A Static Ground Power Unit Based on the Improved Hybrid Active Neutral-Point-Clamped Converter

被引:32
作者
Abarzadeh, Mostafa [1 ]
Kojabadi, Hossein Madadi [1 ]
机构
[1] Sahand Univ Technol, Renewable Energy & Adv Power Elect Res Ctr, Tabriz 5166733158, Iran
关键词
Active neutral-point-clamped (ANPC) converter; flying capacitor (FC) active balancing; inductance size reduction; power switch reduction; static ground power unit (GPU); MULTICELL CONVERTERS; MULTILEVEL; INVERTER; VOLTAGE; PHASE; MODULATION; FREQUENCY; BALANCE; PWM;
D O I
10.1109/TIE.2016.2557314
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper proposes a new configuration for static ground power unit (GPU) based on the novel 25-level hybrid active neutral-point-clamped (HANPC) converter. The superiority of the proposed converter, as compared with conventional and other suggested multilevel converters, is significant decreasing the number of switches and minimizing the number of flying capacitors (FC) in converter. This improvement is possible by using suggested low-voltage submodule converter to the ANPC converter and proposed modulation method. This results in reduction of the size and cost of converter and makes it more feasible and reliable. Applying the active voltage balancing method for FC in the proposed HANPC converter guaranties fast charging and voltage-level regulation of FC without using balance booster circuit. Improving output voltage spectrum leads to inductance reduction of output L-C filter which enhances static GPU performance. The simulation and experimental results verify the validity and feasibility of the proposed converter.
引用
收藏
页码:7792 / 7803
页数:12
相关论文
共 38 条
[1]  
Abarzadeh M, 2015, IEEE ENER CONV, P3508, DOI 10.1109/ECCE.2015.7310156
[2]  
[Anonymous], P EUR C POW EL APPL
[3]   Space Vector Modulation for Cascaded Asymmetrical Multilevel Converters Under Fault Conditions [J].
Carnielutti, Fernanda ;
Rech, Cassiano ;
Pinheiro, Humberto .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (01) :344-352
[4]   Flying Capacitors Reduction in an Improved Double Flying Capacitor Multicell Converter Controlled by a Modified Modulation Method [J].
Dargahi, Vahid ;
Sadigh, Arash Khoshkbar ;
Abarzadeh, Mostafa ;
Pahlavani, Mohammad Reza Alizadeh ;
Shoulaie, Abbas .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (09) :3875-3887
[5]   A Generic Open-Loop Algorithm for Three-Phase Grid Voltage/Current Synchronization With Particular Reference to Phase, Frequency, and Amplitude Estimation [J].
Freijedo, Francisco D. ;
Doval-Gandoy, Jesus ;
Lopez, Oscar ;
Acha, Enrique .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (1-2) :94-107
[6]   Multicell converters: Active control and observation of flying-capacitor voltages [J].
Gateau, G ;
Fadel, M ;
Maussion, P ;
Bensaid, R ;
Meynard, TA .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2002, 49 (05) :998-1008
[7]   A new control method for 400-Hz ground power units for airplanes [J].
Jensen, UB ;
Blaabjerg, F ;
Pedersen, JK .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2000, 36 (01) :180-187
[8]  
Kieferndorf F., 2010, 2010 International Symposium on Power Electronics, Electrical Drives, Automation and Motion (SPEEDAM 2010), P1718, DOI 10.1109/SPEEDAM.2010.5542049
[9]  
KUSKO A, 1990, CONFERENCE RECORD OF THE 1990 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETINGS, PARTS 1 AND 2, P1044, DOI 10.1109/IAS.1990.152313
[10]   Multiple-Loop Digital Control Method for a 400-Hz Inverter System Based on Phase Feedback [J].
Li, Chen ;
Ji, Shi-ming ;
Tan, Da-peng .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (01) :408-417