinoma). CONCLUSION. No advantage exists for 1.25- or 2.5- mm slice thickness or for primary 3D versus 2D search at CTC. Double review using primary 3D ( virtual dissection) and 2D search reduces interobserver variability and competes with colonoscopy for the detection of large lesions.
引用
收藏
页码:672 / 680
页数:9
相关论文
共 37 条
  • [1] Variability in the interpretation of screening mammograms by US radiologists - Findings from a national sample
    Beam, CA
    Layde, PM
    Sullivan, DC
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1996, 156 (02) : 209 - 213
  • [2] Nonradiologists as second readers for intraluminal findings at CT colonography
    Bodily, KD
    Fletcher, JG
    Engelby, T
    Percival, M
    Christensen, JA
    Young, B
    Krych, AJ
    Kooi, DCV
    Rodysill, D
    Fidler, JL
    Johnson, CD
    [J]. ACADEMIC RADIOLOGY, 2005, 12 (01) : 67 - 73
  • [3] Computed tomographic colonography (virtual colonoscopy) - A multicenter comparison with standard colonoscopy for detection of colorectal neoplasia
    Cotton, PB
    Durkalski, VL
    Benoit, PC
    Palesch, YY
    Mauldin, PD
    Hoffman, B
    Vining, DJ
    Small, WC
    Affronti, J
    Rex, D
    Kopecky, KK
    Ackerman, S
    Burdick, JS
    Brewington, C
    Turner, MA
    Zfass, A
    Wright, AR
    Iyer, RB
    Lynch, P
    Sivak, MV
    Butler, H
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 291 (14): : 1713 - 1719
  • [4] CT colonography with three-dimensional problem solving for detection of colonic polyps
    Dachman, AH
    Kuniyoshi, JK
    Boyle, CM
    Samara, Y
    Hoffmann, KR
    Rubin, DT
    Hanan, I
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (04) : 989 - 995
  • [5] Optimization of scanning parameters for multi-slice CT colonography: Experiments with synthetic and animal phantoms
    Embleton, KV
    Nicholson, DA
    Hufton, AP
    Jackson, A
    [J]. CLINICAL RADIOLOGY, 2003, 58 (12) : 955 - 963
  • [6] Comparative performance of two polyp detection systems on CT colonography
    Fletcher, J. G.
    Booya, Fargol
    Summers, Ronald M.
    Roy, David
    Guendel, Lutz
    Schmidt, Bernhard
    McCollough, Cynthia H.
    Fidler, Jeff L.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (02) : 277 - 282
  • [7] Fletcher JG, 2005, CURR OPIN GASTROEN, V21, P90
  • [8] Feasibility of planar virtual pathology: A new paradigm in volume-rendered CT colonography
    Fletcher, JG
    Johnson, CD
    Reed, JE
    Garry, J
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2001, 25 (06) : 864 - 869
  • [9] Optimization of CT colonography technique: Prospective trial in 180 patients
    Fletcher, JG
    Johnson, CD
    Welch, TJ
    MacCarty, RL
    Ahlquist, DA
    Reed, JE
    Harmsen, WS
    Wilson, LA
    [J]. RADIOLOGY, 2000, 216 (03) : 704 - 711
  • [10] Colorectal cancer screening with CT colonography, colonoscopy, and double-contrast barium enema examination: Prospective assessment of patient perceptions and preferences
    Gluecker, TM
    Johnson, CD
    Harmsen, WS
    Offord, KP
    Harris, AM
    Wilson, LA
    Ahlquist, DA
    [J]. RADIOLOGY, 2003, 227 (02) : 378 - 384